Plan Number: S03-033
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S03-033
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2004 MARILYN KALTHOFF START PLANS SUBMITTED Completed
05/19/2004 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-033 SILVERBELL VISTA/FINAL PLAT
DATE: May 19, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
05/25/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: SILVERBELL VISTA
Lots 1-40
S03-033

Tucson Electric Power Company (TEP) has received the final plat for review dated May 14, 2004. This Company is unable to approve the plat at this time.

An electrical design to determine our easement requirements will be provided on the Approved Tentative Plat with fifteen (15) working days upon receipt of the plat. At the customer's request, a design can be provided prior to the Approved Tentative Plat, however, once a design is provided, any design changes may be billable to the developer.

Please contact me at (520) 917-8479 if you have any questions.

Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Cell Phone/Pager: (520) 904-2668
Fax: (520) 917-8400
06/08/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: June 7, 2004


RE: Assessor’s Review and Comments Regarding Final Plat
S03-033 Silverbell Vista T131333 (103-21)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.





Susan C. King
06/14/2004 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Peter McLaughlin
Senior Planner
FOR: Patricia Gehlen
Principal Planner

PROJECT:
Silverbell Vista
S03-033
Final Plat

TRANSMITTAL: June 14, 2004
DUE DATE: June 14, 2004

1. Reference recorded subdivision plats by book and page numbers in the location map.
DS 2-03.6.1.D.2

2. The tentative plat must be approved prior to final plat approval. LUC 4.1.7.3

3. Revise Dedications Block to be consistent with DS 2-03.6.3.B, including a printed name and a signature line. DS 2-03.6.3.B

4. If applicable, provide a Beneficiary Block. DS 2-03.6.3.C


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
06/15/2004 FRODRIG2 PIMA COUNTY WASTEWATER Denied June 14, 2004

TO: Morris I. Riback, P.E., Urban Engineering, Inc.

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Silverbell Vista, Lots 1-40 and Common Areas A-C
- Submittal
S03-033


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEET 1. Revise the third paragraph of the Dedication to read

PRIVATE STREETS, DRAINAGEWAYS AND COMMON AREAS AS SHOWN HEREON ARE RESERVED FOR THE PRIVATE USE AND CONVENIENCE OF ALL OWNERS OF PROPERTY WITHIN THIS SUBDIVISION AND ARE GRANTED AS EASEMENTS TO THE PUBLIC AND ALL UTILITY COMPANIES FOR THE INSTALLATION AND MAINTENANCE OF ABOVEGROUND AND UNDERGROUND UTILITIES AND PUBLIC SEWERS.

TITLE TO THE LAND ALL COMMON AREAS SHALL BE IN VESTED IN AN ASSOCIATION OF INDIVIDUAL LOT OWNERS AS ESTBLISHED BY COVENANTS, CONDITIONS AND RESTRICTIONS RECORDED IN DOCKET _______ AT PAGES ________, IN THE OFFICE OF THE PIMA COUNTY RECORDER. THIS ASSOCIATION WILL ACCEPT RESPONSIBILITY FOR CONTROL, MAINTENANCE AND LIABILITY FOR THE PRIVATE STREETS, DRAINAGEWAYS, PRIVATE SEWERS AND COMMON AREAS WITHIN THE SUBDIVISION.

We will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.


County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.
06/16/2004 DOUG WILLIAMS ENGINEERING REVIEW Denied TO: Craig Gross, CDRC
SUBJECT: Silverbell Vista - Final Plat review
REVIEWER: Doug Williams
DATE: 15 June 2004
ACTIVITY NUMBER: S03-033
T13S, R13E, Section 33

Resubmittals Required: Revised Final Plat, 2 complete subdivision assurance packages, and boundary survey closure calculations.

SUMMARY: Engineering Division has reviewed the Final Plat and CC&R's. Approval is not recommended at this time. The following comments must be addressed prior to resubmittal:

1. Please omit the maintenance access easement depicted at the northeast corner of the site, per previous discussions.
2. 100-year Floodplain limits that are entirely contained within a street section or constructed drainageway shall be labeled as such on the plat, or a general note shall be included on the plat, which states the same (DS 10-02.5.2.3
3. Provide a note stating that the owner/developer agrees to (1) have an Arizona Registered Professional Land Surveyor certify the finished floor elevations of all new structures located within the floodplain; and (2) obtain a floodplain use permit from the City Engineer (DS 10-02.5.2.6).
4. Include in the CC&R's, or add a note to the plat stating: (a) that the owner(s) shall be solely responsible for, operation, maintenance and liability for the drainage basin(s); (b) That the owner(s) shall have an Arizona Registered professional Civil Engineer prepare a certified inspection report for the drainage and detention/retention facilities at least once a year, and that these regular inspection reports will be on file with the owner for review by city staff, upon written request; (c) that city staff may periodically inspect the drainage and detention/retention facilities to verify scheduled and unscheduled maintenance activities are being performed adequately; and (d) that the owners(s) agree to reimburse the city for any and all costs associated with maintaining the drainage and detention/retention facilities, should the city find the owner(s) deficient in their obligation to adequately operate and maintain their facilities (DS 10-02.14.3.2).
5. Revise the Certification of Survey paragraph to reflect the language specified for "…all existing and proposed survey monuments and markers shown are correctly described. I further certify that this plat was prepared under my direction"(DS 3-02.6.3 A).
6. Revise the Dedication paragraph to reflect dedications to the Public or the City of Tucson - not Pima County; and revise or omit the dedication of easements in this paragraph (DS 2-03.6.3 B 2 a).
7. If applicable, include a Beneficiary block on the Title page (DS 2-03.6.3 C).
8. Please replace the signature block title of "City of Tucson Engineer" to "City of Tucson Development Services Department Engineering Division Administrator".
9. Provide separate letter designations with specific descriptions of each Common Area (retention/detention areas and drainageways/easements must be differentiated from one another), in the Title Block on sheet 1 and in the Title Block and on plan view labeling on sheet 2.
10. Show the limits of 100-year floodprone areas in a surveyable and readily retraceable manner with frequent ties to intersecting lot lines for all flows of 100-cfs or more (DS 2-03.6.4 F).
11. Show detention/retention basin 100-year ponding limits in a surveyable and readily retraceable manner (DS 2-03.6.4 F).
12. Provide boundary survey closure calculations (DS 2-03.6.5).
13. Omit or provide a clear description with tie-down information for the additional (radial?) ¼ corner tie-in depicted east of Silverbell Road (DS 2-03.6.5 A).
14. Ensure all tract boundary lines; easements, and other rights-of-way; and property lines of residential units, and common areas, with accurate dimensions, bearings, or deflection angles and radii, arcs and central angles of all curves are indicated and labeled properly (DS Sec.2-03.6.5.B&C).
15. Note that a ½" iron rod will be set at all corners upon completion of construction (DS 2-03.6.5 C 4 b).
16. Provide additional monuments to be set along the street monument line at all points of curvature and points of reverse curves (south and west of Lot 35) (DS 2-03.6.5 C 6).
17. City of Tucson Development Standards (DS) 1-04.1 requires all subdivision improvements be completed prior to transmittal of a Final Plat to Mayor and Council for consideration. Alternatives include posting of a Performance Bond, establishing a Cash Escrow Account, providing a Letter of Credit or providing Subdivision Assurances. Please address this requirement prior to, or concurrent with a Final Plat resubmittal.
18. Include a current title report with a subdivision assurance package submittal (DS 1-04.2 and 2-03.7.1).
19. Provide written documentation/verification from Tucson Department of Transportation (TDOT) demonstrating compliance with, or consent to construct or contribute funding toward all required improvements stipulated as conditions of rezoning for this project. These include the items listed in rezoning condition numbers 10, 11, 16 (a-c), 17 & 18. The Final Plat may not be recommended for Mayor and Council consideration prior to demonstration of conformance to these conditions.

GENERAL COMMENT:

The consultant may wish to insert a period between the words "sewers" and "title" and between the words "Recorder" and "The Association" in the third paragraph under "Dedication" (DS 2-03.6.3 B 2 c).

Resubmittal will require a revised Final Plat, boundary survey closure calculations and 2 subdivision assurance packages, addressing all of the comments provided above. The Plat may not be recommended for approval prior to Engineering approval of subdivision assurances.
If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Douglas Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
06/17/2004 CRAIG GROSS COT NON-DSD REAL ESTATE Approved no comments.