Plan Number: S03-016
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT REVIEW

Plan Number - S03-016
Review Name: FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/30/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/04/2004 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-016 BARRIO ESCALANTE SUBDIVISION/FINAL PLAT
DATE: May 3, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***












jg
05/07/2004 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: BARRIO ESCALANTE
Lots 1-46
S03-016

Tucson Electric Power Company (TEP) has reviewed the final plat dated April 28, 2004. TEP is unable to approve the plat at this time.

In order for this Company to approve the final plat, the following will be required.

A 6' x 6' easement is required at the pedestal location between Lot 1 and 2.
A 10' x 10' easement is required at the junction cabinet location east of Lot 24 within Common Area "C". In order to verify that there is not a conflict with the drainage basin and the junction cabinet please sends in a detailed sketch of this area.
Add the following to the dedication: WE HEREBY GRANT TO THE CITY OF TUCSON, PIMA COUNTY, AND ALL UTILITY COMPANIES ALL PUBLIC EASEMENTS AS SHOWN HEREON FOR THE PURPOSE OF ACCESS, INSTALLATION AND MAINTENANCE OF PUBLIC SEWERS AND UTILITIES AND OTHER USES AS DESIGNATED BY THIS PLAT.

Show all requested easements on the resubmittal of the final plat. Submit two bluelines to the City of Tucson for TEP's final approval. Please contact me at (520) 917-8479 if you have any questions.



Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Pager: (520) 218-6565
Fax: (520) 917-8400
05/17/2004 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Michael St.Paul FOR: Patricia Gehlen
Planning Technician Principal Planner

PROJECT:
S03-016
Barrio Esclalnte Subdivision
Residential Cluster Project
TRANSMITTAL:
DUE DATE: May 27, 2004


COMMENTS CODE SECTION/
DEVELOPMENT
STANDARD

1. An applicant has one (1) year from the date of approval of tentative plat to obtain approval of a final plat that complies with zoning and other development requirements in effect at the time of application. This final plat must be approved and recorded on or before April 20, 2005.

2. Please confirm with the County Recorder for the margin requirements of a final plat. I have been told that they might have changed those requirements. The City's Development Standards requires two inches (2") on the left margin and one-half inch (0.5") on the other three margins.
DS 2-03.6.1.B
3. The subdivision case number must be added to each sheet.
DS 2-03.6.1.K
4. This subdivision must be identified as a Residential Cluster Project (RCP) in the title block.

5. Add the following statement to the general notes: "This subdivision is subject to Ordinance No. C9-77-57 which established zoning in The Groves / Essex Gardens East Annexation Area."
DS 2-03.6.2.J
6. Please change the ASSURANCES signature line to "City of Tucson Development Services Department Director."
DS 2-03.6.3
7. Please identify the private road as Common Area 'A' along with the existing identifications.
DS 2-03.6.4.C
8. Common Area 'B' has been reduced from five thousand eight (5,108) square feet on the Tentative Plat to four thousand six hundred twenty five (4,625) square feet on the Final Plat. Please revise the Final Plat to match the approved Tentative Plat.

9. The title information provided on the CC&Rs must be identical to the information provided in the title block on the plan.
05/24/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: May 24, 2004


RE: Assessor’s Review and Comments Regarding Final Plat
S03-016 Barrio Escalante T141532 (136-38)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Per phone conference with Mt. Charles Corrales, the following items will be corrected or added.
The perimeter line will be made a solid line.
The street will be labeled as Common Area “A”.
The missing dimensions will be added to Common Areas “C” & “D”.
If there area any questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.





Susan C. King
06/02/2004 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
06/02/2004 LOREN MAKUS ENGINEERING REVIEW Denied DATE: June 2, 2004
TO: Craig Gross; CDRC Coordinator
SUBJECT: Barrio Escalante Final Plat Engineering Review
REVIEWER: Loren Makus
ACTIVITY NUMBER: S03-016


SUMMARY: The Final Plat has been reviewed by Development Services Department Engineering Division. We do not recommend approval of the Final Plat at this time. The following comments must be addressed before the Final Plat can be approved.

Final Plat Comments:
1. General note 3 does not match the information given on the approved tentative plat. Revise the note to be consistent with the tentative plat.
2. Provide the correct label for the signature lines in the assurances section. (DS 2-03.6.3)
3. Provide closure calculations for the boundary data for the project. Include a current title report with the resubmittal.
4. Labels on common areas 'C' and 'D' and their description in the "Square Foot Table" do not match the approved tentative plat and do not match each other. Revise the labels and the table to be consistent with the tentative plat.
5. Show all proposed and existing easements that will remain with the project including the drainage easement along the south boundary as shown on the approved tentative plat.
6. Two curves are labeled as curve 3. Clarify which curve label and description apply to each curve.
7. Clearly label common area 'A'.
8. Include the subdivision case number on each sheet near the title block.
9. Provide a bearing for the 45.00' tie to the monument in Poinciana Drive.
10. DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Provide a complete assurances packet for approval.
If you have any questions or to set up a meeting, call me at 791-5550, extension 1161.

Loren Makus, EIT
Senior Engineering Associate
Engineering Division
Development Services
06/18/2004 CRAIG GROSS PIMA COUNTY WASTEWATER Approv-Cond DEVELOPMENT REVIEW DIVISION
201 N. Stone Avenue, 2nd Floor
Tucson, Arizona 85701-1207

CARMINE DEBONIS, JR. Phone: (520) 740-6586
Director FAX: (520) 740-6380


May 24, 2004

TO: Charles Corrales, Steve Corrales Engineering Corporation

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Barrio Escalante, Lots 1-46
- Submittal
S03-016


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use:


Under separate cover, a private Sewer Service Agreement for the proposed number of residential lots has been sent to your office. After three original Sewer Service Agreements have been signed by the Owner of Record, the three originals must be returned to this office, before we can approve the final plat.

2. A resubmittal of bluelines to this office is not necessary. We will approve this submittal of the final plat, when the three signed and notarized originals of the Sewer Service Agreement are returned to this office. Until that time, our records will reflect that this project is NOT APPROVED.


If you wish to discuss the above comments, please contact me at the phone number provided on the first sheet.

Copy: Project
06/18/2004 CRAIG GROSS PIMA COUNTY WASTEWATER Approv-Cond June 28, 2004

TO: Charles Corrales, Steve Corrales Engineering Corporation

THRU:


FROM: ____________________________________
representing the Pima County
Departments of Wastewater Management and Environmental Quality

SUBJECT: Barrio Escalante, Lots 1-46 and Common Areas A-D
- Submittal
S03-016


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The three signed and notarized Sewer Service Agreements for this project have been received by this office. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature.