Plan Number: S04-051
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S04-051
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2007 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S04-051
Gracious Estates
Final Plat

TRANSMITTAL DATE: June 22, 2007

DUE DATE: July 17, 2007

COMMENTS:

The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.



If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960.

KAA S:\zoning review\karol\planning\cdrc\finalplat\S04-051fpr.doc
07/06/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-051 GRACIOUS ESTATES/REVISED FINAL PLAT
DATE: July 13, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

ON FINAL MYLAR:

1.) Change Wildlife Drive to Wild Life Drive (2 words) on Sheet Index.
2.) Label Silverbell Road on Sheet Index.
3.) Change Sheets 5 & 19 to 5 & 10 on Sheet Index.

NOTE:

1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.





jg
07/06/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-051 GRACIOUS ESTATES/REVISED FINAL PLAT
DATE: September 19, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.





***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***




jg
07/12/2007 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Subject: Gracious Estates
Lots 1-30
S04-051

TEP has received this e-mail of sheet 1 of the final plat for Gracious
Estates. The dedication shown on this sheet can be approved. TEP
approves this final plat.

Liza Castillo, Right of Way Agent
Land Management
Tucson Electric Power Co.
Unisource Energy Gas & Unisource Energy Electric
PH: (520) 917-8745
RightFax: (520) 545-1416
lcastillo@tep.com <mailto:lcastillo@tep.com>

-----Original Message-----
From: Becky Hammond [mailto:rhammond@eectuc.com]
Sent: Thursday, July 12, 2007 3:17 PM
To: Castillo, Liza
Subject: S04-051



Liza,



On our submittal of the final plat for Gracious Estates you posted a
denial due to us not addressing your previous comment. We have
corrected the third paragraph of the dedication to address your comment.
Attached is a copy of the corrected cover sheet for your review. Is it
possible to have the denial changed if this meets with your approval?
Let me know if you have any questions or need anything further. Thanks
for your help.



Becky Hammond

Project Coordinator

Land Development Dept.

Engineering and Environmental Consultants, Inc.

4625 E. Ft. Lowell Road

Tucson, AZ 85712

Ph. 520.321.4625

Fax 520.321.0333

www.eec-info.com
07/12/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/13/2007 CDRC1 COT NON-DSD REAL ESTATE Denied >>> Andy Steuart 07/13/2007 10:07 AM >>>
S04-051 Gracious Estates: Resubmittal - CDRC - Final Plat Review - Concerning the easement w/in Lot 1:
-As shown, the easement would be dedicated as a public easement and the City does not accept this easement for the following;
--The easement is 20' wide and City standards are 24' wide for roadway.
--The proposed in/egress easement serves a private owner and as shown, the City would be responsible to maintain the easement corridor.

Request the easement be established by separate instrument for in/egress for the benefit to parcel 101-21-011B.
Request the easement be delineated with a broken line to show the easement is part of Lot 1.
07/30/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Patricia Gehlen; CDRC Manager
SUBJECT: Gracious Estates Final Plat Engineering resubmittal Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S04-051

SUMMARY: Engineering has reviewed the revised Final Plat package, including closure calculation sheets, the Agreement to Construct and Amendment to Trust, copy of the drainage report, title report, copy of unsigned CC&R's, and response letter and does not recommend approval of the Final Plat at this time. Address the following plat and assurances comments prior to resubmittal.

FINAL PLAT COMMENTS:
1) City of Tucson Development Standards (DS) Section No. 2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. For the third party trust, address the following:
a) Regarding the Agreement to Construct and the Amendment to Trust, assure that the title block verbiage for the description of the plat exactly matches wording on the assurance document (recitals/first pages and legal descriptions in the exhibits) to prevent delays/rejection from the legal office.
b) Add subdivision case number S04-051 to each page, including exhibits, of the Agreement to Construct and the Amendment to Trust.
c) For the Exhibit "B" of the AGREEMENT TO CONSTRUCT, add 'onsite' to required improvements for assurable item 8.
a) For this and future projects, please provide two 8½" by 11" location map sheets for assurance submittals that go to Mayor & Council.
d) Revise assurance package, address comments, compile the package, and then resubmit the revised assurance package with the resubmittal. Provide:
i) original copy of the signed AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST;
ii) original copy of the signed AMENDMENT TO TRUST / THIRD PARTY TRUST;
iii) assure that all exhibits are attached, and the case number "S04-051" is on the AGREEMENT TO CONSTRUCT and AMENDMENT TO TRUST;
iv) copy of the original Trust Agreement;
v) copy of a sample Warranty Deed;
vi) copy of the updated/current Title Report.
vii) Three copies of the 8 ½ x 11 location map
2) DS Sec.2-03.7.1.E: Address the remaining CC&R comments:
e) Assure that the descriptions of the common areas of the Final Plat title block match the CC&R's descriptions of the subdivision common areas in appendix, as well as the descriptions in the assurance paperwork.
f) Add easement maintenance verbiage to CC&R's: All erosion protection and revegetation in all easements shall be the responsibility of the Homeowners Association.
g) Add case number S04-051 to first sheet of CC&R's.
h) Provide page numbering for every and all pages of the CC&R's including appendix and update table of contents accordingly.
i) An original signed copy of the CC&R's will be required for Final Plat approval.
3) DS Sec.2-03.6.4.F: Provide additional surveyable ties between floodplain and intersecting lot lines or project boundary. One tie per lot provides minimal tie at individual lot grading review stage.
4) DS Sec.2-03.6.4.A: Clarify whether TDOT has accepted the slope easements as public maintenance. Otherwise label slope easements as Private Slope Maintenance Easements. Provide copy of TDOT correspondence for public slopes.
5) DS Sec.2-03.6.3.C: Clarify 4th paragraph in Dedication section on sheet 1 to reflect include private easements.
6) DS Sec.2-03.6.3.C: Provide contact name for the beneficiary section on sheet 1. Move beneficiary section below the dedication section.
7) DS Sec.2-03.6.5.B: Assure that all easements listed on the Schedule B of title report are clearly drawn, labeled with Book/page or Docket/page, and/or listed as a blanket easement, and/or labeled with accurate dimensions and bearings on the plat. For item 5 of schedule B, easement dkt.6876 pg.506, clarify limits of easement on sheet 5.
8) DS Sec.2-03.6.4.G: Designate corner lot 4 with a star symbols indicating access or general location of driveway away from intersection or adjacent access entrances.
9) DS Sec.2-03.6.5.C: Address the following boundary data and other survey comments:
a) On planview clarify and label distances and bearings between all boundary monuments as measured (M) or calculated (C) or recorded (R).
b) DS Sec.2-03.6.5.C.3: Provide closure sheet for project boundary with error calculation. Only individual lot closures were provided.
c) DS Sec.2-03.6.4.G: Provide survey data by describing with bearings and distances on planview the ingress/egress easement at north side of lot 1.
d) DS Sec.2-03.6.5.C.4.a: All boundary monumentation must be labeled as "found" or "set." Fully describe and show all markings on found monuments. Provide information for three boundary corners.
e) DS Sec.2-03.2.3.A: Label the basis of bearing on sheet 1 planview.
10) DS Sec.2-03.6.2.E: On sheet 1, provide lot numbers and add a general note: "Prior to issuance of any building permit, a Flood Plain Use Permit may be required for Lots ____."
11) DS Sec.2-03.6.2.F: Since the property is subject to the requirements of the Hillside Development Zone, add as a general note to sheet 1: "Prior to the issuance of any building permits, Hillside Development Zone approval is required for all lots."
12)
13)

Submit revised Final Plat, revised assurances, title report, revised CC&R's, TDOT documentation, and response letter. The next submittal should address all the above items. If you have questions, call me at 837-4934.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
07/31/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES
***REVISED***

September 13, 2007
Joe Riojas
Engineering and Environmental Consultants, Inc.
4625 East Fort Lowell Road
Tucson, Arizona 85712

Subject: S04-051 Gracious Estates Final Plat

Dear Joe:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

(2) Title reports current within the last thirty (30) days.
(1) Executed Final Plat Double Matte Océ or Photo Mylar.
(1) * Check in the amount of $8.50 per plat page for Mayor & Council distribution made payable to the local print company of your choice or provide an account number to charge.
(1) * Check in the amount of $55.00 per plat page for recorded plat distribution made payable to the local print company of your choice or provide an account number to charge.
(1) Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a $4.00 handling fee, along with CC&R fees if applicable. CC&R fees are $9.00 for the first 5 pages and $1.00 for each additional page.
(1) Executed and notarized CC&R's document (if applicable).

*Please do not combine the checks for the printing charges. They are processed at different times and require separate checks. An account number is also acceptable and you can include this information on your transmittal sheet when submitting the above listed items.

Assurances (if applicable) must be reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5-6 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Prior to submitting the mylars to the CDRC office, they must be reviewed and approved by Pima County Addressing and City of Tucson Real Estate. Approvals must be written (E-mail is sufficient).

Should you have any questions, please call me at 837-4919.

Sincerely,

Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/