Review Status: Completed

Review Details: RESUBMITTAL - FINAL PLAT REVIEW

Plan Number - S02-017
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/24/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/25/2004 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S02-017A TIERRA VISTA PHASE II/REVISED FINAL PLAT
DATE: May 24, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***















Jg+
06/08/2004 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: TIERRA VISTA, PHASE II
Lots 14-19, 54-98, 286-298, 310-338, 345-371
S02-017

Tucson Electric Power Company (TEP) has reviewed the final plat dated May
21, 2004. TEP is unable to approve the plat at this time.

In order for this Company to approve the final plat, the following will be
required.

* An additional 5' easement is required to the west of Lot 366 where
there is an existing pull box.

Forward to this office the legal descriptions for the easements that are to
be abandoned.

Show the additional easement on the resubmittal of the final plat. Submit
two bluelines to the City of Tucson for TEP's final approval.


Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Cell Phone/Pager: (520) 904-2668
Fax: (520) 917-8400
06/08/2004 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: TIERRA VISTA, PHASE II
Lots 14-19, 54-98, 286-298, 310-338, 345-371
S02-017

The Final Plat for the subject project will meet this Company's easement requirements. The Final Plat was delivered to this office and dated 07/13/04.

Please forward any resubmittals of the final plat to this office.

Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission.



Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Cell Phone/Pager: (520) 904-2668
Fax: (520) 917-8400
06/16/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond (ORIGINALLY DENIED)

SUBJECT: Engineering review of the Tierra Vista Phase 2 Final Plat
ACTIVITY #: S02-017
REVIEWER: Elizabeth Eberbach
LOCATION: T15S, R14E, Section 9

SUMMARY: The revised copy of the Final Plat and the revised CC&R's were reviewed at a meeting with Landmark Engineering on July 15, 2004. Development Services Department Engineering Division recommends a conditional approval of the Final Plat.

FINAL PLAT CONDITIONS OF APPROVAL:
1) City of Tucson Development Standards (DS) Section No.2-03.3.2.D: Street abandonment for Britannia Way right-of-way must be done prior to, or concurrently with, the platting final plat.
2) DS Sec.10-02.14.3.2: Revise CC&R's to add basin maintenance information per this section. Otherwise, this section may be added as a general note to the Final Plat.
3) DS Sec.2-03.2.4.L.1: Show areas of detention/retention including 100-year ponding limits with water surface elevations. On sheet 2, the revised delineations for the ponding limits at the basin adjacent to lot 322 appear to be missing.
4) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. It was stated in the response letter that these are forthcoming. Address the following for other portions of the assurance package:
a) Revise any sheets of the assurance paperwork to reflect any change in descriptions of the common areas.
b) Provide AMENDMENT TO TRUST / THIRD PARTY TRUST.
c) Provide AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST.
d) Provide copy of sample Warranty Deed.

For resubmittal, please submit the remaining assurance package items, revised, signed copy of the CC&R's, and the revised Final Plat mylar. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
06/16/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond (ORIGINALLY DENIED)

SUBJECT: Engineering review of the Tierra Vista Phase 2 Final Plat
ACTIVITY #: S02-017
REVIEWER: Elizabeth Eberbach
LOCATION: T15S, R14E, Section 9

SUMMARY: The revised copy of the Final Plat and the revised CC&R's were reviewed at a meeting with Landmark Engineering on July 15, 2004. Development Services Department Engineering Division recommends a conditional approval of the Final Plat.

FINAL PLAT CONDITIONS OF APPROVAL:
1) City of Tucson Development Standards (DS) Section No.2-03.3.2.D: Street abandonment for Britannia Way right-of-way must be done prior to, or concurrently with, the platting final plat.
2) DS Sec.10-02.14.3.2: Revise CC&R's to add basin maintenance information per this section. Otherwise, this section may be added as a general note to the Final Plat.
3) DS Sec.2-03.2.4.L.1: Show areas of detention/retention including 100-year ponding limits with water surface elevations. On sheet 2, the revised delineations for the ponding limits at the basin adjacent to lot 322 appear to be missing.
4) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. It was stated in the response letter that these are forthcoming. Address the following for other portions of the assurance package:
a) Revise any sheets of the assurance paperwork to reflect any change in descriptions of the common areas.
b) Provide AMENDMENT TO TRUST / THIRD PARTY TRUST.
c) Provide AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST.
d) Provide copy of sample Warranty Deed.

For resubmittal, please submit the remaining assurance package items, revised, signed copy of the CC&R's, and the revised Final Plat mylar. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department