Plan Number: S04-024
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - TENTATIVE PLAT REVIEW

Plan Number - S04-024
Review Name: REVISION - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/14/2006 KAROL ARAGONEZ ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: S04-024
Desert Point Estates
Tentative Plat Revision

TRANSMITTAL DATE: September 14, 2006

DUE DATE: October 9, 2006

COMMENTS:

The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550.

KAA S:\zoning review\karol\planning\cdrc\tentativeplat\S04-o24tpr.doc
09/27/2006 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond The Landscape Section recommends approval subject to City Engineer approval of the proposed construction regulated under the WASH Ordinance. A seperate application may be required per TCC 23A-51. Contact Patricia Gehlen for application information.
09/28/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved URBAN PLANNING AND DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-024 Desert Point Estates 09/28/06

(X) Tentative Plat
() Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-99-25

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: 10/09/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
(X) Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(x) No Additional Comments - Complies With Planning Comments Submitted on: 3/19/04








REVIEWER: msp 791-4505 DATE: 10/09/06
URBAN PLANNING AND DESIGN COMMENTS
10/17/2006 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: October 16, 2006

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, S04-024 Desert Point Estates: Tentative Plat Revision

CC: Craig Gross, Development Services


Approved.



Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
10/23/2006 JASON GREEN ENGINEERING REVIEW Denied DATE: October 23, 2006
SUBJECT: Engineering review of Desert Point Estates - Grading Plan Revision
TO: Sierra Pacific Homes, LLC
LOCATION: 6144 S Antrim Pl, T15S R14E Sec10, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: T04BU02558R (Grading Plan) and S04-024 (Tentative Plat)

SUMMARY: Engineering Division of Development Services Department has received the revised grading plan, revised Tentative Plat, W.A.S.H. Report, Letter of Understanding For Earp Wash Detention Basin and Desert Point Estates (Letter of Understanding), and revised SWPPP. Engineering has reviewed the revised grading plan, Tentative Plat, and SWPPP and does not recommend approval of the grading plan or Tentative Plat revisions at this time. The following items need to be addressed:


GRADING PLAN COMMENTS:

1) DS Sec.11-01.4.1.C.3: Provide a detail for the transition between the 16-foot scupper located at the end of Big Game Place and the proposed 10-foot spillway into the basin.
2) DS Sec.11-01.4.1.C.4: Revise Detail A on Sheet 4a to call out the correct Water Surface Elevation (WSEL) that is shown in the submitted drainage report.
3) Provide a signed copy of the Letter of Understanding with signatures from Pima County Regional Flood Control District, City of Tucson Department of Transportation, and Sierra Pacific Homes, along with Exhibits A, B, C, and D that are called out in paragraph 8 of the Recitals Section. Revise the Tentative Plat and Final Plat to reflect the loss of property and/or revised property lines.


TENTATIVE PLAT COMMENTS:

4) DS Sec.11-01.4.1.C.4: Revise Detail A on Sheet 4a of 5 on the Tentative Plat to call out the correct WSEL that is shown in the submitted drainage report. Also provide the property line on the detail.
5) Paragraph 4 in the Letter of Understanding under the recital paragraph states that Common Area "C" (Detention Basin 1) and Common Area "B" (Channels 1 and 2) are to be dedicated to Pima County. A revised Final Plat will be required with recordation documentation showing the dedication and that the lot lines of the original Final Plat have changed.
6) Revise the Title Block on Sheet 1 of the Tentative Plat to reflect the 20-foot wide sewer easement that falls within Common Area "A".


STORMWATER POLLUTION PREVENTION PLAN: The SWPPP does not meet the minimum requirements of the AzPDES Construction General Permit (CGP). Revise the SWPPP according to the following comment:

7) CGP Part IV.C.3.c: Identify on the SWPPP, Sheet 2a of 3, the temporary erosion control measures that are required at the weir outlet structure and low flow pipe within Detention Basin #3.
8) CGP Part IV.C.3.c: Identify on the SWPPP, Sheet 2a of 3, the temporary erosion control measures that are required at the upstream end of the scupper location at the end of Big Game Place.


GENERAL COMMENTS:

A revised Final Plat will be required after the dedication of property from Desert Point Estates to Pima County. The revised Final Plat must reflect the new lot lines and property boundaries. Contact CDRC for further processing questions.

Please provide a revised grading plan, Tentative Plat, signed Letter of Understanding, W.A.S.H. Report and SWPPP.

The revised grading plan, Tentative Plat, signed Letter of Understanding W.A.S.H. Report and SWPPP must address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Please include the Redlines at re-submittal.

Further comments may be generated upon resubmittal of the grading plan, Tentative Plat, signed Letter of Understanding (after being revised and recompiled), and SWPPP.

For any questions or to schedule a meeting, call me at 791-5550, extension 1189.




Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
10/27/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 27, 2006

Jason Morse
Castro Engineering
3580 West Ina, #200
Tucson, Arizona 85718

Subject: S04-024 Desert Pointes Estates RevisedTentative Plat

Dear Jason:

Your submittal of September 12, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

2 Copies Revised Tentative Plat (Engineering, DSD)

2 Copies Revised Grading and SWPP Plans (Engineering, DSD)

2 Copies Revised WASH Report (Engineering, DSD)

2 Copies Letter of Understanding (Engineering, DSD)


Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 293-2115