Plan Review Detail
Review Status: Completed
Review Details: REVISN TENT PLAT & CORE RESUB
Plan Number - S04-032
Review Name: REVISN TENT PLAT & CORE RESUB
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/12/2008 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | Laith Alshami, Engineering and Floodplai Review, 11/12/2008, TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Tanque Verde Place S04-032, T13S, R15E, SECTION 32 RECEIVED: Tentative Plat and Drainage Report on October 30, 2008 The subject project has been reviewed. The revised Tentative Plat/Development Plan is recommended for a conditional approval, pertaining to Engineering and Floodplain Review, subject to the following: 1. Provide, on the Tentative Plat/Development Plan, the numbers of all approved DSMR's for this project. RESUBMITTAL REQUIRED: Revised Tentative Plat/Development Plan |
| 11/14/2008 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S04-032 (Revised tentative plat/development plan) Tanque Verde Place lots 1-4 7-58 and Common Areas A-1 - A-3, B-1 - B-4, C-1 - C-2 Tentative Plat TRANSMITTAL DATE: 11/07/2008 DUE DATE: 11/14/2008 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. List the DSMR case number in the lower right corner next to the title block of all plan sheets. List as a general note the DSMR case number, date of approval, and conditions of approval if any. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\tentativeplat\S04032revtp3.doc |
| 11/19/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 19, 2008 Chuck Martin Rick Engineering Company 1745 East River Road, Suite 101 Tucson, Arizona 85718-7633 Subject: S04-032 Tanque Verde Place Revised Development Plan/Tentative Plat Dear Chuck: The above referenced plan has been CONDITIONALLY APPROVED by the Community Design Review Committee, subject to the revisions required on the bluelines per the on-line comments. Please submit the following documents for sign-off: 1 Blueline set of the Plat, Landscape Plan and NPPO. Please include applicable sheets from any other concurrent reviews. 2 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your bluelines to the CDRC office for sign-off approval. Your printing company will deliver the stamped blueline set to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 tp-approved |