Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS15-21
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/10/2015 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 09/10/2015 | BVIESTE1 | ENV SVCS | REVIEW | Passed | ESD Folder closed by CDRC Office because ESD has approved the tentative plat. |
| 09/15/2015 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: DS15-21 Casa Seton Tentative Plat DP15-0114 TRANSMITTAL DATE: September 15, 2015 DUE DATE: September 15, 2015 COMMENTS: 01. TSMR - 10-01.6.2.C.2 & Figure 23 - Approved 02. TSMR - 10-01.2.4.D.2 - Approved 03. TSMR - 10-01.2.1 - Approved 04. TSMR - 10-01.2.3 & Figure 1 - Approved 05. TSMR - 10-01.2.3 & Figure 1 - Approved If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956 |
| 09/15/2015 | SSHIELD1 | H/C SITE | REVIEW | Approved | See Zoning comments |
| 09/15/2015 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approv-Cond | DATE: September 15, 2015 TO: Bill Carroll, P.E., Engineering and Environmental Consultants, Inc. SUBJECT: TSMR for Casa Seton Tentative Plat Engineering Review submittal PROJECT: Casa Seton LOCATION: 1777 N POTTER P, 123-01-017F, T14S R14E Sec5, Ward 6 IMPACT FEE AREA: Central FEMA PANEL: 2277L, Zone X-Unshaded WATERSHED: Flowing Wells Wash Watershed (a non-designated basin management area) REVIEWER: Elizabeth Leibold P.E. ACTIVITY NUMBER: DS15-21 SUMMARY: The Technical Standard Modification Request for the following modifications was reviewed by PDSD Engineering. Development Services Department Engineering Division recommends approval of (1) TSMR of Tech Man Secs.10-01.6.2.C.2 & Figure 23, (2) TSMR of Tech Man Sec.10-01.2.4.D.2, (3) TSMR of Tech Man Sec.10-01.2.1, (4) TSMR of Tech Man Sec.10-01.2.3 & Figure 1, and (5) TSMR of Tech Man Sec.10-01.2.3 & Figure 1, with the following conditions: 1) Header curbs conform to PC/COT Standard Detail 213. 2) South pedestrian refuge area shall be composed of compacted fill with one of the surface options in Technical Manual Section 7-01.4.3.C.1-5 only. If you have questions, call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Dept |
| 09/15/2015 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 09/17/2015 | BVIESTE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | Approved 9/17/2015 Add Case # to each sheet of DP in the lower right-hand corner. Add a General Note to the DP that states Date of Approval, Case Number, Modifications Granted, and Conditions Imposed. See Engineering Conditions. |