Plan Number: S03-033
Parcel: Unknown

Review Status: Completed

Review Details: REVISION - TENTATIVE PLAT REVIEW

Plan Number - S03-033
Review Name: REVISION - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/13/2006 PETER MCLAUGHLIN ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
Silverbell Vista RCP
S03-033
Tentative Plat
Revision to number of lots

TRANSMITTAL: February 12, 2006
DUE DATE: February 23, 2006


The Zoning Review Section at Development Services verifies that the tentative plat meets the requirements of the Land Use Code, subject to the following requirement. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.


1. The revision to this tentative plat will not result in a new subdivision case number being assigned. The original case number (S03-033) will still apply. Therefore, remove the note that reads "OLD" next to the development plan case number and remove the spaces for a new case number on from . Instead, a note stating "Revised" may be placed next to the original subdivision case number on each sheet.

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
02/21/2006 JIM EGAN COT NON-DSD FIRE Approved
02/23/2006 JOE LINVILLE LANDSCAPE REVIEW Approved
02/27/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-033 SILVERBELL VISTA REVISION / REVISED TENTATIVE PLAT
DATE: February 22, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Is the entire subdivision going to be resubdivided or only the portion that is changing?
If only the portion that is changing than please correct Location Map and add all
resubdivision information to all Title Blocks.
02/27/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied COMPREHENSIVE PLANNING TASK FORCE COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S03-033 Silverbell Vista 02/23/06

(x) Tentative Plat
() Development Plan
(x) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-03-11

NEIGHBORHOOD PLAN: Tucson Mountain Subregional Plan

GATEWAY/SCENIC ROUTE: Scenic Route

COMMENTS DUE BY: 02/23/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(x) Resubmittal Required:
(x) Tentative Plat
() Development Plan
() Landscape Plan
(x) Other: building elevations for units 36, 37, 38&39

REVIEWER: D. Estolano 791-4505 DATE: 02/17/06
Urban Planning and Design Comments
Silverbell Vista, S03-33

Rezoning Condition 9 states that an appropriate mix of building facades and roof lines are required. The condition also states that building facades and rooflines of units visible from Silverbell Road and those located on lots 36, 37, 38, 39, and 40 must be reviewed in this context to verify compliance with this condition.

Resubmittal of the previously approved Tentative Plat has revised the plat from 40 lots to 39 lots. The five lots, 36, 37, 38, and 40 at the southwest corner of the subdivision have been enlarged and are now identified as lots 36, 37, 38, and 39. Please submit elevations of the appropriate details of the proposed building facades and rooflines of the above-mentioned lots and add a note to the tentative plat stating these units will be limited to one-story.
02/27/2006 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor


115 N. Church Ave.


Tucson, Arizona 85701



BILL STAPLES

ASSESSOR










TO: CDRC Office

Subdivision Review

City of Tucson (FAX# 791-5559)



FROM: Gary Ault, Mapping Supervisor

Pima County Assessor's Office

Mapping Department



DATE: February 21, 2006





RE: Assessor's Review and Comments Regarding Tentative Plat

S03-033 Silverbell Vista T131333 (103-21)




* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *



X Plat meets Assessor's Office requirements.

_______ Plat does not meet Assessor's Office requirements.





COMMENTS: IN ORDER FOR THIS PLAT TO MEET THE ASSESSOR'S STANDARDS, PLEASE
MAKE THE FOLLOWING ADJUSTMENTS:



1. ADD BEARINGS FOR ALL LINES

2. ADD COMPLETE CURVE DATA

THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA
WERNER AT 740-4390





NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO
DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE
COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS
OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY
DIGITAL DATA PREVIOUSLY SUBMITTED.









GA/rw
03/01/2006 LOREN MAKUS ENGINEERING REVIEW Approved The Engineering Division has reviewed the revised tentative plat and recommends approval.
Loren Makus, E.I.T.
Senior Engineering Associate
03/01/2006 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this revised TP.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
03/01/2006 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: SILVERBELL VISTA: REVISION

S03-033



Tucson Electric Power Company (TEP) has no objection to the tentative
submitted for review dated February 8, 2006.



The electrical facilities for these lots have been installed. Once the
final plat is approved and recorded please forward to my attention the
AutoCAD version of the plat for accurate updating of TEP's Landbase.


Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com
03/03/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied March 2, 2006

TO: Charles Corrales
Steve Corrales Engineering Corporation

THRU: Patricia Gehlen
City of Tucson Development Services Department

FROM: R S Engineering (Contract Reviewer)
Subhash Raval, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Silverbell Vista
Tentative Plat – 3rd Submittal
S03-033


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEET 1. General Note 14 states “public” sewer line, composite map labels sewer as “private”. Please make the appropriate corrections.

SHEET 1. There are two manholes labeled 10. Change last manhole to 11.

SHEET 1. Show 6-digit Pima County manhole number for existing public manhole 3.

SHEET 1. Label the size of the existing public sewer line.

SHEET 4. Verify all sewer lengths, inverts, and pipe slopes. Numerous slopes and lengths appear to be incorrect. Show pipe slopes to at least 2 decimal places.

SHEET 5. Show 6-digit Pima County manhole number for existing public manhole 3. Label the existing sanitary sewer easement and show docket and page number.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 4th submittal. A check for the review fee of this submittal in the amount of $117.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Subhash Raval, P.E.
Telephone: (520) 740-6586

Copy: Project
03/16/2006 FRODRIG2 ENV SVCS REVIEW Approved All lots have curb side frontage and approved for APC curb side service per John Clark.
03/20/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 20, 2006

Steve Corrales Engineering Corporation
1008 West St. Mary's Road
Tucson, Arizona 85745

Subject: S03-033 - Silverbell Vista Revised Tentative plat

To Whom It May Concern:

Your submittal of February 8, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Tentative Plat (Community Planning, Addressing, Wastewater, DSD)

2 Copies Building Elevations (Community Planning, DSD)




Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 622-2554