Plan Number: S03-007
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - FINAL PLAT REVIEW

Plan Number - S03-007
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/15/2003 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/19/2003 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved From: "Castillo, Liza" <LCastillo@tep.com>
To: 'Craig Gross' <cgross1@ci.tucson.az.us>, 'Ferne Rodriquez' <frodrig2@ci.tucson.az.us>
Date: 12/18/2003 4:36:05 PM
Subject: SILVERBELL TRAILS, S03-007

SUBJECT: SILVERBELL TRAILS
Lots 1-42
S03-007

The Final Plat for the subject project will meet this Company's easement
requirements.
Please forward any resubmittals of the final plat to this office.

Electric service will be provided to this subdivision in accordance with the
rules and regulations approved by the Arizona Corporation Commission.

Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 884-3879
Pager: (520) 218-6565
Fax: (520) 770-2002
12/29/2003 ELIZABETH EBERBACH ENGINEERING REVIEW Denied SUBJECT: Silverbell Trails Final Plat 2nd Submittal Engineering Review
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: S03-007

SUMMARY: The boundary closure sheet, revised Final Plat, copy of the CC&R's, and assurance paperwork were received by Engineering on December 15, 2003. Development Services Department Engineering Division has completed a review of the received items and does not recommend approval until the remaining comments are adequately addressed.

FINAL PLAT COMMENTS:
1) DS Sec.2-03.6.4.I: As stated in previous comments, detention/retention areas must be shown in a surveyable and readily retraceable manner. The basin area is labeled as "DRAINAGE" on the Final Plat common area title block descriptions; the basin area needs to be called out as a "RETENTION / DETENTION BASIN".
2) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. If the descriptions of the common areas are changed on the Final Plat title block (due to above comment), the Exhibit "A" legal description in both the AMENDMENT TO TRUST / THIRD PARTY TRUST and the AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST must be revised to match the Final Plat title block descriptions. The CC&R's description of the subdivision needs to also match.
3) DS Sec.2-03.6.6: Provide an original, signed copy of the Covenants, Conditions, and Restrictions (CC&Rs) describing retention/detention basin maintenance, with verbiage within the CC&R's per DS Sections 10-02. XIV.14.3.2 & 3. Otherwise, the verbiage from sections 10-02. XIV.14.3.2 & 3 needs to be added to the Final Plat as general notes. See attached copy of this section.
4) With the submittal of the final plat mylar, any references to 2003 shall be updated to 2004. Also, any assurance paperwork will need to be updated.

The next submittal should address all the above items. Please submit the revised assurance package items, revised CC&R's, and the revised Final Plat. If you have questions or would like to set up a meeting to go over these comments, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department