Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S02-042
Parcel: Unknown

Address:
4083 N STONE AV

Review Status: Completed

Review Details: CDRC RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S02-042
Review Name: CDRC RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/15/2002 FERNE RODRIGUEZ START INITIALIZE THE WORKFLOW Completed
11/21/2002 KAY MARKS PIMA COUNTY ADDRESSING Approved PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
201 N. Stone Ave, 1st Floor
Tucson, Arizona 85701-1207

KAY MARKS
ADDRESSING SUPERVISOR
PH: 740-6480
FAX #: 740-6370



TO : CITY PLANNING
FROM : KAY MARKS, ADDRESSING SUPERVISOR
SUBJECT : S02-042 STONE CURVES-A CO-HOUSING NEIGHBORHOOD/REVISED TENATIVE PLAT
DATE : November 21, 2002


***********************************************************************************************************

The above referenced project has been reviewed by this Division for all matters pertaining to street naming/ addressing, and we hereby approve this project.




***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County=s Geographic Information System. Your Support is greatly appreciated.***
11/25/2002 DAVID RIVERA DEVELOPMENT SERVICES ZONING Approv-Cond TO: Plans Coordination Office
Development Services Department

PROJECT: S02-042
Stone Curves Co-Housing
Tentative Plat

FROM: David Rivera
Senior Planner

FOR: Patricia Gehlen
Principal Planner
Zoning Review Section

TRANSMITTAL: November 25, 2002

DUE DATE: November 29, 2002

COMMENTS:

The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

1. Remove the BOOK and PAGE annotation from the lower right corner of all plan sheets. The Book and Page annotation is to be placed on the final plat sheets.

If you have any questions about this transmittal, please call David Rivera at (520) 791-5608.

DGR C:\planning\cdrc\tentativeplat\S02042tpca.doc
11/27/2002 JIM TATE DEVELOPMENT SERVICES ENGINEERING Approved DATE: November 27, 2002
TO: Craig Gross; CDRC Coordinator
FROM: James C. Tate, P.E.

SUBJECT: Engineering review of the Stone Curves Tentative Plat. The activity number is S02-042.

SUMMARY: Engineering recommends approval of the Tentative Plat and the Drainage Report.

APPROVAL: TP, DR

GENERAL COMMENTS

1. The Drainage Report was reviewed for Tentative Plat purposes only.

2. A Grading Plan and permit is required. Proposed grading in excess of 5,000 yards will require a soils engineering report and an engineering geology report with the Grading Plan submittal. Proposed fills in excess of two feet above existing grade at any location in the outer one hundred feet of the site adjacent to residentially zoned property will require the procedure outlined in IBC Chapter 36 Section 13.1

3. NPDES requirements apply to projects larger than 5 acres. For submittal requirements contact Loren Makus, 791-4251

4. Include the Assurance Package with the Final Plat submittal.

5. Include a copy of the CC&Rs with the Final Plat submittal. The maintenance notes specified in the Standards Manual for Drainage Design and Floodplain Management, SMDDFM, 14.3.2 must be included on the Final Plat or in the CC&Rs.

6. Provide a copy of the boundary closure calculations with the Final Plat submittal.
11/27/2002 JOE LINVILLE DEVELOPMENT SERVICES LANDSCAPE Approved
12/05/2002 FRODRIG2 PIMA COUNTY WASTEWATER Approved PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
DEVELOPMENT REVIEW DIVISION
201 N. Stone Avenue, 2nd Floor
Tucson, Arizona 85701-1207

CARMINE DEBONIS, JR. Phone: (520) 740-6586
Director FAX: (520) 740-6380
December 04, 2002

TO: Thomas Saylor-Brown, SBBA

THRU: Craig Gross, City of Tucson Development Services

FROM: Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division

SUBJECT: Stone Curves, Units 1-48
Development Plan / Tentative Plat
D02-0020 / S02-042



We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use:

PREVIOUSLY IDENTIFIED DEFICIENCIES:

1. Item 8 of my review letter dated September 20, 2002 was not adequately addressed. Assessor’s Parcel Number (APN)105-12-050A will not have adequate access to the public sewer system, if the existing public sewer lines within the development plan boundaries are abandoned for use as private sewers, as proposed. And, as of this time, PCWWM has not agreed to this abandonment.

Public sewer service to a lot line of APN 105-12-050A, or legal access to a public sewer line within 50' of the lot lines of APN 105-12-050A, must be provided for PCWWM to agree to the abandonment of the existing public sewer lines.

Alternately, a written release of public sewer service, signed by the owner of APN 105-12-050A and notarized, may be submitted to this office for consideration. APN 105-12-050A and the parcel to the south (APN 105-12-051A) appear to have the same owner, and APN 105-12-051A will have adequate access to the public sewer system, if PCWWM agrees to abandon the existing public sewer lines that are within development plan boundaries. If the owner of these two parcels intends to combine these two parcels into one, he or she may be amenable to providing such a release.


NEW DEFICIENCIES:

2. Label the existing sewer lines with their plan numbers (G–81-22 and I-82-58).

3. Show the existing 15' sewer easement recorded in Docket 10174, Page 3029 properly and in the correct location on Sheet 2. Per the legal description of this easement, it is "T" shaped.
This easement should also be over the existing public sewer lines. Per Sheet 7, it is not.

Note: If this easement is not over the existing public sewer lines, and the existing public sewer lines will not be abandoned, a 20' public sewer easement will need to be granted by separate instruments for these sewer lines. PCWWM no longer accepts 15' public sewer easements.

Revise as necessary.


ADDITIONAL INFORMATION:

4. We will require a revised development plan/tentative plat and response letter addressing the above referenced comments. Additional comments may be forthcoming.

5. Due to the number of proposed condominium units being proposed, a Sewer Service Agreement will need to be prepared for this project. This Agreement will be prepared during the final platting process for this project.

If you wish to discuss the above comments, please contact me at 740-6563.




Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division


TR/tr

Copy: Project