Plan Review Detail
Review Status: Completed
Review Details: REVISION - TENTATIVE PLAT REVIEW
Plan Number - S01-005
Review Name: REVISION - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/02/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/13/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | The revised landscape plans do not correspond with previously approved version. A number of revisions are required in order for the plan to meet the minimum code requirements and conditions of rezoning. 1) Revise the landscape plans to provide the minimum requirements as indicated in the calculations on Sheet LX-1. 2) Revise the landscape plan to provide the required 30" screen along the south boundary adjacent to the p.a.a.l. C9-00-18 3) Revise the landscape plan to provide the required 30" screen along the Wilmot Road frontage. 4) Revise the landscape plan to show the required 5' masonry screen walls along the north and west property boundaries. LUC 3.7.2-I 5) Revise the landscape plan to include the required screening for the refuse storage areas. LUC Table 3.7.2-I 6) Revise the landscape plan to provide at least one tree for every 33 feet in the landscape borders. LUC Table 3.7.2-I 7) The landscape plan is required to meet the minimum requirements for preservation per LUC 3.8 and to provide the minimum number of mitigation plants. DS 2-15.3.4.B 8) Revise the landscape plan to provide 50% vegetative coverage for the Wilmot Road street landscape border. The plants used for screening are not calculated for coverage. DS 2-06.3.7 |
| 03/27/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES March 27, 2006 Marty Magelli Baker & Associates Engineering, Inc. 1636 North Swan Road Suite 200 Tucson, AZ 85712 Subject: S01-005 Wilmot Office Park Revised Tentative Plat Dear Marty: Your submittal of February 1, 2006, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have received and addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Tentative Plat (Landscape, DSD) 2 Copies Revised Landscaping Plan (Landscape, DSD) Should you have any questions, please call me at 791-5608. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 318-1930 |