Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW
Plan Number - S02-048
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/17/2003 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/20/2003 | JIM TATE | ENGINEERING | REVIEW | Approved | TO: Craig Gross; CDRC Coordinator DATE: October 20, 2003 SUBJECT: Third Engineering review of the Navajo Place Apartments Tentative Plat. The activity number is S02-048. SUMMARY: The Tentative Plat was received by Engineering on October 17, 2003. Engineering has reviewed the received item and recommends approval of the Tentative Plat. APPROVAL: TP GENERAL COMMENTS 1. The Drainage Report was reviewed for Tentative Plat purposes only. 2. Please include the Assurance Package with the Final Plat submittal. This package must include the original Third Party Trust, the original Amendment to Trust, a copy of the Trust Agreement, a copy of the Deed, and a recent Title Report. 3. Include a copy of the CC&Rs with the Final Plat submittal. The specific maintenance notes specified in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.3.2 must be included in the CC&Rs. The term "owner" in the maintenance notes must be changed to "Homeowners Association". 4. Please provide a copy of the boundary closure calculations with the Final Plat submittal. 5. A Grading Plan and Permit will be required. Proposed grading in excess of 5,000 yards is designated "engineered grading" and a soils engineering report is required with the Grading Plan submittal. IBC Chapter 36, Section 9. The Soils Report must also address the requirements detailed in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.2.6. The Grading Plan must show conformance with all the requirements of proposed development in a floodplain. Tucson Code Chapter 26 Floodplain and Erosion Hazard Management. 6. Proposed fills in excess of two feet above existing grade at any location in the outer one hundred feet of the developing site adjacent to residentially zoned property require the procedure outlined in IBC Chapter 36 Section13.1. This process must be complete prior to Grading Plan approval. 7. A Flood Use Permit is required prior to Grading Plan approval. 8. Proposed developments disturbing areas exceeding 1 acre are subject to NPDES requirements. Contact Patricia Gilbert, 791-5550 for submittal requirements. The NPDES submittal must accompany the Grading Plan submittal. James C. Tate, P.E. Civil Engineer |
| 10/23/2003 | TIM ROWE | PIMA COUNTY | WASTEWATER | Denied | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT DEVELOPMENT REVIEW DIVISION 201 N. Stone Avenue, 2nd Floor Tucson, Arizona 85701-1207 CARMINE DEBONIS, JR. Phone: (520) 740-6586 Director FAX: (520) 740-6380 October 10, 2003 TO: Debbie S. Shinstine, P.E., THRU: Craig Gross, City of Tucson Development Services FROM: Subhash Raval, P.E., Division Manager Pima County Development Review & Technical Services Division (Wastewater) SUBJECT: Navajo Place Apartments, Lots 1-3 Tentative Plat - 2nd Submittal S02-048 We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use: 1. Sheet Two: Use alternate line weight or type to differentiate 6" private sewer lines from other design lines shown, and to show where sewer lines terminate. 2. Sheet Two: Add symbol for key note #13 to new manhole, if appropriate, or remove from key notes if not applicable. 3. Sheet Two: HCS to lot 2 is labeled 6", however, keynote symbols indicates 4". Correct appropriately. 4. Sheet Two: Show how the existing duplex is connected to the public sewer system. The Cragin-Keeling Area Plan provides general design policy only, and does not specify sewer locations. Please field verify. 5. Note #38 does not satisfy comment #8 from the previous response letter dated January 15, 2003. Please provide the following information as requested: PCWWM’s records for the adjacent property to the northwest (341 East Navajo) indicate that the private sewer lines serving this property cross the property being subdivided. Please see the attached sewer connection card. Please take all of the following actions: 1. Field verify the information shown on the sewer connection card. 2. Show all existing private sewer lines that serve 341 East Navajo and cross the property being subdivided, and how these private sewer lines connect to the public sewer system 3. Show any existing private sewer easements, and any new private sewer easements necessary to maintain these private sewer lines. 6. We will require a complete set of the revised bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. The next submittal of this project will be the third (3rd) submittal. Please include a $78.00 check for the wastewater review fees (made out to PIMA COUNTY TREASURER) with the revised set of bluelines and response letter. If other sheets are revised in such a manner that the sewer design is impacted, please adjust the review fee accordingly. If you wish to discuss the above comments, please contact me Brandon Matheson at 740-6315. Subhash Raval, P.E., Division Manager Pima County Development Review & Technical Services Division (Wastewater) SR/BM/dk Copy: Project |
| 10/30/2003 | DAN CASTRO | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Plans Coordination Office Development Services Department PROJECT: Navajo Place Apartments S02-048 Tentative Plat FROM: Dan Castro Senior Planner FOR: Patricia Gehlen Principal Planner Zoning Review Section Development Services Dept. TRANSMITTAL: October 29, 2003 DUE DATE: October 30, 2003 COMMENTS CODE SECTION/ DEVELOPMENT STANDARD The Zoning Review Section verifies that the tentative plat meets the requirements of the Land Use Code. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Dan Castro at (520) 791-5608. I:/tentplat2002/S02-048tnptappr.doc |
| 10/30/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 11/07/2003 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | COMPREHENSIVE PLANNING TASK FORCE COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT S02-048 Navajo Place Apartments 11/06/03 ( X ) Tentative Plat ( ) Development Plan ( X ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: CDRC: C12-83-51 NEIGHBORHOOD PLAN: Cragin-Keeling Area Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: October 30, 2003 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (X ) No Additional Comments - Complies With Planning Comments Submitted on: 09/17/03 ( X ) No Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: JBeall 791-4505 DATE: 10/30/03 |