Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Plan Number - S04-003
Review Name: RESUBMITTAL - CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/16/2005 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 06/21/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-003 TRES PUEBLOS / REVISED FINAL PLAT DATE: JUNE 21, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. On Final Mylar 1: Label Placita Picacho El Diablo on pg. 12. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 06/27/2005 | DOUG WILLIAMS | ENGINEERING | REVIEW | Approved | TO: Craig Gross, CDRC SUBJECT: Tres Pueblos Lots 1-595 Final Plat Review DATE: 27 June 2005 CDRC #: S04-003 T15S, R14E, Sec. 8 Resubmittal: Revised Final Plat Mylar and a response letter addressing in detail how and where each item has been completed. Summary: The Final Plat may be recommended for conditional approval at this time. The items listed below must be fully addressed on the Final Plat Mylar. FINAL PLAT CONDITIONS OF APPROVAL: 1. Some of the knuckles show the correct radii dimensions, but are labeled incorrectly. Correct the remaining knuckle radii labels to 60' on all sheets, as indicated in previous comments, per Development Standard 3-01.10, Fig. 22. 2. Show all No Parking Areas on Sheets 4 -10 and 13, as similarly depicted on other sheets. 3. Clarify the length labeled (92.04') adjacent to Lot 491 (Sheet 5). Add crow's feet if necessary. 4. Depict and label the sewer line and sewer manhole easement as disclosed by deed recorded as Docket 7555, Page 786, described under item 5 of the title report. The easement information appearing in the title report as Docket 7098 Page 883 indicates the recording information provided on the Plat is inaccurate. Please check all easement recording information, revise recordation data on all sheets where inaccurate, and indicate any proposed abandonment's - fully labeled and dimensioned. 5. Indicate (depict and label) whether the easement described as a water pipe, sewer pipe or main and incidental purposes recorded in Docket 11387, Page 1316 continues on Sheets 12 and 13. If you have any questions, I can be reached at 791-5550, extension 1189 or via email at Doug.williams@tucson.az.gov Doug Williams Sr. Engineering Associate Engineering Division Development Services Department |
| 06/28/2005 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: TRES PUEBLOS Lots 1-595 S04-003 The Final Plat for the subject project will meet this Company's easement requirements. Please forward any resubmittals of the final plat to this office. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 07/05/2005 | MKALTHO1 | ZONING-DECISION LETTER | REVIEW | Completed |