Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S04-026
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW

Plan Number - S04-026
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/29/2006 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S04-026
SEC Houghton/Valencia
Final Plat Resubmittal

TRANSMITTAL DATE: September 29, 2006

DUE DATE: October 23, 2006

COMMENTS:

The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements.




If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\finalplat\S04-026fpr.doc
10/09/2006 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 10/09/2006

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Houghton Crossings Office Condominium Park
Formerly "SEC Houghton/Valencia"
S04-026, T15S, R15E, SECTION 24

RECEIVED: Final Plat and CC & R's on September 26, 2006

The subject project has been reviewed and it can not be recommended for approval at this time. We offer the following comments (Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Tentative Plat where the revisions were made):

Final Plat:

1. The reviewer has not received a copy of the subject project assurances to verify that a "Beneficiary" Block is not needed on the Final Plat. Verify that a "Beneficiary" Block is not needed for this project (D.S. 2-03.6.3.C.).
2. According to the Title Report, the Easement recorded in Docket 2703, Page 223 is an electrical easement; not a gas easement as shown on the Plat below the words "Valencia Road". Ensure that the information in the Title Report and on the Final Plat match.
3. Easements #6 & #7, as Described in the Title Report, do not appear to be depicted on the Final Plat. It is difficult to determine that the easements do not affect the subject property without showing them. It is assumed that since the easements are included in the Title Report, they affect the project.
4. Provide the other documents and specify where in the CC & R's access arrangements are established. If the access arrangements have not been established as described, cross access easement between Lot 1 and the rest of the development is required (D.S. 2-03.6.4.K.).
5. The basis of bearing has been shown, but it appears that the subject development tie to the basis of bearing has not been shown. Verify compliance with the requirements of D.S. 2-03.6.5.A. & C.
6. Are there any measured distances and bearings between monuments in this development? Indicate which ones are measured as required by (D.S. 2-03.6.5.C.5).
7. Submit a copy of the Assurances package.

CC & R's

The CC & R's are acceptable pertaining to Engineering and Floodplain. We recommend including a copy of the "Drainage Structures Check List" as an exhibit to the CC & R's to help facilitate the Home Owner Association's maintenance responsibility.



RESUBMITTAL REQUIRED: Revised Final Plat and Assurances
10/23/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-026 SEC HOUGHTON/VALENCIA/REVISED FINAL PLAT
DATE: 10/23/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***





ES
10/31/2006 FRODRIG2 COT NON-DSD REAL ESTATE Denied S04-026 SEC Houghton/Valencia Resubmittal - CDRC Final Plat - Per legal description to Dkt./Pg. 11020/2761, request validation of locations of easements for wellsite and in/egress.
11/07/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved November 6, 2006

To: Laura Lohner, Stantec Consulting Inc.

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

Subject: Houghton Crossings Office Condominium Park Lot 1
Units 101 through 139, 201 through 212 and Common Elements “A” & “B”
Final Plat – 2nd Submittal, S04-026

The drawings for the proposed final plat of the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality and the Pima County Wastewater Management Department. This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the final plat as received by us on September 22, 2006.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval to Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above, please do not hesitate to contact me.

Sincerely,


Chandubhai C. Patel, P.E.
Telephone: (520) 740-6563

Copy: Project File
11/08/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

November 8, 2006

Kenneth D. Perry, PE
Stantec Consulting
201 North Bonita Avenue
Tucson, AZ 85745

Subject: S04-026 SEC Houghton/Valencia Final Plat

Dear Ken:

Your submittal of September 26, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

63 Copies Revised Final Plat (Engineering, Real Estate, DSD)

2 Copies Revised CC&R's (Engineering, DSD)

THIS FINAL PLAT MUST BE APPROVED BY MAYOR AND COUNCIL AND RECORDED BY JANUARY 25, 2007 OR IT WILL EXPIRE WITHOUT POSSIBILITY OF EXTENSION PER LUC 4.1.7.3.



Should you have any questions, please call me at 791-5608 ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 750-7470