Plan Number: S03-024
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S03-024
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/06/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/07/2004 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-024 PANTANO’S EDGE / FINAL PLAT
DATE: April 7, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Correct Pantano Edge Street to Pantano Edge Drive or Way (the direction of this road
has not been determined yet. “Street” can only be used for east/west roads). Please
make correction on all sheets, including Index Map.
04/07/2004 KAY MARKS PIMA COUNTY ADDRESSING Approv-Cond Conditionally Approved : to be checked on final Mylar.

1. Change Sarnoff Road to Sarnoff Drive on Location Map

2. Change Fon Du Lac Drive to Fond Du Lac Drive on all applicable pages.
04/23/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: PANTANO'S EDGE
Lots 1-71
S03-024

The Final Plat for the subject project will meet this Company's easement requirements.
Please forward any resubmittals of the final plat to this office.

Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission.



Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Pager: (520) 218-6565
Fax: (520) 917-8400
04/23/2004 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: Douglas Schneider, P.R.L.S. DATE: April 23, 2004
Rick Engineering Co.
1745 E. River Road
Tucson, Arizona 85718

SUBJECT: Pantano's Edge,
Final Plat S03-0019 (First Review)
T13S, R15E, Section 32

RESUBMITTAL REQUIRED: Final plat.

The Final plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Final Plat:

1. Please include a response letter to the comments along with the corrected copies with re-submittal.
2. The "Legend" lists a "FEMA flood prone limit", where is this shown on the plans?
3. Please label the access points with a "star" on lots 52, 53 and 69 per D.S. 2-03.6.4.G.
4. Please remove the setback lines on lots 1, 2 and 3. The setbacks may called out as a note on the cover sheet.
5. Please add to general notes 6.2.I per D.S. 2-03.0.
6. Please edit the paragraph five of the Dedications to read verbatim per D.S. 2-03.0.C or D.
7. Please show erosion hazard setbacks and the 100-year floodplain in a surveyable manner per D.S. 2-03.6.4.E and F.
8. Please add a 1' access control easement along the Northeast sides of lots 50, 55-56, 61-62, 66-67, 70 and 71 per D.S. 2-03.6.4.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
04/23/2004 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: Colleen Stoetzel DATE: June 4, 2004
Rick Engineering Co.
1745 E. River Road
Tucson, Arizona 85718


SUBJECT: Pantano's Edge,
Final Plat S03-0019 (Second Review)
T13S, R15E, Section 32

RESUBMITTAL REQUIRED: None.

Final Plat:

1. 1. A conditional approval on the final plat is granted upon the receipt of approved bank protection plans from P.C.F.C.D. and that horizontal distance for the "key in" for the bank protection is (adequate for the design) acceptable to P.C.F.C.D.


If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
04/29/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approved 1. SHHET 1. Add a General Note that reads

"ALL LANDSCAPING WITHIN THE PUBLIC SEWER EASEMENT ACROSS COMMON AREA A-1 SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4."

2. SHEET 2. The Pima County Wastewater Management Department has recently begun asking for specific public sewer easements where public sewer lines cross common areas that may be landscaped with trees and other vegetation that may cause root intrusion problems. Show a 25-foot public sewer easement by final plat where the public sewer line will cross Common Area A-1, between lots 1 and 71.

3. Under separate cover, a public Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals should be
returned to Pima County Wastewater Management in order to satisfy the necessary requirements needed to approve the Mylars of the final plat.

4. We will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of the final plat. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

The next submittal of this project will be the second (2nd) submittal. A check for the review fee of this submittal in the amount of $50.00 (made out to PIMA COUNTY TREASURER ) must accompany the revised set of bluelines and response letter.

If the number of sheets changes, please adjust the review fee accordingly.

If you wish to discuss the above comments, please contact me at the phone number provided on the first sheet.

Copy: Project
04/29/2004 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approved May 26, 2004

TO: Colleen Stoetzel, Rick Engineering Company

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Pantano's Edge, Lots 1-71 and Common Areas A1-A3 and B1-B3
- Submittal
S03-024


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use:


A revised set of bluelines showing the necessary corrections and three signed and notarized Sewer Service Agreements for this project have been received by this office. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat.

As previously verbally agreed, Item 4 of our April 28, 2004 review letter (regarding wastewater review fees) is hereby retracted. No additional wastewater review fees must be paid for this final plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.
05/04/2004 DAN CASTRO ZONING REVIEW Approved
05/04/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: May 3, 2004


RE: Assessor’s Review and Comments Regarding Final Plat
S03-024 Pantano’s Edge T141528 (136-14)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Before recording this plat, please put the basis of bearing on the dedication page. I know it is on sheet two, but it also needs to be on sheet 1. If there are any questions, please contact Susan King 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan C. King
05/05/2004 DOROTHY ROBLES COT NON-DSD REAL ESTATE Approved no comments.