Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S02-037
Parcel: Unknown

Address:
102 W ROGER RD

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S02-037
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2003 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/18/2003 ELIZABETH EBERBACH ENGINEERING REVIEW Approved SUBJECT: Roger Plaza Tentative Plat Engineering Review
REVIEWER: Elizabeth Eberbach
DATE: July 17, 2003
ACTIVITY NUMBER: S02-037

SUMMARY: The architect, representative, and the engineer attended meetings on June 30, and July 11, 2003 to go over last submittal comments. The fifth submittal of the Roger Plaza revised Tentative Plat / Development Plan, revised Drainage Report, and revised Landscape Plan were received by Engineering on July 14, 2003. Engineering has reviewed the received items and recommends approval of the Tentative Plat / Development Plan. The Drainage Report and Grading Plan were reviewed for Tentative Plat/ Development Plan purposes only.

TENTATIVE PLAT COMMENTS:
1) City of Tucson Development Standards (DS) Section No.2-03.6.6: Please recognize that an original copy of the CC&R's will be required at Final Plat review stage. The maintenance notes must be included on the Final Plat or in the CC&Rs per Standards Manual for Drainage Design and Floodplain Management section 14.3.2.
2) IBC Chapter 36, Section 9: A grading plan submittal will be required. Basin maintenance access will need to be shown on grading plan, per DS Sec.10-02.14.3.4.
3) DS Sec.2-03.7.1.G: Include the Assurance Package with the Final Plat submittal.

If you have any questions, please call me at 791-5550 extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
07/22/2003 PETER MCLAUGHLIN ZONING REVIEW Approv-Cond TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
Village on Roger
Apartments ( RCP )
26 W. Roger Road
S02-037
Tentative Plat

TRANSMITTAL: July 22, 2003
DUE DATE: June 28, 2003

The Zoning Review Section at Development Services verifies that the tentative plat meets the requirements of the Land Use Code, subject to the following changes. However, should there be any changes requested by other CDRC members, the approval is void, and we request copies of the corrected tentative plat to verify that those changes do not affect any zoning requirements.

1. Add the S02-037 case number near the title block in the lower right hand corner of all sheets, including sheet C2 and sheet C2.1
DS 2-03.2.2.B.1

Should the CDRC recommend approval of the tentative plat, please have the applicant submit sign-off copies for approval.


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.