Plan Number: S02-017
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - FINAL PLAT REVIEW

Plan Number - S02-017
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/21/2004 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: TIERRA VISTA
PH II, Lots 14-19, 54-98, 286-298, 310-338 & 345-371
S02-017

Tucson Electric Power Company (TEP) has reviewed the final plat for phase II dated April 15, 2004. TEP is unable to approve the plat at this time.

In order for TEP to approve the final plat for phase II, the following is required:

Remove the second word FOR from the 3rd paragraph of the dedication to read as follows: .........EASEMENTS AS SHOWN HEREON FOR THE PURPOSES OF ACCESS, INSTALLATION AND MAINTENANCE OF PUBLIC.............

Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8479
Pager: (520) 218-6565
Fax: (520) 917-8400
04/21/2004 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S02-017 TIERRA VISTA/REVISED FINAL PLAT
DATE: April 19, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:


Change CA “A” to CA “C” on pg. 1.

Change “Sunrise View Way” to Sun View Way on pg. 3.


















jg
04/30/2004 DAN CASTRO ZONING REVIEW Approved
05/03/2004 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

RICK LYONS
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Ed Abrigo, Mapping Supervisor
Pima County Assessor's Office
Mapping Department

DATE: March 29, 2004


RE: Assessor's Review and Comments Regarding Final Plat
S02-017 Tierra Vista


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_______ Plat does not meet Assessor's Office requirements.


COMMENTS: Thank you for your submittal.

NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.







Susan C. King
05/07/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Denied SUBJECT: 2nd submittal Engineering review of the Tierra Vista Phase 2 Final Plat
ACTIVITY #: S02-017
REVIEWER: Elizabeth Eberbach
LOCATION: T15S, R14E, Section 9

SUMMARY: The revised Final Plat, Drainage Reports, portions of the assurance paperwork, temporary easement paperwork, revised CC&R's, and location map were received by Engineering on April 15, 2004. Development Services Department Engineering Division has done a review of the received items and does not recommend approval of the Final Plat at this time.

FINAL PLAT COMMENTS:
1) City of Tucson Development Standards (DS) Section No. 2-03.6.4.K: The docket and page information for the temporary access easements must be in the mylar prior to approval of the Final Plat.
2) Per DS Sec.2-03.3.2.D, applications for street abandonment are supposed to be made to the Real Estate Division of the Department of Transportation, as I referred to in my email dated 19APR04. Label abandonment for Britannia Way right-of-way per plat on sheet 3.
3) DS Sec.2-03.6.6.A: Revise CC&R's. See DS Sec.10-02.14.3.2, and add basin maintenance information per this section.
4) Your response letter requested clarification of how basins are delineated on the Final Plat. In the Development Standard Section 2-03.6.4.I it asks to "show detention/retention areas in a surveyable and readily retraceable manner", whereas section 2-03.2.4.L.1 asks to "show areas of detention/retention including 100-year ponding limits with water surface elevations". The revised descriptions and delineations for the ponding limits and basin appear to be corrected in this submittal, other than a question regarding the linetype in the legend for ponding limits.
5) DS Sec.2-03.6.1.L: The 100-year ponding limits linetype in legend does not match linetype on planview on sheet 3; correct discrepancy.
6) DS Sec.2-03.8.1.B: There still needs to be clarification for the Tucson International Gateway lots south of Phase II. Label the parcel south of Phase II (Future Phase III" is insufficient).
7) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. It was stated in the response letter that these are forthcoming. Address the following for other portions of the assurance package:
a) Revise any sheets of the assurance paperwork to reflect any change in descriptions of the common areas.
b) Provide AMENDMENT TO TRUST / THIRD PARTY TRUST.
c) Provide AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST.
d) Provide copy of sample Warranty Deed.

For resubmittal, please submit the remaining assurance package items, revised, signed copy of the CC&R's, and the revised Final Plat. For further clarification, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department