Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S04-036
Parcel: Unknown

Address:
10249 E RITA RD

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S04-036
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/24/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/25/2004 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-036 SHOPPING CENTER AT RITA RANCH/FINAL PLAT
DATE: March 25, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***












jg
04/05/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: SHOPPING CENTER @ Rita Ranch
5 Lots
S04-036

The Final Plat for the subject project will meet this Company's easement requirements.
Please forward any resubmittals of the final plat to this office.

Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission.




Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Pager: (520) 218-6565
Fax: (520) 917-8400
04/12/2004 DAN CASTRO ZONING REVIEW Approv-Cond COMMENTS
CODE SECTION/ DEVELOPMENT STANDARD

The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements.

1. This final plat has been assigned subdivision case number S04-036. Please note the case number in the lower right corner of each sheet on all plans.


If you have any questions about this transmittal, please call Dan Castro at (520) 791-5608.
04/13/2004 LAITH ALSHAMI ENGINEERING REVIEW Denied SUBJECT: Shoppes at Rita Ranch
S04-036, T15S, R15E, SECTION 23

RECEIVED: Final Plat on March 24, 2004

The subject Final Plat has been reviewed. The following comments are offered:

1. Provide the S(YR)-________ subdivision case number as required by D.S. 2-03.6.1.K.
2. Add "I further certify that this plat was prepared under my direction" to the "Certification of Survey" statement (D.S.2-03.6.3.A).
3. Add the BENEFICIARY block on the first sheet (D.S. 2-03.6.3.C).
4. Show no-vehicular access easements where applicable (D.S.2-03.6.4.H).
5. Show the detention/retention areas in a surveyable and readily retraceable manner (D.S.2-03.6.4.I).
6. In order to expedite the plat review and approval, provide the boundary survey and closure calculations report in accordance with D.S. 2-03.6.5.C.3.
7. Common Areas are addressed on page 2 of the "Restrictions and Easement Agreement", however, the Common Areas are not shown on the Plat. Additionally, it appears that the 30 foot Scenic Corridor Buffer should be shown as a Common Area. Address this issue and revise as needed.
8. Who is responsible for maintaining the drainage facilities?
9. Show cross drainage and access easements across the new lot line in order for the development to work as proposed and approved on the Development Plan. Revise Section "a" Grant of Easement on page 7 of the "Restrictions and Easement Agreement" to include the cross drainage easement.
10. It is not clear in the "Restrictions and Easement Agreement" who would maintain the Common Areas After the Developer has completed the project and it is turned over to the new owners.
11. Revise the "Subdivision Case No." on the first page of the Assurances.
12. The Assurance package is missing all the relevant exhibits and it does not appear to be complete.
13. The "Letter of Credit" (LOC) amount is not shown on the second page of the Assurances. Please be advised that the LOC amount should be based on an approved cost estimate for the required work.

If you have any questions, I can be reached at 791-5550 or lalsham1@ci.tucson.az.us

SUBMITTAL REQUIRED: Revised Final Plat, Restrictions and Easement Agreement, and Assurances
04/13/2004 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond April 13, 2004

TO: Steve Gregor
Gregor Engineering, Inc.

THRU: Craig Gross
City of Tucson Development Services

FROM: Dickie Fernández, E.I.T.
Development Review Division (Wastewater)

SUBJECT: Shoppes at Rita Ranch Lots 1-5
Final Plat - 1st Submittal
S04-036

The above-referenced project has been reviewed on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use:

ALL SHEETS. Add the subdivision plat case number, S04-036, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

This project is directly related to Shopping Center NWC Rita and Houghton Road (D02-038) for which a private Sewer Service Agreement was prepared and executed. Project S04-036 will follow the terms and conditions set forth in said private Sewer Service Agreement.

Revise the 2nd paragraph within the Dedication to read

“COMMON AREAS AS SHOWN HEREON ARE RESERVED FOR THE PRIVATE USE AND CONVENIENCE OF ALL OWNERS OF PROPERTY WITHIN OF THIS SUBDIVISION AND ARE GRANTED AS EASEMENTS TO PIMA COUNTY AND ALL UTILITY COMPANIES FOR THE INSTALLATION AND MAINTENANCE OF ABOVEGROUND AND UNDERGROUND UTILITIES, PUBLIC SEWERS AND DRAINAGEWAYS.

TITLE TO THE LAND OF ALL COMMON AREAS SHALL BE IN VESTED IN AN ASSOCIATION OF INDIVIDUAL LOT OWNERS AS ESTBLISHED BY COVENANTS, CONDITIONS AND RESTRICTIONS RECORDED IN DOCKET _______ AT PAGES ________, IN THE OFFICE OF THE PIMA COUNTY RECORDER. THIS ASSOCIATION WILL ACCEPT RESPONSIBILITY FOR CONTROL, MAINTENANCE, AND LIABILITY FOR THE PRIVATE STREETS, DRAINAGEWAYS AND PRIVATE SEWERS WITHIN THE SUBDIVISION.”

Subject to the above conditions, this project is hereby approved.

If you wish to discuss the above comments, please contact me at 740-6947.





Dickie Fernández, E.I.T.
Development Review Division (Wastewater)

Copy: Project

DF/df
04/23/2004 DOROTHY ROBLES COT NON-DSD REAL ESTATE Approved no objection.
04/23/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved no comments