Permit Number: DS20-12
Parcel: 117072260

Address:
741 S 6TH AV

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS20-12
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2020 SBEASLE1 START PLANS SUBMITTED Completed
08/11/2020 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: DS20-12
Baffert at Five Points
DP19-0220

TRANSMITTAL DATE: May 16, 2019

DUE DATE: August 11, 2020

COMMENTS:


01. TSMR - 10-01.4.1.A.1.a - Approved

02. TSMR - 7-04.4.1.D - Approved Conditionally This approval does not eliminate the required connection only routes the connection to the sidewalk along 18th Street which provided the connection to Arizona Av.

03. TSMR - 8-01.9.0 & Figure 3A - Approval

04. TSMR - 8-01.5.3.H - Approval

Provide the TSMR case number, DS20-12, adjacent to the title block on all sheets. Also provide a general note stating the TSMR Case number, date of approval, what was modified and if applicable any conditions of approval.

If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956
08/12/2020 SBEASLE1 ENV SVCS REVIEW Reqs Change ES response to TSMR , The Baffert, DS20-12.
8-01.9.0 figure 3A (enclosure) and 8-01.5.3.H (enclosure).
Approved conditionally, must depict complete turning radii for ingress (from 6th Ave immediate travel lane onto one way drive) and egress ( from driveway onto Arizona Ave,) and demonstrate 3 ft clear from any objects/structures, within resubmittal. TSM 8-01.5.3.E

Recommend rolled curbs at ingress and egress where service vehicle maneuvering may be restricted.

Feel free to contact me if you have any questions.
Sincerely,
Andy Vera
City of Tucson - Environmental Services
Accounts Representative Supervisor
(520) 837-3798
Andy.Vera@TucsonAz.gov
08/17/2020 ZELIN CANCHOLA TRAFFIC TRAFFIC Approved
08/17/2020 LOREN MAKUS ENGINEERING REVIEW Approved
08/18/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change DATE: Aug. 18, 2020

TSMR RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: Resubmittal of documents

DESCRIPTION: Baffert, TSMR: 10-01.4.1.A.1.a (sidewalk),
7-04.4.1.D (pedestrian), 8-01.9.0 figure 3A (enclosure),
and 8-01.5.3.H (enclosure).

PERMIT/ACTIVITY: DS20-12
FEE BALANCE: $0 (zero) Thank you for the payment.

SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews - click on Review Details
- Documents - click on View to the right of each document

YOUR NEXT STEP:
Submit updated documents to the Filedrop:
https://www.tucsonaz.gov/file-upload-pdsd

FOR FASTER PROCESSING:
When on the Filedrop page, select the box
"Development Package or Land Division".

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov