Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S02-052
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/21/2003 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/29/2003 PETER MCLAUGHLIN ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Peter McLaughlin Senior Planner

FOR: Patricia Gehlen
Principal Planner


PROJECT:
Canterbury Ranch RCP
S02-052
Tentative Plat

TRANSMITTAL: July 29, 2003
DUE DATE: August 4, 2003

The Zoning Review Section at Development Services verifies that the tentative plat meets the requirements of the Land Use Code, subject to the following changes. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.


1. Revise building setback notes as follows: The required interior bldg. setbacks (for both side and rear lot lines) are 3 feet. Revise the term "front" to read "street perimeter yard", this will include the "side street" building setback, as it is also "the greater of 21 feet or (H) measured from the outside edge of nearest adjacent travel lane." Remove the terms "side" in referencing the street perimeter yard setback.
LUC 3.2.6.5

2. The lot numbers are not correctly listed in the perimeter building setback notes. For example, lots 57 and 103 should not be listed as a perimeter lots. Please revise.
LUC 3.2.6.4

Should the CDRC recommend approval of the tentative plat, please have the applicant submit sign-off copies for approval.

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
08/04/2003 ELIZABETH EBERBACH ENGINEERING REVIEW Denied SUBJECT: Engineering review of the Canterbury Ranch Tentative Plat third submittal
ACTIVITY #: S02-052

SUMMARY: Meeting with Robert and David Little on July 25, 2003 to go over responses to comments. The revised Tentative Plat, Landscape Construction Documents, Native Plant Preservation Plan, and Drainage Report, were received by Engineering on July 21, 2003. Development Services Department Engineering Division has completed the review of the received items and does not recommend approval at this time. The Drainage Report was reviewed for Tentative Plat purposes only.

TENTATIVE PLAT COMMENTS:
1) Provide infiltration calculations and a copy of the soils report with results from the percolation tests. The Tentative Plat can only be approved once this has been reviewed and accepted. If basin does not show acceptable infiltration rates, other design may be required. Please also note that additional percolation testing may be required at post-grading construction inspection.
2) Permits & Codes have stated that they are not opposed to the proposed RCP in the Los Reales Road Extension right-of-way. However, it was requested that it be sized such that it will safely convey the design event and not negatively impact upstream and downstream properties. This should be covered in the drainage report submitted with the Tentative Plat.
3) Clarify design that takes into account flows from Window Rock East that impacts site from the east boundary of this project, for both existing conditions, as well as, full build-out conditions as shown on approved grading plans. Quantify and show the location of all existing flows that enter the property.
4) Correct any elevation call-outs for basin floors as discussed in the meeting.

The next submittal should address all the above items. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Section
Development Services Department
08/06/2003 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this T.P.

1. The symbol used for new traffic signs is not correct IAW SD 100. The symbol was corrected on the cover sheet but not on the interior sheets. (sht 3 of 7)
2. See DS 3-01.0 figure 20 for extent of no parking zones in cul-de-sacs. The no parking area is from the PRC to a point directly across the centerline of the traveled way. Show no parking signs in cul-de-sacs on sht 3 of 7 in the appropriate locations.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
08/06/2003 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved COMPREHENSIVE PLANNING TASK FORCE COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S02-052 Cantebury Ranch 08/04/03

( X ) Tentative Plat
( ) Development Plan
( X ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C15-95-16

NEIGHBORHOOD PLAN: Rincon/Southeast Subregional Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: August 4, 2003

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
( X ) No Additional Comments - Complies With Planning Comments Submitted on: 5/12/03
( X ) No Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: JBeall 791-4505 DATE: 7-28