Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - FINAL PLAT REVIEW
Plan Number - S04-003
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/05/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/08/2004 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | November 8, 2004 TO: James King Rick Engineering Company THRU: Craig Gross City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Tres Pueblos, Lots 1-595 and Common Areas A1-A3, B1-B7 and C1-C7 Final Plat – 2nd Submittal S04-003 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The June 8, 2004 review letter erroneously stated that a sewer service agreement had been sent to your office, therefore A public Sewer Service Agreement for the proposed number of residential lots is being e-mailed to you at this time. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat. SHEET 2. Public sewer easements across common areas are no longer required as these common areas will be dedicated in the final plat. Therefore, the public sewer easement on this sheet is not required. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 11/09/2004 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: TRES PUEBLOS Lots 1-595 S04-003 Tucson Electric Power Company (TEP) has reviewed the final plat dated October 21, 2004. TEP is unable to approve the plat at this time. In order for this Company to approve the final plat, the following easements are required: * A 15' x 15' easement is required at each of the PME (pad mounted equipment) locations, there is one south of Lot 13 and east of Lot 403. * A 10' wide easement is required for the duct that is being installed to each PME. As shown on the preliminary design. * A 10' x 10' easement is required for the junction cabinet located east of Lot 310. Show all requested easements on the resubmittal of the final plat. Submit two bluelines to the City of Tucson for TEP's final approval. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo Land Management Tucson Electric Power Company lcastillo@tep.com Office: (520) 917-8745 Cell Phone: (520) 904-2668 Fax: (520) 917-8700 |
| 11/17/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S04-003 TRES PUEBLOS/REVISED FINAL PLAT DATE: NOVEMBER 16, 2004 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Label Street Names on Sheet Index. Correct Avenida Barranca Seco to Avenida Barranca Seca (sheets 1, 7, & 10). Correct Avenida Selva De Ocote to Avenida Selva Del Ocote (sheets 1, 6 & 9). Correct Avenida Lena to Calle Lena Verde (sheets 1, 9, 10 & 13). jg |
| 11/23/2004 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES November 29, 2004 Colleen Stoetzel Rick Engineering 1745 E. River Road #101 Tucson, AZ 85718 Subject: S04-003 Tres Pueblos Final Plat Dear Colleen: Your submittal of November 4, 2004, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Plat (addressing, engineering, wastewater, TEP, DSD) 2 Copies Boundary Closure Calculations (engineering, DSD) 2 Copies CC&R's (engineering, DSD) REVISED ASSURANCES TO BE SUBMITTED TO THE CDRC OFFICE Should you have any questions, please call me at 791-5608. Sincerely, Craig L. Gross CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |
| 11/23/2004 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | TO: Craig Gross, CDRC SUBJECT: Tres Pueblos - Final Plat review REVIEWER: Doug Williams DATE: 23 November 2004 ACTIVITY NUMBER: S04-003 T15S, R14E, Section 8 Resubmittals Required: Revised Final Plat and a complete revised Subdivision Assurance Package. SUMMARY: Engineering Division has reviewed the Final Plat, Assurances Package and Covenants Conditions and Restrictions (CC&R's). Approvals are not recommended at this time. Please address the following comments and provide a response letter addressing each item in a resubmittal: FINAL PLAT: 1. Provide separate letter designations with specific corresponding descriptions for each Common Area (such as retention/detention area, drainageway/easement, open space etc). Each common area must be clearly differentiated from one another in the Title Blocks and on plan view labeling on all sheets (DS 2-03.6.4 C). 2. Review of the knuckle designs northeast of Lot 68 and adjacent to Lot 491 has revealed inconsistent information. Specifically, the radii should be 60' to the property line/right of way. Revise these radius dimensions to reflect 60' radii to the property line. The Tentative Plat should reflect these changes to assure the Tentative and Final Plats are consistent with one another (DS 3-01.10 Figures 5 & 22). 3. The Average Daily Traffic (ADT) exceeds 1000 vehicles per day on all streets within this subdivision. As such, street dimensioning and street cross-sections shall show compliance with Development Standard 3-01.10, Fig. 5. ASSURANCES: 4. Provide a copy of the original Trust agreement (DS 2-03.6.3 B & C). 5. Revise the description of "The Property" in the "Recitals" paragraph (A) of the Agreement to Construct Subdivision Improvements Third Party Trust, in paragraph 1 of the Amendment to Trust, and in the legal description of the property (Exhibit A - each document), to read exactly as it reads in the Title Block of the plat. Descriptions for common areas must also specify their purpose/use (street, detention/retention basin, etc.). Assure all revisions to the Plat Title Block match these documents exactly (see plat comment # 1-previous comment # 8). 6. Please indicate the Exhibit letter designation (A), as referenced in paragraph 1 at the heading of the legal description in the "Amendment to Trust" document. Include the CDRC case number (S04-003), and revise the common area descriptions to show consistency with the Plat title blocks, CC&R's, and the Agreement to Construct Subdivision Improvements Recitals paragraph. 7. Revise the common area descriptions in Exhibits A and B in the Agreement to Construct Subdivision Improvements document. Please include the CDRC case # (S04-003) on each exhibit. CC&R's: 8. Please revise the Common Area descriptions to match exactly as provided on all other documents, on the cover sheet and in Exhibit A (page 51). 9. Omit the question (in bold/brackets) in section 3.1.2 (page 8). 10. Section 4.7 (page 20) of the CC&R's describes a 10' Landscape/Pedestrian Easement measured from back of curb, yet keynote 1 on the plat identifies a 10' public utility easement. Revise as necessary for consistency, to include revising keynote 1 on the plat, if necessary. 11. Exhibit A should be revised to reflect any changes that occur to the legal description, in response to Assurances comment # 2, below. Resubmittal will require a revised Final Plat and a complete, revised subdivision assurance package addressing all of the comments provided above. The Plat may not be recommended for approval prior to Engineering approval of subdivision assurances. If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us. Douglas Williams Sr. Engineering Associate Engineering Division Development Services Department |