Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: S02-043
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S02-043
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/20/2003 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/27/2003 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S02-043 MESQUITE COVE / TENTATIVE PLAT
DATE: June 24, 2003

The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.***
07/03/2003 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: S02-043
Mesquite Cove, Lots 1 - 71 and Common Area "A", "B", and "C"
Tentative Plat - Residential Cluster Project

TRANSMITTAL: July 1, 2003

DUE DATE: July 3, 2003

COMMENTS:

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is October 17, 2003.

2. Due to amended rezoning conditions specifically condition 13, vehicle parking is to be provided on both sides of the street. Remove all notes that state "No Parking" and add the vehicle parking space symbols on the opposite side of the street where required. (Add the street cross section symbol to sheets 4 and 5) DS 2-03.2.4.G

3. Due to the change in concept for this development Mayor and Council did in fact amend the rezoning conditions. Please revise the rezoning conditions on sheet two of nine. The rezoning conditions must be listed verbatim. In addition please provide a separate response memo stating how the conditions of rezoning have been met. (Previous Comment: Per a conversation with Craig Gross regarding this project the proposed change from a Mobile Home Park to Single Family Home subdivision requires an approval by Mayor and Council because it is a change in concept. The change in concept is subject to further conditions placed on the site and will need to be addressed. If this is the case, further comments may be forthcoming on subsequent reviews.)

4. Provide a copy of the landscape plan for the landscape plans for the landscape and zoning reviewers in to review and to verify rezoning conditions related to landscape issues and requirements have been addressed.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C:\planning\cdrc\tentativeplat\S02043tp3.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Tentative plat, landscape plan and response letters as requested