Plan Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Plan Number - S04-033
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/18/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/18/2004 | JIM EGAN | COT NON-DSD | FIRE | Approved | The Tentative Plat is approved March 18, 2004. |
| 03/19/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-033 PEPPER-VINER AT RITA/TENTATIVE PLAT DATE: March 18, 2004 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Delete all street directions on pg. 2. Change “East Rita Road” to Rita Ranch Road on pg. 2. Change “Cascade way” to Drive on pg. 2. Label approved interior street names on Final Plat. |
| 03/25/2004 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | NO COMMENT S04-033 RICK ENGINEERING CO PEPPER-VINE AT RITA |
| 03/26/2004 | FRODRIG2 | COT NON-DSD | ENVIRONMENTAL SERVICES | Approved | All lots can be serviced from the front of the respective lots be Environmental Services. |
| 04/01/2004 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | April 1, 2004 TO: James King Rick Engineering THRU: Craig Gross City of Tucson Development Services FROM: Dickie Fernández, E.I.T. Development Review Division (Wastewater) SUBJECT: Pepper Viner at Rita Lots 1-48 and Common Areas A-C Tentative Plat - 1st Submittal S04-033 The above-referenced project has been reviewed on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use: This project will be tributary to the Roger Road Wastewater Treatment Facility via the Southeast Interceptor. Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. Contact Robert Decker, PCWWM Planning Services, at (520) 740-6625 regarding this matter. ALL SHEETS. Add the subdivision plat case number, S04-033, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers. Based on our evaluation, this project would qualify for Participating sewer connection fee rates. Based on the number of lots, a Sewer Service Agreement will be prepared during the Final Plat process. SHEET 2. Include all existing sewer information within 100 feet of the project boundaries. For sewer lines, include sewer size and Pima County plan number. For manholes, include manhole number, rim elevation and invert elevation. The current Pima County plan number within the layout is not accurate, please revise to show the existing sewer line to be G-99-175. Furthermore, this existing sewer line extends beyond the limits shown on the layout. SHEET 2. Eliminate manhole 1. Connect proposed sewer from manhole 2 directly to existing public sewer G-99-175. SHEET 2. Label manhole 3 to include a watertight lid, due to this manhole being within the path of the drainageway entrance. A complete set of revised bluelines, and a response letter, addressing these comments is required. Additional comments may be made during the review of these documents. The next submittal of this project will be the 2nd submittal. The review fee is $50.00 per revised sheet for the second submittal. The second submittal will include 2 revised sheets and a check for $100.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. If the number of revised sheets changes, please adjust the review fee accordingly. If you wish to discuss the above comments, please contact me at 740-6947. Dickie Fernández, E.I.T. Development Review Division (Wastewater) Copy: Project DF/df |
| 04/05/2004 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: PEPPER VINER @ RITA Lots 1-48 S04-033 Tucson Electric Power Company (TEP) has no objection to the City of Tucson tentative plat dated March 16, 2004. The preliminary point where TEP will serve this project is from the existing facilities to the west of this subdivision, proceeding through the interior of the subdivision. Enclosed is a copy of TEP's facility map showing the approximate location and unit numbers of the existing facilities. TEP will provide a preliminary electrical design on the Approved Tentative Plat within fifteen (15) working days upon receipt of the plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Should you have any questions, please contact me at (520) 917-8479. Liza Castillo Land Management Tucson Electric Power Company lcastillo@tep.com Office: (520) 917-8479 Pager: (520) 218-6565 Fax: (520) 917-8400 |
| 04/05/2004 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 RICK LYONS ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: April 2, 2004 RE: Assessor’s Review and Comments Regarding Tentative Plat S04-033 Pepper-Viner at Rita T151525 (141-17) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. Please add the bearings for the lot lines, the dimensions and bearings for the street centerlines and the complete curve data to the final plat. If there are any questions, please contact Susan King at 740-4391. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan C. King |
