Plan Review Detail
Review Status: Completed
Review Details: CDRC - FINAL PLAT REVIEW
Plan Number - S02-031
Review Name: CDRC - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/07/2002 | FRODRIG2 | START | INITIALIZE THE WORKFLOW | Completed | |
| 11/13/2002 | JIM TATE | DEVELOPMENT SERVICES | ENGINEERING | Denied | TO: Craig Gross; CDRC Coordinator FROM: Engineering SUBJECT: Engineering review of the Chantlalli Estates Final Plat. The activity number is S02-031. SUMMARY: The Final Plat was received by Engineering on November 8, 2002. Engineering has reviewed the received item and does not recommend approval of the Final Plat RESUBMITTAL REQUIRED: FP The next submittal should address the following items: FINAL PLAT 1. The Tentative Plat must be approved prior to Final Plat approval. Changes made to the Tentative Plat must be reflected on the Final Plat. 2. Please include the Assurance Package with the next Final Plat submittal. The Final Plat will not be approved until the Assurances have been approved. 3. Include the subdivison case number (S02-031) on the Final Plat. 4. Please include a copy of the property boundary closure calculations with the next Final Plat submittal. 5. The CC&Rs section 4.6 heading should read "responsibility of drainage easements and common areas". In Sections 4.6.1-4.6.4 the term "owner" should be replaced with "Association". This section (4.6) should be placed with Section 7, "Maintenance". James C. Tate, P.E. Civil Engineer |
| 11/27/2002 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT 201 N. Stone Ave, 1st Floor Tucson, Arizona 85701-1207 KAY MARKS ADDRESSING SUPERVISOR PH: 740-6480 FAX #: 740-6370 TO : CITY PLANNING FROM : KAY MARKS, ADDRESSING OFFICIAL SUBJECT : S02-31 CHANTLALLI ESTATES/FINAL PLAT DATE : November 26, 2002 ************************** The above referenced project has been reviewed by this Division for all matters pertaining to street naming/ addressing, and the following matters must be resolved prior to our approval: Change “Teocally Court” to “Teocalli Court.” Add Place to “Silverbell Tree” on pg. 2. Add file number to pages 2 and 3. 4.) Change “Ruston Hills (Lots 1-20) Bk 46, Pg 96” to “Bk 46, Pg 98” on pg. 3. |
| 12/02/2002 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Denied | COMMENTS ON FILE |
| 12/02/2002 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 RICK LYONS ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor’s Office Mapping Department DATE: November 29, 2002 RE: Assessor’s Review and Comments Regarding Final Plat S02-031 Chantlalli Estates T131333 (103-19) * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor’s Office requirements. _______ Plat does not meet Assessor’s Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR’S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan C. King |
| 12/02/2002 | DAN CASTRO | DEVELOPMENT SERVICES | ZONING | Approv-Cond | The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. Note the SCZ case number (SCZ-02-12) in the lower right corner of each sheet. 2. If the property is subject to the requirements of the Hillside Development Zone, add the note: "Prior to the issuance of any building permits, Hillside Development Zone approval is required for Lots ___." 3. Final plat may not be given final approval until the tentative plat is approved. |
| 12/10/2002 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Denied | Notify Real Estate with the date the final plat is scheduled for Mayor and Council. The City must convey to the Lawyers Title Trust #7977 all of parcel 103-19-001L simultaneously with the plat recording pursuant to Ordinance #9755. |
| 12/18/2002 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT DEVELOPMENT REVIEW DIVISION 201 N. Stone Avenue, 2nd Floor Tucson, Arizona 85701-1207 CARMINE DEBONIS, JR. Phone: (520) 740-6586 Director FAX: (520) 740-6380 January 24, 2003 TO: Wocky Redsar, Castro Engineering Corp THRU: Craig Gross, City of Tucson Development Services FROM: Tim Rowe, P.E., Development Review Engineer (Wastewater) Pima County Development Review Division SUBJECT: Chantlalli Estates, Lots 1-61 Common Areas A and B, and Block A Final Plat - 1st Submittal S02-031 We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use: 1. The signed Sewer Service Agreements for the above-referenced project have been received, therefore, we hereby approve the Final Plat. If you wish to discuss the above comments, please contact me at 740-6563. Tim Rowe, P.E., Development Review Engineer (Wastewater) Pima County Development Review Division TR/tr Copy: Project |