Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS17-22
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/17/2017 QJONES1 START PLANS SUBMITTED Completed
11/20/2017 SSHIELD1 H/C SITE REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: DS17-22
VCA Valley Animal Hospital
DP17-0218

TRANSMITTAL DATE: November 20, 2017

DUE DATE: November 24, 2017

COMMENTS:

01. TSMR - 7-01.4.1.B - Approved with conditions - Provide an accessible route between the "PET RESORT" and the "ANIMAL HOSPITAL (EXISTING) that meets the requirements of 2012 IBC Chapter 11 and the ICC A117.1-2009.

02. TSMR - 10-01.3.2.C - Approved


If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956
11/20/2017 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: DS17-22
VCA Valley Animal Hospital
DP17-0218

TRANSMITTAL DATE: November 20, 2017

DUE DATE: November 24, 2017

COMMENTS:

01. TSMR - 7-01.4.1.B - Approved with conditions - Provide an accessible route between the "PET RESORT" and the "ANIMAL HOSPITAL (EXISTING) that meets the requirements of 2012 IBC Chapter 11 and the ICC A117.1-2009.

02. TSMR - 10-01.3.2.C - Approved


If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956
11/20/2017 ZELIN CANCHOLA TRAFFIC TRAFFIC Approved
11/21/2017 MARTIN BROWN FIRE REVIEW Approved
11/28/2017 ALEXANDRA HINES ZONING-DECISION LETTER WRITE DECISION LETTER Approved TSMR approved on 11/28/2017. Add the case number, DS17-22, in the lower right hand corner next to the title block on each sheet of the development package. Add a general note that includes the case number, type of request, date of approval, modifications granted, and zoning condition imposed to the development package.
11/28/2017 AHINES2 ENV SVCS REVIEW Approved For the curb radius for the Valley Animal Hospital site, I reviewed the refuse truck maneuverability with Andy Vera of our Department. I also reviewed the curb radius with the Figures in Section 8 of the Technical Standards Manual. Based on these reviews, the 25 foot curb radius would allow access for a City of Tucson refuse vehicle. Therefore, the proposed design is approved.

Let me know if any questions.

Tom Ryan, P. E.
City of Tucson - Environmental & General Services Department
11/28/2017 LOREN MAKUS ENGINEERING REVIEW Approved