Plan Number: S02-040
Parcel: Unknown

Address:
3630 E FELIX BL

Review Status: Completed

Review Details: CDRC - FINAL PLAT REVIEW

Plan Number - S02-040
Review Name: CDRC - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/18/2002 FERNE RODRIGUEZ START INITIALIZE THE WORKFLOW Completed
11/21/2002 KAY MARKS PIMA COUNTY ADDRESSING Approved PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
201 N. Stone Ave, 1st Floor
Tucson, Arizona 85701-1207

KAY MARKS
ADDRESSING SUPERVISOR
PH: 740-6480
FAX #: 740-6370



TO : CITY PLANNING
FROM : KAY MARKS, ADDRESSING SUPERVISOR
SUBJECT : S02-040 DREXEL MANOR/FINAL PLAT
DATE : November 21, 2002


***********************************************************************************************************

The above referenced project has been reviewed by this Division for all matters pertaining to street naming/ addressing, and we hereby approve this project.


NOTE: ON FINAL MYLAR:

1.) Change “Los Ranchitos Book 8, Page 71” to “Los Ranchitos Number 7 Book 8, Page 71” on pg.1.





***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County=s Geographic Information System. Your Support is greatly appreciated.***
11/27/2002 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied 3950 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


Telephone: 520-884-3879
Fax: 520-770-2002
WR#94304 November 22, 2002



Mr. Derek Roberts
Landmark Engineering, Inc.
300 N. Main Avenue, Suite 104
Tucson, AZ 85701

Dear Mr. Roberts:

SUBJECT: Drexel Manor
Lots 1-140
S02-040

Tucson Electric Power Company (TEP) has received the Final Plat for review dated stamped “Preliminary” by the City. This Company is unable to approve the plat at this time.

An electrical design to determine our easement requirements will be provided on the Approved Tentative Plat within twenty-two (22) working days upon receipt of the plat. At the customer’s request, a design can be provided prior to the Approved Tentative Plat, however, once a design is provided, any design changes may be billable to the developer.

Please contact me at (520) 884-3879 if you have any questions.

Sincerely,



S. Glynda Rothwell
Right-of-Way Agent
Land Management

sgr
cc: C. Gross, City of Tucson
Dennis Wianas, Schmac Properties, Inc.
12/10/2002 FRODRIG2 COT NON-DSD REAL ESTATE Approved No objection
12/16/2002 PETER MCLAUGHLIN DEVELOPMENT SERVICES ZONING Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
Drexel Manor RCP
S02-040
Final Plat

TRANSMITTAL: December 16, 2002
DUE DATE: December 16, 2002


1. Reference recorded subdivisions by book and page number in the location map.
DS 2-03.6.1.D.2

2. Revise the City Limits line to be correct on the drawing. It should be corrected to follow Felix Boulevard along its southern right-of way line to the northwest of the site.

3. Remove all of the zoning indicators from all sheets of the final plat. They are not accurate and are not required as part of a final plat.
DS 2-03.6.1.H

4. Provide the square footage for common area "A" on the drawing.
DS 2-03.6.4.D

5. There is no printed name/signature line provided in the dedications block. Revise by adding signature line to the dedications paragraph.
DS 2-03.6.3.C


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
12/17/2002 FRODRIG2 PIMA COUNTY WASTEWATER Denied PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
DEVELOPMENT REVIEW DIVISION
201 N. Stone Avenue, 2nd Floor
Tucson, Arizona 85701-1207

CARMINE DEBONIS, JR. Phone: (520) 740-6586
Director FAX: (520) 740-6380
January 15, 2003

TO: Derek Roberts, Landmark Engineering

THRU: Craig Gross, City of Tucson Development Services

FROM: Subhash Raval, P.E., Division Manager
Pima County Development Review & Technical Services Division (Wastewater)

SUBJECT: Drexel Manor
Tentative Plat - 2nd Submittal
Final Plat - 1st Submittal
S02-040



We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use:

Per our conversation on January 8, 2003 corrected plans were to be delivered to us for review; however, as of date we have not received them. Please make the following revisions. Be advised, the review of the Final Plat will be done with your resubmittals.

1. Run a sewer line stub from Drexel Manor Place into Drexel Road for flow-through.

Please Note: No oversizing credits can be given for the use of 10" sewer lines in this subdivision, as the 10" lines are not necessary to carry the expected flow-through. The 10" lines have been used only to meet minimum slope requirements.

2. Common Area A will need to be granted to the public as a public sewer easement on the final plat.

3. A Sewer Service Agreement will be prepared with the submittal of your revised Final Plat

If you wish to discuss the above comments, please contact Tim Rowe at 740-6563.



