Permit Number: DS18-14
Parcel: 11106157A

Address: Unknown

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS18-14
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2018 KELLY LEE START PLANS SUBMITTED Completed
06/25/2018 MARTIN BROWN FIRE REVIEW Approved
06/26/2018 ZELIN CANCHOLA TRAFFIC TRAFFIC Approved
06/29/2018 LOREN MAKUS ENGINEERING REVIEW Approved
07/02/2018 SSHIELD1 H/C SITE REVIEW Approved
07/02/2018 DAVID RIVERA ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Site Section Manager

PROJECT: DS18-14
Count of Monte Vista
DP18-0116

TRANSMITTAL DATE: July 2, 2018

DUE DATE: June 29, 2018

COMMENTS:

01. TSMR - 8-01.5.3.F - Approved

02. TSMR - 7-01.3.3/7-01.4.1.D - Approved

03. TSMR - 10-01.4.1 - Approved

04. TSMR - 10-01.9.0 - Approved

05. TSMR - 10-01.2.7 - Approved


If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956
07/20/2018 AHINES2 ENV SVCS REVIEW Approved I reviewed the proposed solid waste management plans for the Count of Monte Vista residential subdivision with Pat Tapia.

The applicant is asking for a Technical Standard Modification Request (TSMR) due to the approximate 128 foot back-up distance from the enclosure proposed to be located at the east end of the east - west road in the residential subdivision. The approximate 128 foot back-up distance is greater than the desired maximum back-up distance for refuse vehicles of 80 feet. In addition to this back-up distance, the refuse vehicle must back onto the north - south road adjacent to the parking spaces at the intersection of the two roads.

We evaluated the possibility relocating the enclosure within the residential subdivision. One alternative we looked at was to locate the enclosure at the south end of the north - south road. There did not appear to be enough room given the current layout of the residential lots, roads and parking spaces to position the enclosure at this location. An enclosure at this location may interfere with traffic and access for Lot No. 9. Another alternative is to locate the enclosure in the parking area to the north of Lots 18 through 22. However, this alternative would require the elimination of several parking spaces which probably would not be desired by the developer.

As there does not appear to be any feasible alternatives for the location of the enclosure, Environmental & General Services Department approves the TSMR for the Count of Monte Vista residential subdivision.

Please contact me if there are any questions concerning this review.

Tom Ryan, P. E.
City of Tucson - Environmental & General Services Department
07/31/2018 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond The TSMR was approved on 7/31/2018. Add the case number, DS18-14, in the lower right hand corner next to the title block on each sheet of the development package. Add a general note that includes the case number, type of request, date of approval, and modifications granted to the development package.

The TSMR application and reference sheet went to records. There is nothing for the applicant to pick up.