Plan Number: S03-001
Parcel: Unknown

Address:
8200 E STELLA RD

Review Status: Completed

Review Details: RESUBMITTAL - FINAL PLAT REVIEW

Plan Number - S03-001
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/28/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/01/2005 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: LAKESIDE RIDGE
Lots 1-68
S03-001

The Final Plat for the subject project will meet this Company's easement
requirements.
Please forward any resubmittals of the final plat to this office.

Electric service will be provided to this subdivision in accordance with the
rules and regulations approved by the Arizona Corporation Commission.


Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
02/01/2005 LAITH ALSHAMI ENGINEERING REVIEW Approv-Cond Laith Alshami, 02/01/2005, Engineering and Floodplain Review

SUBJECT: Lakeside Ridge
S03-001, T14S, R15E, SECTION 28


RECEIVED: Final Plat and CC & R's on January 28, 2005

The subject project has been reviewed. The Final Plat and the CC & R's are recommended for approval pertaining to Engineering and Floodplain subject to addressing the following comments on the Final Plat Mylar:

1. Revise the location map to show the location of Sarnoff Drive correctly.
2. Since all dimensions shown on the Plat are measured, add the letter (m) next to all dimensions (D.S. 2-03.6.5.C.5).
3. Dimension the Boundary of the proposed Atterbury Wash dedication.
4. Submit the most recent Title Report with the Final Plat Mylar for the processing of Assurances.
02/02/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-001 LAKESIDE RIDGE/REVISED FINAL PLAT
DATE: February 2, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Correct sections on Location Map.

Change 17-4 to 54-19 on Location Map.

Change Sarnoff Drive to Camino Seco on Location Map.















jg
02/02/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-001 LAKESIDE RIDGE/REVISED FINAL PLAT
DATE: 3/11/05



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
02/22/2005 PETER MCLAUGHLIN ZONING REVIEW Approved
02/25/2005 MARILYN KALTHOFF PIMA COUNTY WASTEWATER Approv-Cond February 25, 2005

To: John Evans, P.E., Jae Consulting Engineers

Thru: Craig Gross, CDRC Manager
City of Tucson Development Services Department

From: ____________________________________
Tim Rowe, P.E. (520-740-6563) representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Lakeside Ridge, Lots 1-68
Final Plat - 2nd Submittal
S03-001


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


We have sent to your office under separate cover three originals of a Sewer Service Agreement for the proposed number of residential lots. Once the three originals of the Agreement have been signed by the Owner of Record, and notarized, they must be returned to this office, so that this office will be able to approve the sewer improvement plan for this project (G-2004-156).

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter.


CC: G-2004-156
02/25/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed