Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - FINAL PLAT REVIEW
Plan Number - S02-017
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/21/2004 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: TIERRA VISTA PH II, Lots 14-19, 54-98, 286-298, 310-338 & 345-371 S02-017 Tucson Electric Power Company (TEP) has reviewed the final plat for phase II dated April 15, 2004. TEP is unable to approve the plat at this time. In order for TEP to approve the final plat for phase II, the following is required: Remove the second word FOR from the 3rd paragraph of the dedication to read as follows: .........EASEMENTS AS SHOWN HEREON FOR THE PURPOSES OF ACCESS, INSTALLATION AND MAINTENANCE OF PUBLIC............. Liza Castillo Land Management Tucson Electric Power Company lcastillo@tep.com Office: (520) 917-8479 Pager: (520) 218-6565 Fax: (520) 917-8400 |
| 04/21/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S02-017 TIERRA VISTA/REVISED FINAL PLAT DATE: April 19, 2004 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Change CA “A” to CA “C” on pg. 1. Change “Sunrise View Way” to Sun View Way on pg. 3. jg |
| 04/30/2004 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 05/03/2004 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 RICK LYONS ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ed Abrigo, Mapping Supervisor Pima County Assessor's Office Mapping Department DATE: March 29, 2004 RE: Assessor's Review and Comments Regarding Final Plat S02-017 Tierra Vista * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: Thank you for your submittal. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. Susan C. King |
| 05/07/2004 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | SUBJECT: 2nd submittal Engineering review of the Tierra Vista Phase 2 Final Plat ACTIVITY #: S02-017 REVIEWER: Elizabeth Eberbach LOCATION: T15S, R14E, Section 9 SUMMARY: The revised Final Plat, Drainage Reports, portions of the assurance paperwork, temporary easement paperwork, revised CC&R's, and location map were received by Engineering on April 15, 2004. Development Services Department Engineering Division has done a review of the received items and does not recommend approval of the Final Plat at this time. FINAL PLAT COMMENTS: 1) City of Tucson Development Standards (DS) Section No. 2-03.6.4.K: The docket and page information for the temporary access easements must be in the mylar prior to approval of the Final Plat. 2) Per DS Sec.2-03.3.2.D, applications for street abandonment are supposed to be made to the Real Estate Division of the Department of Transportation, as I referred to in my email dated 19APR04. Label abandonment for Britannia Way right-of-way per plat on sheet 3. 3) DS Sec.2-03.6.6.A: Revise CC&R's. See DS Sec.10-02.14.3.2, and add basin maintenance information per this section. 4) Your response letter requested clarification of how basins are delineated on the Final Plat. In the Development Standard Section 2-03.6.4.I it asks to "show detention/retention areas in a surveyable and readily retraceable manner", whereas section 2-03.2.4.L.1 asks to "show areas of detention/retention including 100-year ponding limits with water surface elevations". The revised descriptions and delineations for the ponding limits and basin appear to be corrected in this submittal, other than a question regarding the linetype in the legend for ponding limits. 5) DS Sec.2-03.6.1.L: The 100-year ponding limits linetype in legend does not match linetype on planview on sheet 3; correct discrepancy. 6) DS Sec.2-03.8.1.B: There still needs to be clarification for the Tucson International Gateway lots south of Phase II. Label the parcel south of Phase II (Future Phase III" is insufficient). 7) DS Sec.2-03.7.1.G: The final plat cannot be scheduled for Mayor and Council consideration until the financial assurances are approved. It was stated in the response letter that these are forthcoming. Address the following for other portions of the assurance package: a) Revise any sheets of the assurance paperwork to reflect any change in descriptions of the common areas. b) Provide AMENDMENT TO TRUST / THIRD PARTY TRUST. c) Provide AGREEMENT TO CONSTRUCT SUBDIVISION IMPROVEMENTS / THIRD PARTY TRUST. d) Provide copy of sample Warranty Deed. For resubmittal, please submit the remaining assurance package items, revised, signed copy of the CC&R's, and the revised Final Plat. For further clarification, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |