Plan Review Detail
Review Status: Completed
Review Details: REVISION - TENTATIVE PLAT REVIEW
Plan Number - S01-010
Review Name: REVISION - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/16/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | 1) A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from driving onto unimproved portions of the site. per DS 3-05.2.3.C. Revise the plans as necessary to provide barriers at unpaved areas. 2) A street landscape border per LUC 3.7.2.4 is required along Price Street. 3) Revise the plans to allow water harvesting in the hydro-seed areas by depressing the grades if possible. 4) Revise the plans to provide canopy trees in compliance with LUC 3.7.2.3.A.1.a for the parking spaces northeast of the future administration building and east of the maintenance building. |
| 11/28/2007 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: S01-010 COT Suntran Bus Storage Tentative Plat (Revision) TRANSMITTAL DATE: November 28, 2007 DUE DATE: December 03, 2007 COMMENTS: Conditionally approved 1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is May 28, 2008. On city projects ADA requirements are to be reviewed and approved by the Office of Equal Opportunity Program, Martin Dupont or third party review agency, which has been selected by the O.E.O.P office. While it is not clear whether the O.E.O.P office or approved third party review agency has reviewed the S01-010 plan it would be a good idea to contact Martin with any follow up regarding the following comments. His office number is 791-4593. The following zoning ADA comments must be addressed and changes made to the plan prior to submittal of the Mylar for stamps and signatures. 2. Label the maximum slope allowed for handicapped parking spaces and access aisle that serves the parking spaces. The maximum slope allowed per ANSI section 503.4 is 1:48 (2%). Label the slope on the handicapped parking space detail and access aisle. 3. Truncated domes are required at all access ramps and at areas where the sidewalk is flush and transitions from the sidewalk to the vehicular use areas. This includes at the H.C. access aisle that transitions from the sidewalk onto the aisle. Draw and label the required truncated domes on the plan and detail drawings on the plan sheet C-3 that provides the required information. If you have any questions about this transmittal, please call David Rivera, (520) 837-4957. DGR C:\planning\cdrc\tentativeplat\S01010tprca.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan/ tentative plat for Mylar review. |
| 11/29/2007 | JIM EGAN | COT NON-DSD | FIRE | Approved | |
| 12/03/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 3, 2007 John C. McGann G.L.H.N. Architects and Engineers, Inc 2939 East Broadway Blvd. Tucson, Arizona 85716 Subject: S01-010 Suntran Bus Storage Revised Development Plan/Tentative Plat Dear John: The above referenced development plan/tentative plat has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per on-line, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan/Tentative Plat, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan/Tentative Plat. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. Please note that the final plat must be approved by Mayor and Council and recorded within one year of date of approval of the tentative plat per LUC 4.1.7.3. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. WRITTEN APPROVAL FROM MARTIN DUPONT (PER ZONING COMMENTS) MUST BE SUBMITTED WITH THE MYLAR SET. Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 795-1822 |