Plan Number: S03-032
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S03-032
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/08/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/09/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: CENTENNIAL TERRACES
Lots 1-17
S03-032

The Final Plat for the subject project will meet this Company's easement requirements.
Please forward any resubmittals of the final plat to this office.

Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission.




Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Cell Phone/Pager: (520) 904-2668
Fax: (520) 917-8400
07/09/2004 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-032 CENTENNIAL TERRACES/FINAL PLAT
DATE: July 9, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:



Include Section numbers on Location Plan.

Label Rayburn Place on pg. 2.














jg
07/22/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: July 21, 2004


RE: Assessor’s Review and Comments Regarding Final Plat
S03-032 Centennial Terraces T141510 (133-30)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
____ __ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Per phone conference with Mr. Tsang,
The following items will be added before recording.
The bearing will be added to the north line of lots 9 and 10.
The dimension will be added to the north line of Common Area “C”.
If there are any questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan King
08/02/2004 LOREN MAKUS ENGINEERING REVIEW Approv-Cond DATE: August 2, 2004
TO: Craig Gross; CDRC Coordinator
SUBJECT: Centennial Terraces Final Plat Engineering Review
REVIEWER: Loren Makus
ACTIVITY NUMBER: S03-032


SUMMARY: The Final Plat has been reviewed by Development Services Department Engineering Division. We conditionally recommend approval of the Final Plat at this time. A complete, corrected assurances package must be submitted with the Mylars.

The complete assurances package must include a copy of the original trust, the original amendment to trust with exhibit A, the original agreement to construct with exhibit B, a copy of the warranty deed, a current title report and a location map on an 8 ½ x 11 sheet.
Revise the Amendment to Trust and the Agreement to Construct to match the Final Plat title block. Spell out the word "Natural."
Remove the name of the proposed private street from the list of assurable items.

Include a copy of the Covenants, Conditons and Restriction for the subdivision. Include language requiring maintenance of the drainage facilities by the Homeowners Association.

If you have any questions call me at 791-5550, extension 1161 or email me at loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
Engineering Division
Development Services
08/02/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Denied August 02, 2004

TO: Anthony C. Tsang, A. C. Tsang Engineering Group, Inc.

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Centennial Terraces, Lots 1-17 and Common Areas A-C
- Submittal
S03-032


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEETS 1and 2. The common areas between Lots 6 &7 and Lots 11 & 12 are labeled Common Area A. This is not an appropriate label for these common areas, as Common Area A has been defined in the title block as PRIVATE STREETS. We recommend these common areas be labeled as Common Area B, and the definition of Common Area B, be changed to UTILITIES AND DRAINAGE.

SHEET 1. Add a General Note that states:

THE LANDSCAPING WITHIN COMMON AREA ___ BETWEEN LOTS 6 AND 7 SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4.

with the blank filled in appropriately.

3. SHEET 1. Add a General Note that states:

NO PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) MAY BE CONSTRUCTED ON OR THROUGH COMMON AREA ___A BETWEEN LOTS 6 AND 7 WITHOUT SEPARATE WRITTEN CONSENT OF PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

With the blank filled in appropriately.

SHEET 1. Show the trust number on the final plat, and fax the trust number, and the full name and address of the trust company to me at 740-6380. After this information has been faxed to me, a Sewer Service Agreement will be prepared and sent to your office for signature under separate cover.

We will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.

DF/TR/tr

Copy: Project
08/05/2004 DAN CASTRO ZONING REVIEW Denied COMMENTS
CODE SECTION/ DEVELOPMENT STANDARD

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before April 14, 2005.

2. Since this subdivision is a Residential Cluster Project (RCP), a statement to that effect shall be included in the title block.
D.S. 2-03.2.1.G/ D.S. 2-03.6.1.H

3. Provide the following note: "This plat is subject to Board of Adjustment variance C10-04-03, unless expired or superceded by a subsequent application."
D.S. 2-03.6.2.G

4. The CC&R's must be revised as follows: On the cover sheet please reference all the subdivision information found in the title block located on each sheet of the final plat (i.e. subdivision name, number of lots, RCP statement, and all common areas). Common area "C" is not listed.
D.S. 2-03.6.6

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
08/09/2004 DOROTHY ROBLES COT NON-DSD REAL ESTATE Approved no objection.
08/09/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed