Plan Number: S04-028
Parcel: Unknown

Address: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S04-028
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/18/2005 LOREN MAKUS ENGINEERING REVIEW Denied DATE: February 18, 2005
TO: Craig Gross; CDRC Coordinator
SUBJECT: Acacia Lane Tentative Plat Engineering Review
REVIEWER: Loren Makus
ACTIVITY NUMBER: S04-028

SUMMARY: The Tentative Plat, Landscape Plan, and Drainage Report were reviewed by Engineering on February 18, 2005. Engineering does not recommend approval at this time. The Drainage Report was reviewed for Tentative Plat purposes only.


TENTATIVE PLAT COMMENTS:
1) Revise the Tentative Plat to show dedication of the future right-of-way.


Submit the revised Landscape Plans, and revised Tentative Plat. The next submittal should address all the above items. To set up a meeting, call me at 791-5550, extension 1161.

Loren Makus, EIT
Senior Engineering Associate
Engineering Section
Development Services
02/22/2005 DAN CASTRO ZONING REVIEW Approv-Cond The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

1.
Comply with Engineering comments regarding the correct labeling of right-of-way dimensions.

If you have any questions about this transmittal, please call Dan Castro at (520) 791-5608.
02/23/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the landscape plans to designate decomposed granite in the adjacent right of way area along Drexel Road. LUC 3.7.2.7, LUC 3.7.2.4.A.3, DS 2-06.5.2.C

2) Revise the tentative plat and the landscape plans to show the common areas consistently. DS 2-03.2.4.C
Revise the title block if necessary to include common area(s).
02/28/2005 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this TP:

1. 1. The symbol used for the new no parking signs is incorrect. The symbol as depicted is for existing signs. Use the correct symbol for new signs IAW SDPI SD 100. This is the 2nd time this same comment has been made. The signs as depicted still indicate existing signs. Please correct.

2. 2. The driveway spacing between lots 7/8 appear to not meet the spacing requirements of Chapter 25 of Tucson City Code. Minimum spacing is 12'. The consultant has corrected the discrepancy between lots 6/7 but the spacing between lots 7/8 appears to only be 5'. The requirements is 12'. Please correct.


D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
02/28/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed