Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Plan Number - S03-038
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/26/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/28/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 08/02/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 08/09/2005 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | August 1, 2005 TO: John Wood, P.E. Presidio Engineering, Inc. THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: La Cholla Landing, Lots 1-61 and Common Areas A-C Tentative Plat – 3rd Submittal S03-038 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. This project is hereby approved as submitted. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 08/09/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | URBAN PLANNING AND DESIGN COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S03-038 La Cholla Landing 08/04/05 (XXXX) Tentative Plat () Development Plan (XXXX) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: NEIGHBORHOOD PLAN: Santa Cruz Area Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 8/09/05 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies (XXXX) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (XXX) Resubmittal Required: (XXXX) Tentative Plat () Development Plan (XXXX) Landscape Plan () Other REVIEWER: DCE 791-4505 DATE: 04/21/05 URBAN PLANNING AND DESIGN S03-038 La Cholla Landing Please add the following comment to the “General Notes” section of the tentative plat: “Safe by Design” concepts will be applied along the back of lots 16 through 19 and along the south side of lot 16. Active/passive recreation areas shall be handicap accessible by an all-weather path, no less than five feet in width. On the landscape plan, please show a detail of the handicapped accessible pedestrian path showing the width and what type of materials will be used in the recreation area, Common Area B. |
| 08/17/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Patricia Gehlen; CDRC Coordinator SUBJECT: La Cholla Landing 3rd submittal Tentative Plat Engineering Review LOCATION: T13S R13E Section 27 REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: S03-038 SUMMARY: The revised Tentative Plat (dated 7/13/05), Western Tech geotechnical report, copy of FEMA CLOMR letter, revised Drainage Report (dated 27JUNE2005), Landscape documents, and response letter were received by Engineering on July 26, 2005. Engineering has reviewed the received items and does not recommend approval of the Tentative Plat or the Drainage Report at this time. The Drainage Report was reviewed for Tentative Plat purposes only. DRAINAGE REPORT COMMENTS: 1) City of Tucson Development Standards (DS) Section No.10-02.2.3.1.4.G: Regarding the Santa Cruz River Zone AE FEMA floodplain partially on this project, please revise the Drainage Report page to reflect the update on CLOMR review status. Also add to the drainage addendum/response letter to the drainage report. 2) DS Sec.2-03.2.4.L.2: Address the following drainage comments in the report: a) On page 16 of the Drainage Report, it still states that several lots will be below the basin WSEL and a flood restraint wall is proposed, whereas the response letter stated this would be deleted/revised. Update Drainage Report. b) DS Sec.2-03.2.4.L.4: Provide information to clarify depth of foundations; describe difference between FPE and FFE. Also, clarify the PAD elevations on planview sheet 2 so that the FFE's for lots 1-15 are above the Basin 2 WSEL. c) Exit spillways shall be further detailed for future grading plan submittal, to accommodate for dimensions, any rock sizing etc. 3) DS Sec.10-02.14.2.6: Applicant shall acknowledge in drainage report or response letter that additional percolation tests may be required during the post grading construction phase of the project in order to show that as-built basins meet percolation requirements. TENTATIVE PLAT COMMENTS 4) DS Sec.2-03.2.4.L.4&6: Clarify that the minimum lowest floor elevations per drainage report shall be achieved for specific lots as listed in General Note 29 or by a legend symbol or other notation. This helps review of future plot plans. 5) DS Sec.2-03.2.4.K: Check the following: a) Assure basin access ramp widths are called out as 15-ft wide on planview. Also, on sheet 4, revise keynote 12 to reflect 15-ft (not 12-ft) wide basin access ramp. b) Label weir elevations for both basins on Tentative Plat, see detail 7/5. 6) DS Sec.2-03.2.4.F: Provide concrete header on both sides of street for detail 9/4. 7) DS Sec.2-03.2.3.E&H: Provide status of well closures/abandonments in proposed locations of basin 1 and lot 18. 8) DS Sec.2-03.2.1.J: Regarding the legend and plan view, darken or provide more legible copy so that the hatching for the lime treatment symbol is legible. 9) DS Sec.2-03.2.1.C: All lettering and dimensions will be the equivalent of twelve (0.12) point or greater in size. The purpose of this requirement is to assure that the lettering is legible when reproduced or when photographically reduced (microfilmed) for recordkeeping purposes. Specifically, the common area text in the title block needs to be 12 pt. 10) DS Sec.10-02.14.2.6: For Grading Plan review, provide two copies of the compiled bound copy of the Geotechnical Report with the geotechnical addenda included. LANDSCAPE PLAN COMMENTS 11) DS Sec.10-02.14.3.4: For Basin 1 access, assure that no proposed vegetation will block access. It appears there are trees proposed in the access area which is the north channel for this basin. The next submittal should address all the above items. Submit the revised Tentative Plat, revised Drainage Report, revised Landscape plans, and a complete bound copy of soils report with all addenda or revisions. You may call to schedule an appointment to go over these comments, or if you have any questions, please call me at 791-5550 extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 08/19/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 19, 2005 John Wood Presidio Engineering 2302 East Speedway Blvd., #214 Tucson, AZ 85709 Subject: S03-038 La Cholla Landing Tentative Plat Dear John: Your submittal of July 26, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have received and addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 4 Copies Revised Tentative Plat (Zoning, Engineering, Community Planning, DSD) 4 Copies Revised Landscaping Plan (Zoning, Engineering, Community Planning, DSD) 2 Copies Revised Drainage Report (Engineering, DSD) 2 Copies Revised Soils Report ( Engineering, DSD) Should you have any questions, please call me at 791-5608. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 795-6747 |