Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - FINAL PLAT REVIEW
Plan Number - S03-012
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2003 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/20/2003 | JIM TATE | ENGINEERING | REVIEW | Denied | TO: Craig Gross; CDRC Coordinator DATE: August 20, 2003 SUBJECT: Second Engineering review of the Sierra Madre Final Plat. The activity number is S03-012. SUMMARY: The Final Plat was received by Engineering on August 19, 2003. Engineering has reviewed the received item and does not recommend approval of the Final Plat RESUBMITTAL REQUIRED: FP The next submittal must address the following items: FINAL PLAT 1. Page 3 Building C typical unit detail calculates to 570.51 sq.ft. The plan shows 570.92. The volume specification is also incorrect. 2. The south boundary distance shows 293.80 ft. The Boundary Closure Calcs show 283.80. 3. Note No. 1 on Sheet 3 says, UNITS 47 & 48 ARE 2-BEDROOM UNITS". The plan does not show any units labeled 47 and 48. James C. Tate, P.E. Civil Engineer |
| 08/26/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: Sierra Madre Subdivision S03-0012 Final Plat - condominium conversion TRANSMITTAL: August 26, 2003 DUE DATE: September 2, 2003 1. Note No. 1 on Sheet 3 reads: "Units 47 & 48 are 2-bedroom units" but units 47 and 48 cannot be found on the plat. 2. Revise the south lot line boundary dimension to be correct (should read 293.8 feet). DS 2-03.6.5.C.5 3. A two-inch margin must be maintained along the left side and a ½-inch margin on all other sides. The left and top edges of the drawings do not comply. Please revise to provide correct margins on recorded copies. DS 2-03.6.1.B If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 08/28/2003 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S03-012 SIERRA MADRE / REVISED FINAL PLAT DATE: August 26, 2003 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1: Correct Scale on pg. 3. 2: Correct Condominium Unit Numbers on pg. 3. |