Plan Number: S04-004
Parcel: Unknown

Address:
3514 E GLENN ST

Review Status: Completed

Review Details: OTHER SUBDIVISION REVIEW

Plan Number - S04-004
Review Name: OTHER SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/26/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/27/2004 JIM EGAN COT NON-DSD FIRE Denied Provide a General Note on the plan stating:"On street parking shall be prohibited to provide minimum 20 feet wide, unobstructed, fire apparatus access. Approved fire lane signs shall be provided. Plans for Fire Lane shall be provided to Fire Department for approval of sign locations."
02/02/2004 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
S04-004
RICK BRIGHT ARCHITECT AIA INC.
GLENN DUPLEXES
02/09/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied From: "Castillo, Liza" <LCastillo@tep.com>
To: 'Craig Gross' <cgross1@ci.tucson.az.us>, 'Ferne Rodriquez' <frodrig2@ci.tucson.az.us>
Date: 02/06/2004 8:07:44 AM
Subject: GLENN DUPLEXES, S04-004

SUBJECT: GLENN DUPLEXES
S04-004

Tucson Electric Power Company (TEP) has reviewed the plans dated January 19,
2004. TEP is unable to approve the plans at this time. There are existing
electrical facilities within the boundaries of this project. In order for
TEP to approve the plans, the facilities and easement recording information
must be depicted on the plans.

Enclosed is a copy of a TEP facility map and the development plan showing
the approximate location of the existing facilities. There is an existing
pole on the east lot line that serves a home in the rear of this
development. All cost associated with the relocation of the facilities in
conflict will be billable to the developer.

Please resubmit two revised bluelines to the City of Tucson for TEP's
review.

Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Pager: (520) 218-6565
Fax: (520) 917-8400
02/10/2004 JIM TATE ENGINEERING REVIEW Denied TO: Craig Gross; CDRC Coordinator
DATE: February 10, 2004

SUBJECT: Engineering review of the Glenn Duplexes Subdivision Exception. The activity number is S04-004.

SUMMARY: The Subdivision Exception was received by Engineering on January 27 , 2004. Engineering has reviewed the received item and does not recommend approval of the lot split.

RESUBMITTAL REQUIRED: FINAL PLAT, SITE PLAN

SUBMITTAL REQUIRED: ASSURANCES, CC&Rs, DRAINAGE STATEMENT

GENERAL COMMENTS

1. Minor subdivision is required. Provide Final Plat. For Final Plat requirements see DS 2-03.6

2. Submit the Site Plan with the Final Plat.

3. A Drainage Statement is required. See Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 2.2.2, 2.1 The statement must include a discussion of offsite to onsite flows and onsite to offsite flows. Stormwater must be accepted and released from developments essentially at the same locations, and with the same magnitude, as encountered under existing conditions. SMDDFM, 12.5

4. Please include the Assurance Package with the Final Plat submittal. This package must include the original Third Party Trust, the original Amendment to Trust, a copy of the Trust Agreement, a copy of the Deed, and a recent Title Report.

5. Include a copy of the CC&Rs with the Final Plat submittal.

6. Please provide a copy of the boundary closure calculations with the Final Plat submittal.

7. A Grading Plan and Permit will be required. Proposed grading in excess of 5,000 yards is designated "engineered grading" and a soils engineering report is required with the Grading Plan submittal. IBC Chapter 36, Section 9. The Soils Report must also address the requirements detailed in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.2.6.

8. Proposed fills in excess of two feet above existing grade at any location in the outer one hundred feet of the developing site adjacent to residentially zoned property require the procedure outlined in IBC Chapter 36 Section13.1. This process must be complete prior to Grading Plan approval.

The next submittal must address the following items:

SITE PLAN COMMENTS

1. Change the title of the plan to "Minor Subdivision Site Plan".

2. Glenn is an MS&R street. Provide curb returns with a minimum radius of 25 ft. See Transportation Access Management Guidelines for the City of Tucson Table 5-2.

3. Glenn is an MS&R street. Minimum required sidewalk width is 6 ft.

4. Place a note on the plan that all roof downspouts will be routed under any adjacent sidewalk. Sidewalks must be flood free for up to the ten year event. DS 2-08.4.1.E

5. Solid waste can not access the dumpster. The turnaround must be designed according to DS 3-01 Figure 23. Contact John Clark at Environmental Services 791-3175 ext. 1136 for assistance with location of the dumpster.

6. Show drainage patterns, proposed finish floor elevations, and finish grades. DS 2-02.2.1.A.16

7. Show estimated cut and fill quantities. DS 2-02.2.1.A.17

8. Label curb and sidewalk on Glenn as existing or proposed.

9. Show existing contours at intervals not exceeding two feet. and/or spot elevations and Bench Mark including City of Tucson Field Book Number and Page. DS 2-02.2.1.A.21

10. Place the Subdivision Case No. (S04-004) on all sheets by the Title Block.

11. Place the drainage note specified in DS 2-03.2.2.C.1 on the plan.

12. Dedicate right of way on Glenn to the future MS&R width. DS 2-03.2.4.H

13. Provide proposed ground elevations at different points on each lot for reference to future grading and site drainage. DS 2-03.2.4.L

James C. Tate, P.E., CFM
Civil Engineer
02/19/2004 TIM ROWE PIMA COUNTY WASTEWATER Denied March 01, 2004

TO: Rick Bright, Rick Bright Architect AIA, Inc.

THRU: Craig Gross, City of Tucson Development Services

FROM: Tim Rowe, P.E., Development Review Engineer (representing
Pima County Wastewater Management and Environmental Quality)
Pima County Development Review Division

SUBJECT: Glen Duplexes, Lots 1-5
Subdivision Exception
S04-004



The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management (PCWWM) Department. This review letter may contain comments pertaining to the concerns of either Department. Separate review letters from PDEQ and PCWWM representatives will not be prepared for this project. The following comments are offered for your use:

1. This project will be tributary to the South Rillito West - South Line and the Roger Road Wastewater Treatment Facility. Per PCWWM Planning Services, there is currently treatment and conveyance system capacity in the existing downstream sewerage system for this development. Flow from this proposed project would not cause an flow of effluent quality limits to be exceeded. This response is not to be construed as a commitment for treatment or conveyance capacity allocation, but rather an analysis of the existing sewerage system as of this date. If conditions change between now and the time a formal Sewer Service Agreement is established between the owner of record and Pima County, the property owner may be required to augment the existing public sewerage system in order to provide adequate treatment and conveyance capacity for this project.

2. Based on our historical records for this property, this project would qualify for Participating sewer connection fee rates. However, a final determination of this status cannot be made until approval of the sewer construction plans and/or preparation of the sewer service agreement.

3. All Sheets: Add the subdivision exception case number, S04-004, to the title block of each sheet. This number should be shown larger or bolder than the cross reference numbers.

4. Show the sewer line in Glenn Street to which this project will connect, labeled with its size (18") and plan number (G-141).

5. Is the existing 4" House Connection Sewer (S) large enough to serve all of these duplexes? Show the slope of the HCS on the plan. In your response letter, indicate how many existing wastewater fixture unit equivalents will remain, how many new wastewater fixture unit equivalents are being proposed, and the total number of wastewater fixture unit equivalents that be discharging to the public sewer system through the existing 4" private sewer line.

Please note that 4" HCS with a slope of 2% may carry the flow from only 216 wastewater fixture unit equivalents per the Uniform Plumbing Code, and a 4" HCS with a slope of 1% may carry the flow from only 173 wastewater fixture unit equivalents.

If necessary to carry the flow, show a new 6" private sewer line running the length of the access and utility easement connecting to existing sewer line, G-141 at a new manhole in Glenn Street.

6. Provide one or more General Notes appropriate for the type of private sewer line (new or existing) that will be utilized.

7. Label the access and utility easement as a PRIVATE easement.

8. Provide an appropriate Dedication to grant the easements, per the COT CDRC’s standards for final plats. The responsibility for maintaining the private sewer lines must be clearly identified either in Dedication or in a General Note.

Please note: If a homeowners association is not being formed, an acceptable Joint Use and Maintenance Agreement for the shared private sewer line must be recorded prior to the issuance of building permits. The Joint Use and Maintenance Agreement must be reviewed and approved by Ms. Ilene Deckard of PCWWM Planning Services before it is signed and recorded. Ms. Deckard can be contacted at 740-6544 regarding this matter.

9. We will require a complete set of the revised bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.
Pima County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of a development plan or subdivision plat. The review fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.
The next submittal of this project will be the second (2nd) submittal. Please include a $50.00 check for the wastewater review fees (made out to PIMA COUNTY TREASURER) with the revised set of bluelines and response letter.

If other sheets are added to the set of plans, or revised in such a manner that the sewer design is impacted, please adjust the review fee accordingly.

If you wish to discuss the above comments, please contact me at 740-6563.




Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division

TR/tr
Copy: Project
02/19/2004 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S04-004 GLENN DUPLEXES/LOT SPLIT EXCEPTION
DATE: February 19, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Label suffixes for all street names on Location Map.

Delete address number and direction from street location (Glenn) and label suffix of street.
Add suffix of street to 3514 E. Glenn in Title Block.

Label unit number for each unit (1 thru 20).














jg
02/20/2004 JOE LINVILLE LANDSCAPE REVIEW Denied The project is subject to the provisions of LUC 3.7 and LUC 3.8. Submit landscape and native plant preservation plans.

Screening will be required along Glenn Street to screen the parking areas. The required screening may not be located within sight visibility triangles. LUC Table 3.7.2-I
02/20/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied COMPREHENSIVE PLANNING TASK FORCE COMMENTS

(1st review) Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S04-004 3514 E. Glenn 02/20/04

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
() Other – Lot Split Exception

CROSS REFERENCE: N/A

NEIGHBORHOOD PLAN: Grant-Alvernon Area Plan

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY: 2/23/04

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
( ) No Additional Comments

() No Resubmittal Required
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
() Other

REVIEWER: Joanne Hershenhorn 791-4505 DATE: 02/20/04


COMPREHENSIVE PLANNING TASK FORCE COMMENTS - S04-004 3514 E. Glenn


Illegal - Because by state law a subdivision is required for five or more splits and the LUC provisions allowing for lot split "exceptions" to the subdivision process mandate that the lots meet the requirements of a subdivision.

Criteria not followed - More than two lots are provided access from something other than an existing or proposed standard street cross section. There aren't even cross-access or use easements noted on the plans.

Criteria not followed - Parking is not provided on individual lots (including guest parking).

Criteria not followed - Garbage collection area is off of individual lots (located on one of the proposed lots).

Other problems - Required parking is provided on two of the lots to meet required parking for all of the proposed lots.

6. It is not clear whether the development meets the requirements of perimeter yard "BB" 10 or 3/4 H; without elevations it is not possible to determine. Given that the buildings are 20' tall, it is likely that a 15' perimeter yard will be required between each lot and on the perimeter of the "subdivision".

In general, the development should be designed either as a multifamily project on one site or as a standard R-2 subdivision. The subject property is within the boundaries of the Grant - Alvernon Area Plan (GAAP). The plan policies encourage increased home ownership opportunities in the area, this project is for rental units. In addition, GAAP policies support infill development that demonstrates sensitivity to the surrounding area through the use of design, location, orientation, landscaping, screening, etc. as outlined in the design guidelines. The submittal does not provide adequate information to determine compliance with those criteria.
02/20/2004 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: S04-004
Glenn Duplexes, Lots 1-5
Final Plat

TRANSMITTAL: February 19, 2004

DUE DATE: February 23, 2004

COMMENTS:

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before January 26, 2005.

2. This project does not qualify for the subdivision exception review and approval and will require a final plat review and approval due to a request by the DSD Engineering Review Section for assurances. The Zoning Review Section has reviewed this plan for compliance with criteria for the final plat format and content based on development standards 2-03.

Based on a cursory review, this plan does not meet the DS 2-03 final plat format and content criteria. Some or all of the following comments that pertain to the Zoning Review Section portion of the D.S. 2-03 final plat review have been taken directly from the Development Standards Manual. Please review the D.S. 2-03 final plat format and content and revise the plan as required.

3. Each sheet will measure 24" x 36" and include a two (2) inch margin on the left side and three-quarters (3/4) inch margins on the remaining sides to comply with standardization requirements of state law for recorded plats. Please keep in mind, when selecting the material on which the plat will be drawn, that a specific material is required for recordation by the Pima County Recorder's Office. Please refer to Sec. 2.03.8.1.A of this Standard. DS 2-03.6.1.B


4. A small, project-location map will be drawn in the upper right corner of the first sheet of the plat at a scale of 3" = 1 mile. The location map shall provide the following information.

a. Show the subject property approximately centered within a one (1) square mile area.

b. Identify conditions within the square mile area, such as subdivisions, major streets, major watercourses, and railroads. Reference recorded subdivision plats by book and page numbers.

c. Section, township, and range; section corners; north arrow; and the scale will be labeled.

d. The City's jurisdictional limits will be shown, if within the mapped area. DS 2-03.6.1.D

5. Place the words "Book ____ Page ____" in both the upper and lower right corners outside the margin line. The blanks will be completed by the Pima County Recorder's Office at the time of recordation. DS 2-03.6.1.G

6. A title block with the following information is to be provided in the lower right corner of each sheet.

a. Subdivision name; number of blocks, lots, and/or units; and common area.

b. Legal description by section, township, and range.

c. If the final plat is a re-subdivision of a previously recorded plat, indicate the title and the book and page reference of the existing subdivision. DS 2-03.6.1.H

7. The S(YR)-___ subdivision case number assigned to the approved tentative plat will be placed in the lower right corner of the plat next to the title block of all plan sheets. This project has been assigned the subdivision case number S04-004. List he case number as required. DS 2-03.6.1.K

8. A legend, which shows and describes all symbols used on the drawing, will be placed on either the first sheet of the plat or the first sheet, which contains all, or part of the subdivision drawing. DS 2-03.6.1.L

9. Add the following general note, "The gross area of this subdivision is ____ acres." DS 2-03.6.2.A

10. Add the following general note, "The total number of lots is 5." DS 2-03.6.2.B

11. Add the following general note, "There will be no further division of lots without the expressed approval of the City of Tucson." DS 2-03.6.2.H

12. Add the following general note, "(I/We), the undersigned, do hereby hold harmless the City of Tucson, its successors and assigns, their employees, officers, and agents from any and all claims for damages related to the use of the property depicted on this plat now and in the future by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall." DS 2-03.6.3.B.3

13. Add the Approval text block as indicated in DS 2-03.6.3.D. DS 2-03.6.3.D

14. Indicate if CC&R's are proposed for this project. If so please provide a copy of the document with the subsequent final plat submittal packet. DS 2-03.6.6.

15. The site plan drawings, which were submitted for review, are to be reference drawings for the proposed development and will be reviewed for Zoning and Development Standards compliance. The site plan drawings will not be recorded with the plat but will be kept and utilized as the development exhibit to the final plat for permitting purposes.

This project (site plan) has been reviewed as an apartment complex and must meet the same requirements. The requirements include vehicle and bicycle parking (number of spaces), parking space dimensions, PAAL widths, vehicular use areas such as wheel stops and back up spurs, pedestrian circulation, building setbacks, landscaping, NPPO, refuse container locations and types etc. Address the following items on the site plan.

16. Indicate on the plan if each of the existing structures on lot one (1) are constructed as duplexes. If so indicate that the existing structures are to be converted to 2 bedroom single family homes.

17. List on the plan that two (2) bicycle-parking spaces are required and that the two (2) class two spaces have been provided on lot 4.

18. Label the proposed building setbacks from all property lines. Based on the proposed 20-foot building heights for the new structures, the building setbacks from all interior property lines must be 15 feet. The new structures have been setback from the subdivision boundary 10 feet. The interior building setbacks have not been labeled and therefore compliance with the required building setback cannot be verified. Lot development options for the proposed building setbacks will be required.

19. The pedestrian circulation does not meet the continuous circulation requirement. Sidewalks have been provided to all units but the sidewalks do not connect. Provide crosswalks at key points that will connect the east and west sidewalks. Provide access ramps at the crosswalk locations. (The pedestrian circulation must be handicapped accessible.)

20. Add to the LUC Code Data text blocks the subject to section 3.5.7.1.F, which is applicable to all lots.

21. The text listing the floor area ratio and loading zones are criterion, which is not applicable to the proposed residential use and may be deleted from the text blocks.

22. See Landscape, Engineering and Fire Review Section comments. Additional comments may forthcoming based on subsequent final plat submittal packets.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\finalplat\S04004fp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat and CC&R's and additional requested documents
02/24/2004 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: February 24, 2004

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, Project S04-004 Glenn Duplexes: Other Subdivision Review

CC: Craig Gross, Development Services


Staff has reviewed and has no comments.

Please feel free to call me at 791-4873 x 215 if you have any questions.
02/25/2004 CRAIG GROSS OTHER AGENCIES PIMA ASSN OF GOVTS Passed
02/25/2004 DOROTHY ROBLES COT NON-DSD REAL ESTATE Denied Please have the applicant for 3514 E. Glenn (S04-004) provide Real Estate Division with a current title report and legal description for dedication of Glenn Street per MS&R and illustrate how legal access will be established and maintained to each development site after all the sites are sold to different parties.
02/25/2004 ED ABRIGO PIMA COUNTY ASSESSOR Denied Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR





TO: Oro Valley Planning Department (Fax-742-1022)
Attn: Shirley Gay
11000 N. La Canada Dr.
Tucson, Az 85737-7015


FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: February 24, 2004


RE: Assessor’s Review and Comments Regarding Final Plat
S04-004 Glenn Duplexes T131433 (111-08)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor’s Office requirements.
___X___ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Please make the following additions/corrections in your plat.
The title block must be in the lower right hand corner and must have the name of the subdivision, the number of lots, the common areas, if any; the map and plat of the old subdivision if it is a resub and the section, township and range.
The perimeter line must be solid and the heaviest line; the lot lines must be solid and the next heaviest in line weight.
Add the section tie
You must have general notes giving the gross square footage of the subdivision (or acres), the number of lots, the number of miles of new road, even if that number is 0, the basis of bearing and the basis of elevation.
If there are any questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.





Susan C. King
02/25/2004 DALE KELCH COT NON-DSD TRAFFIC Denied raffic Engineering REJECTS this plan.

1. Glenn Ave is classified as a collector roadway on the current MSRP. Table 5-2 of the Access management guidelines requires a 25' curb return vice a standard driveway apron for the access point to this project.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dkelch1@ci.tucson.az.us
02/25/2004 DALE KELCH COT NON-DSD TRAFFIC Denied raffic Engineering REJECTS this plan.

1. Glenn Ave is classified as a collector roadway on the current MSRP. Table 5-2 of the Access management guidelines requires a 25' curb return vice a standard driveway apron for the access point to this project.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dkelch1@ci.tucson.az.us
02/26/2004 PATRICIA GEHLEN ZONING RECORD LEGAL DESC Denied Zoning
2/26/2004
Legals may not be recorded until plan is approved