Subhash Raval, P.E., Division Manager
Pima County Development Review & Technical Services Division (Wastewater)

SR/SR/dk
Copy: Project
12/17/2002 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor’s Office
Mapping Department

DATE: December 16, 2002


RE: Assessor’s Review and Comments Regarding Final Plat
S02-040 Drexel Manor T151404 (140-05)

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor’s Office requirements.
_______ Plat does not meet Assessor’s Office requirements.


COMMENTS: Thank you for your submittal. Per phone conversation with Mr. Dan Elder, the following items will be corrected before recording of the plat.
Common Area “B” will be added to the title blocks.
The square footage for Common Area “A” will be added.
Add the length and the central angle to the Common Area “B” on sheet 2 that is adjacent to lot 116.
If there are any questions, please contact Susan King at 740-4391.

NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.






Susan C. King
12/31/2002 ELIZABETH EBERBACH DEVELOPMENT SERVICES ENGINEERING Denied SUBJECT: Drexel Manor Final Plat review
REVIEWER: Elizabeth Eberbach
DATE: December 31, 2002
ACTIVITY NUMBER: S02-040

SUMMARY: The Final Plat and CC&R package were received by Engineering on November 18, 2002. The assurance package was received October 19, 2002. Engineering has reviewed the received items and does not recommend approval of the Final Plat until the following items have been addressed.

FINAL PLAT COMMENTS
1) City of Tucson Development Standards (DS) Section No.2-03.6.1.G: Place the words "Book ____ Page ____" in the upper right corner outside the margin line. Also, there is missing text in upper right corner next to book & page on sheet 3.
2) DS Sec.2-03.6.1.H.1: In title block, provide descriptions of all common areas.
3) DS Sec.2-03.6.1.J: Clarify linetypes for COT/PC jurisdictional limits and matchlines.
4) DS Sec.2-03.6.1.L: EXISTING LOT NUMBERS are described with dashed lines in legend and shown as solid lines in plan view; clarify.
5) DS Sec.2-03.6.2&J: Add Tentative Plat General Notes 12, 17, 20 and 21 as Final Plat General Notes.
6) DS Sec.2-03.6.3.A: Provide seal and signature for surveyor.
7) DS Sec.2-03.6.3.B.4: On sheet 1, the title company information and signature lines shown under "ASSURANCE" shall be placed under "DEDICATION".
8) DS Sec.2-03.6.3.C: The following BENEFICIARY block must be included on the title page: "BENEFICIARY, The beneficiary of (Title Company Name and Trust Number) is (Name and Address)."
9) DS Sec.2-03.6.3.D: Under RECORDING DATA, provide more space for County Recorder Seal. Also, make sure "2002" is updated to "2003".
10) DS Sec.2-03.6.4.D: On sheet 2, provide Common Area "A" square feet and also label area on sheet 3.
11) DS Sec.2-03.6.4.G: Continue the one-foot no-vehicular access easements where driveway restrictions are present. According to attached page from COT Code Chapter 25-38(a), in residential zones, driveway curb cuts shall be a minimum distance of 4 feet from end of curb return. Extend 1-foot Access Control Easements for those lots affected (lots 8, 9, 33, 34, 60, 61, 85, and 86).
12) DS Sec.2-03.6.4.I: Delineate all detention/retention areas in a surveyable manner. Provide certification with seal and signature for registered engineer on cover sheet.
13) DS Sec.2-03.6.5.B: Clarify the following dimensions:
a) indicate tract boundary lines with accurate dimensions that match title report;
b) show all easements including those shown on approved Tentative Plat;
c) label section number for section corner for BCSM at Section 4 on sheets 1 and 3;
d) provide curve data for C13 on sheet 3.
14) DS Sec.2-03.6.5.C.2: Please provide boundary closure calculations.
15) DS Sec.2-03.6.5.C.5: Indicate whether the distances and bearings between all monuments are measured or calculated.
16) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. Update the assurance package to include Common Area "B" in recitals and exhibits. Also, for this and future projects, please provide an 8½" by 11" location map sheet for assurance submittals that go to Mayor & Council.
17) DS Sec.2-03.6&7.0: The final plat must conform to the approved tentative plat in lot configuration, design, and required conditions of development. The final plat approval can not occur until tentative plat approval. Submittal of the final plat prior to approval of the tentative plat is done at the applicant's risk since changes could be required of the tentative that may affect the final plat.

The next submittal should address all the above items. Submit the revised Final Plat, copy of approved tentative plat, updated assurance package, and updated title report. If you have any questions, you may schedule a meeting with me to go over your comments, or call me at 791-5550 extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Section
Development Services Department
City of Tucson