Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S04-033
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S04-033
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/23/2004 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-033 PEPPER VINER AT RITA/REVISED TENTATIVE PLAT
DATE: June 22, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Change lots 1-48 to lots 1-47 on all Title Blocks.















jg
06/24/2004 DAN CASTRO ZONING REVIEW Approved
06/29/2004 LOREN MAKUS ENGINEERING REVIEW Approved DATE: June 29, 2004

To: Craig Gross
Planning Administrator
FROM: Loren Makus
Engineering Division

SUBJECT: Pepper-Viner at Rita
Tentative Plat S04-033 (Second Review)
T15S, R15E, Section 25

RESUBMITTAL REQUIRED: Tentative Plat and Drainage Report.

The Tentative Plat (TP) and Drainage Report (DR) cannot be approved as submitted. The following review comments must be addressed prior to the next submittal.

Tentative Plat:

1. As proposed, lots 29 through 41 are in violation of the differential grading requirements of the grading ordinance. Revise the proposed finish grades or provide the required justifications and approvals from adjacent property owners, as outlined in the ordinance. (Section 13 of Chapter 36 of IBC2000)
2. As previously commented, revise the street layout so that the corners meet the requirements of Figure 22 in Development Standard 3-01.10.
Drainage Report:
3. As previously commented, provide results of percolation tests showing that the retained volume will be disposed of within 12 hours. (Stormwater Detention/Retention Manual 3.5.1.3.a.)

A Stormwater Pollution Prevention Plan will be required when the Grading Permit is issued.
Submit a revised Tentative Plat, a revised Drainage Report and a soils report. Include a detailed response letter, detailing how each comment has been addressed.
If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus
Senior Engineering Associate
06/29/2004 LOREN MAKUS ENGINEERING REVIEW Approved All of the issues for Engineering have been met.
07/01/2004 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this T.P.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
07/01/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved COMPREHENSIVE PLANNING TASK FORCE COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-033 Pepper-Viner at Rita 06/30/04

(X) Tentative Plat
() Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Esmond Station

GATEWAY/SCENIC ROUTE: No

COMMENTS DUE BY: 4/14/04

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(X) No Additional Comments - Complies With Planning Comments Submitted on: 4/14/04 and meeting of 5/13/04
07/12/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
07/12/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond July 12, 2004

TO: James King, Rick Engineering Company

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Pepper Viner at Rita, Lots 1-48 and Common Areas A-C
- Submittal
S04-033


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Sheet 1: No off-site public sewers will need to be built for this project. Delete General Note 13.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

Copy: Project