| 04/13/2004 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is March 17, 2004. 2. This plat has been assigned subdivision case number S04-033. Note the subdivision case number in the lower right corner of each sheet on all plans. (D.S. 2-03.2.2.B.1) 3. Under general note 16, revise "Planning Director" to "Development Services Department Director." (LUC 3.6.1.4.A.5) (D.S. 2-10.3.1.D) 4. Label and dimension perimeter yard setback lines on sheet 2 of 2. (D.S. 2-10.3.1.A) 5. Provide typical plot plan layouts for a corner lot, an interior lot, and a lot affected by the perimeter yard and street yard setback. These typicals are to be fully dimensioned and are to be drawn at a larger scale than the tentative plat. (D.S. 2-10.3.1.B) 6. Barrier-free accessibility must be provided to twenty-five percent of the ground floor units and all common areas within the project. Indicate how this accessibility is to be provided, and add a detail to the plat showing the accessibility. (D.S. 2-10.3.1.D) 7. The Final Plat may not be approved until the CC&R's are reviewed and approved by the Zoning Review Section. The CC&R's must meet criteria listed in L.U.C. 3.6.1.5. (D.S. 2-10.3.2.E) 8. All requested revisions must be made to the plat, Landscape and NPPO plans. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 04/16/2004 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | Add the CDRC case # to all plan sheets. Submit any revised plans for review. |
| 04/19/2004 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: April 19, 2004 To: Craig Gross Planning Administrator FROM: Loren Makus Engineering Division SUBJECT: Pepper-Viner at Rita Tentative Plat S04-033 (First Review) T15S, R15E, Section 25 RESUBMITTAL REQUIRED: Tentative Plat and Drainage Report. The Tentative Plat (TP) and Drainage Report (DR) cannot be approved as submitted. The following review comments must be addressed prior to the next submittal. Tentative Plat: 1. Provide general cross sections at boundaries showing change of grades and showing how proposed grades match existing grades inside the property lines. Clarify that there will be no cut or fill slopes within two feet of the site boundary per Section 14 of Chapter 36 of IBC 2000. 2. As proposed, lots 29 through 41 are in violation of the differential grading requirements of the grading ordinance. Revise the proposed finish grades or provide the required justifications and approvals from adjacent property owners, as outlined in the ordinance. (Section 13 of Chapter 36 of IBC2000) 3. Provide details for all outlet structures. (DS 2-03.2.4.L.2) 4. Provide proposed ground elevation at different points on each lot or provide typical lot grading details. Also show proposed elevations in common areas. (DS 2-03.2.4.L) 5. Clarify the existing spot elevations in lot 41. 6. Show and label all existing and proposed utility easements. Include a description of the purpose of each easement and whether it is public or private. Include pipe sizes for each applicable utility. (DS 2-03.2.4.J) 7. Revise the street layout so that the corners meet the requirements of Figure 22 in Development Standard 3-01.10 Drainage Report: 8. The tentative plat for Richmond American Homes at Rita Ranch and the Tentative Plat for Rita Reserve both show an existing Q100 of 39.5 cfs along the north side of Rita Road, impacting the 36 inch rcp culvert under Rita Reserve Way. Address the discrepancy in the revised drainage report. 9. Provide results of percolation tests showing that the retained volume will be disposed of within 12 hours. (Stormwater Detention/Retention Manual 3.5.1.3.a.) 10. Show the locations and types of security barriers around the detention/retention basin. Discuss how the proposed basin complies with the landscaping and grading guidelines of the Retention/Detention Manual. (Standards Manual for Drainage Design and Floodplain Management 2.3.1.6.A) A Stormwater Pollution Prevention Plan will be required when the Grading Permit is issued. Submit a revised Tentative Plat, a revised Drainage Report and a soils report. Include a detailed response letter, detailing how each comment has been addressed. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus Senior Engineering Associate |
| 04/20/2004 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: April 20, 2004 TO: Ferne Rodriguez, Development Services FROM: Glenn Hicks, Parks and Recreation SUBJECT: CDRC Transmittal, S04-033 Pepper-Viner at Rita: TP CC: Craig Gross, Development Services Staff has reviewed the tentative plat and has no comments. Please feel free to call me at 791-4873 x 215 if you have any questions. |
| 04/20/2004 | CRAIG GROSS | OTHER AGENCIES | PIMA ASSN OF GOVTS | Passed | |
| 04/20/2004 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | COMPREHENSIVE PLANNING TASK FORCE COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S04-033 Pepper-Viner at Rita 04/19/04 (X) Tentative Plat () Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: NEIGHBORHOOD PLAN: Esmond Station GATEWAY/SCENIC ROUTE: No COMMENTS DUE BY: 4/14/04 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies (X) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (X) Resubmittal Required: (X Tentative Plat () Development Plan (X) Landscape Plan () Other REVIEWER: msp 791-4505 DATE: 4/14/04 Urban Planning and Design Comments S04-033 Pepper-Viner at Rita Tentative Plat April 14, 2004 Staff offers the following comments: An RCP (Residential Cluster Project) shall comply with applicable neighborhood/area plan. The proposed RCP is located within the Esmond Station Area Plan and the following policies apply. LAND USE POLICIES RESIDENTIAL Policy 1: Design residential development to create viable neighborhoods. A. Design circulation to keep through traffic on major streets. B. Promote clustering and design flexibility in residential developments by encouraging the use of planned unit developments1, zero lot line, and lot development options where such design will foster community feeling and preserve drainageways and other natural features. E. Mid-urban residential developments are generally appropriate along and with direct access to arterial streets. H. Require pedestrianway systems that integrate, rather than segregate, residential developments and furnish a connection with public pedestrianways. I. Require pedestrianways in, between, and around all neighborhood facilities, e.g., schools, parks, and commercial centers. Policy 2: Ensure the compatibility of new residential development with existing and committed land uses and uses which would be permitted on adjacent parcels by their existing zoning classifications. DAVIS-MONTHAN AIR FORCE BASE Subgoal Policy 1: Ensure compatibility of new development with existing and future operation of Davis-Monthan Air Force Base. B. Request Davis-Monthan Air Force Base Community Planning staff to review development plans proposed in the Esmond Station area. C. When proposed development is affected by Davis-Monthan Air Force Base operations, require a "fair disclosure statement" be part of any development plans, final plats, informational brochures, and sales/rental agreements, indicating that certain types of military air and ground training activities occur at Davis-Monthan Air Force Base. Policy 2: Ensure compatibility of base operations with existing and potential adjacent development Implementation Techniques A. Request Davis-Monthan Air Force Base Community Planning to review plans of future base expansion or changes for compatibility with off-base development. D. Proposed lower density single-family developments must provide access and maneuvering onto local streets rather than directly onto collectors or arterials. Policy 2: Provide adequate access to all properties. A. Require design of neighborhood traffic circulation systems in conjunction with new development and rezoning requests. Policy 3: Provide a street system as identified in the Major Streets and Routes Plan. A. Ensure implementation of Major Streets and Routes Plan policies in street design and gateway design standards for development along the routes so designated. Discussion: Esmond Station policies provide policy that seeks compatibility with the Davis-Monthan Air Force Base, and adjacent residential developments in reference to scale, mass and setbacks. Plan policy supports pedestrian and vehicular connectivity within neighborhood boundaries. The proposed tentative plat proposes a single-point of access for the entire 48 lots design with no connectivity to the adjacent residential development to the west. In addition the tentative plat design provides no access for potential future residential development on adjacent State Land, located to the north and east. Staff recommends based on Plan policy to provide vehicular and pedestrian access with the adjacent residential development to the west. Vehicular and pedestrian access should connect with Rita Reserve Way, a local street located adjacent to the western perimeter of this project. The common areas need to be identified with their primary use such as recreational, drainage, open space etc. Such as common area “C” needs to identify on the tentative plat as a common area for open space/recreational uses. Davis-Monthan Air Force Base is within the vicinity of this development. Although the site is outside of the 65-ldn requirements, potential buyers should be aware of the Air Base presences. Bases on the analysis above, staff offers the following recommendations: 1. Please add to the tentative plat general notes a disclosure statement on the proximity of the Davis-Monthan Air Force Base. The disclosure statement shall further indicate the Davis-Monthan Air Force Base is a military installation where governmental approved activities occur which include military training. 2. Please written documentation and comments, that Davis-Monthan Air Force Base, Planning staff has reviewed this proposed tentative plat. 3. Please revise tentative plat to provide a secondary vehicular access point that connects with Rita Reserve Way, an adjacent residential local street along the western perimeter of this project. 4.Please revise tentative plat to provide a secondary vehicular access point that connects with the adjacent State Land property. Connection may be along the northern or eastern perimeter of this project. 5. Please revise landscape plan to identify within common area “C,” the bench (typ) located adjacent to lot 7. 6. Please revise landscape plan to provide an all-weather surface pedestrian path of 5 feet wide minimum, which connects all the proposed amenities within common area “C” with the sidewalk system. 7.Provide at the discretion of the initial property owners on lots 1 through 8, 10 through 12 a pedestrian access point along the rear property lines on each of these lots. Pedestrian access point to be designed to provide privacy, safety and ability to have eyes on the recreational area. |
| 04/20/2004 | DOROTHY ROBLES | COT NON-DSD | REAL ESTATE | Approved | no objection. |
| 04/20/2004 | DALE KELCH | COT NON-DSD | TRAFFIC | Denied | Traffic Engineering REJECTS this T.P. 1. Add a general note to read "All non-signalized intersection street names must have E-W block number addresses for E-W roadways and N-S block number addresses for N-S roadways." 2. How do lots 20/21 and 29/30 meet the driveway spacing requirements of Tucson City Code chapter 25 section 38? Is this satisfied by the private access easement? Will these lots have a shared driveway? D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |