Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW
Plan Number - S04-003
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/08/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/23/2004 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The Landscape Section recommends approval of the Tentative Plat subject to approval of the WASH Mitigation Plan. The Landscape Section recommends approval WASH Mitigation Plan subject to correction of the calculations as outlined in the 11/23/04 fax from TMHS. |
| 11/23/2004 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | TO: Craig Gross, CDRC SUBJECT: Tres Pueblos - Tentative Plat review REVIEWER: Doug Williams DATE: 23 November 2004 ACTIVITY NUMBER: S04-003 T15S, R14E, Section 8 Resubmittal Required: Revised Tentative Plat SUMMARY: Engineering Division has reviewed the Tentative Plat and drainage report addendum. The drainage report and addendum are approved for Tentative Plat purposes. Approval of the plat is not recommended at this time. Please address the following comments on a revised Tentative Plat and provide a response letter addressing the comments provided below: 1. Provide separate letter designations with specific corresponding descriptions for each Common Area (such as retention/detention area, drainageway/easement, open space etc). Each common area must be clearly differentiated from one another in the Title Blocks and on plan view labeling on all sheets (DS 2-03.2.4 C). 2. Review of the knuckle designs northeast of Lot 68 and adjacent to Lot 491 has revealed inconsistent information. Specifically, the radii should be 60' to the property line/right of way. Revise these radius dimensions to reflect 60' radii to the property line. Tentative and Final Plats should be consistent with one another (DS 3-01.10 Figures 5 & 22). 3. The Average Daily Traffic (ADT) exceeds 1000 vehicles per day on all streets within this subdivision. As such, street dimensioning and street cross-sections shall show compliance with Development Standard 3-01.10, Fig. 5. Resubmittal will require a revised Tentative Plat addressing the comments provided above. If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us. Douglas Williams Sr. Engineering Associate Engineering Division Development Services Department |
| 11/29/2004 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Completed | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 29, 2004 Colleen Stoetzel Rick Engineering 1745 E. River Road #101 Tucson, AZ 85718 Subject: S04-003 Tres Pueblos Tentative Plat Dear Colleen: Your submittal of November 5, 2004, for the above project has been reviewed by the Community Design Review Committee and the comments faxed to you reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have received and addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 3 Copies Revised Tentative Plat (engineering, landscaping, DSD) 3 Copies Revised Landscaping Plan (engineering, landscaping, DSD) 2 Copies Revised Drainage Report (engineering, DSD) 2 Copies Soils Report (engineering, DSD) 3 Copies Revised WASH Report (engineering, landscaping, DSD) Should you have any questions, please call me at 791-5608. Sincerely, Craig L. Gross CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |