Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S04-032
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S04-032
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/07/2004 JOE LINVILLE LANDSCAPE REVIEW Approved
07/07/2004 LAITH ALSHAMI ENGINEERING REVIEW Approved SUBJECT: Tanque Verde Center
S04-032, T13S, R15E, SECTION 32

RECEIVED: Tentative Plat and Drainage Report on July 6, 2004

The subject project has been reviewed. The Drainage Report is generally acceptable for Tentative Plat purposes, however comments 4 and 5 from our response letter dated May 20, 2004 have not been addressed satisfactorily. The following two comments have to be properly addressed with the Grading Plan submittal:

1. The proposed western detention basin appears to be very close to lot #15. Determine the basin setback line based on the Soils Report recommendations and verify that the basin location is appropriate.
2. The detention/retention basin bottoms must be graded to provide positive drainage to prevent nuisance ponding. Bleed pipes are acceptable for retention basin discharge as long as they do not drain directly onto a street and they do not cause drainage problems downstream. Bleed pipes can not be smaller than 6" in order to facilitate maintenance, however, drainage can be controlled at the pipe entrance by a cap with a hole that has less than a 6" diameter.

The Tentative Plat is acceptable and it is hereby recommended for approval pertaining to Engineering and Floodplain. Please be advised that additional information may be required on the Grading Plan
07/09/2004 JCLARK3 ENV SVCS REVIEW Approv-Cond Enclosure detail needs to be revised to show 10' clear area and side wall protection.
07/19/2004 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this T.P.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
07/20/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT URBAN PLANNING AND DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-032 Tanque Verde Center 07/20/04

(x ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C12-96-39, C9-95-29

NEIGHBORHOOD PLAN: Sabino Canyon - Tanque Verde Area Plan

GATEWAY/SCENIC ROUTE: N.A.

COMMENTS DUE BY: 07/19/2004

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
( x) No Additional Comments - Complies With Planning Comments Submitted on: 05/26/04
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: E. Anderson 791-4505 DATE: 07/15/2004
07/30/2004 DAVID RIVERA ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Plans Coordination Office
Development Services Department

PROJECT: S04-032
Tanque Verde Place, Lots 1-58 and Common Areas "A", "B" and "C"
Tentative Plat

FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner
Zoning Review Section

TRANSMITTAL: July 30, 2004

DUE DATE: July 20, 2004

COMMENTS:

The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.

If you have any questions about this transmittal, please call David Rivera at (520) 791-5608.







C:\planning\cdrc\tentativeplat\S04032tpa.doc
08/02/2004 TIM ROWE PIMA COUNTY WASTEWATER Approved August 2, 2004

TO: Chuck Martin, Rick Engineering Company

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Tanque Verde Center, Lots 1-58 and Common Areas A-C
- Submittal
S04-032


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


We have sent to your office under separate a Sewer Service Agreement for the proposed number of wastewater fixture unit equivalents. Once the three originals of the Agreement have been signed by the Owner of Record, and notarized, they must be returned to Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the development plan / tentative plat.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan / tentative plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

Copy: Project
08/02/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
08/02/2004 TIM ROWE PIMA COUNTY WASTEWATER Approved This office has received the three signed and notarized originals of the
Sewer Service Agreement required for the above referenced tentative plat
/ development plan. All of the conditions of PCWMD's conditional
approval for this tentative plat / development plan have now been met.

Tim Rowe, P.E., Civil Engineer
Development Review Division - Wastewater
520-740-6563