Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S04-026
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S04-026
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/20/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/24/2005 JCLARK3 ENV SVCS REVIEW Approved If the most eastern enclosure of #2 & #7 is designed at 30 degree angle from the north then the entire complex can be serviced from a single pass of the collection vehicle. Recommend that this be considered.
01/31/2005 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, 01/31/2005

SUBJECT: SEC Houghton/Valencia
S04-026, T15S, R15E, SECTION 24

RECEIVED: Tentative Plat and Drainage Report on January 20, 2005

The subject project has been reviewed. We offer the following comments:

Drainage Report:

The Drainage Report is acceptable for Tentative Plat purposes. The following information should be provided in a revised drainage report with the Grading Plan submittal.

1. Address erosion control requirements at the proposed detention basin inlets, outlets and low flow pipes. Provide the design calculations for the erosion control structures and show their locations, material and sizes on the drainage exhibits.
2. Show on the Grading Plan the erosion control structure at detention basin A2 bleed pipe outlet, within the proposed landscape area outside the 30' natural buffer area.
3. Size in the revised Drainage Report and show on the Grading Plan the required sidewalk/walkways scuppers to accommodate the 10-year flows including to roof drainage.

Tentative Plat/Development Plan:

The Tentative Plat/Development Plan is acceptable and it is recommended for approval pertaining to Engineering and Floodplain.

Please be advised of the following:

1. Add a general note to the Final Plat which addresses the proposed cross access easements and references the dedication information in the CC & R's.
02/04/2005 GLENN HICKS COT NON-DSD PARKS & RECREATION Denied DATE: February 04, 2005

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, S04-026 Houghton/Valencia: Resubmittal - Tentative Plat Review

CC: Craig Gross, Development Services


Due to maintenance considerations and/or a history of poor performance in streetscapes, the following landscape plants shown within the Houghton Greenway are not acceptable:
Hesperaloe funifera
Cassia artemisioides
Leucophyllum laevigatum
Salvia greggii

Native plants should be used. Acceptable plants include but are not limited to:
Larrea tridentata – Creosote
Baileya multiradiata – Desert Marigold
Penstemon parryi – Parry’s Penstemon
Yucca elata – Soaptree Yucca
Calliandra eriophylla – Fairy Duster
Psilostrophe cooperi – Paperflower

Any of the plants used in the Houghton Greenway landscaping between Poorman Rd and Bilby Rd. are acceptable.




Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
02/04/2005 DAN CASTRO ZONING REVIEW Denied COMMENTS
1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is March 3, 2005.

2. Tentative Plat may not be approved prior to SCZ review and approval.

3. Awaiting Traffic Engineering approval for previous comment regarding number of curb cuts.
Previous comment: Since this project is being developed as a "mixed use development", the project must comply with the criteria listed under the definition for "mixed use" under LUC Sec. 6.2.13. The number of curb cuts is limited to two (2) or less, unless a greater number is approved by the City Traffic Engineer or designee. Written approval shall be submitted indicating the proposed number of curb cuts for this project is acceptable.

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
02/08/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
02/08/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this TP/DP.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov