Permit Number: DS15-21
Parcel: 12301017F

Address:
1777 N POTTER PL

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS15-21
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/10/2015 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/10/2015 BVIESTE1 ENV SVCS REVIEW Passed ESD Folder closed by CDRC Office because ESD has approved the tentative plat.
09/15/2015 DAVID RIVERA ZONING REVIEW Approved CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: DS15-21
Casa Seton Tentative Plat
DP15-0114

TRANSMITTAL DATE: September 15, 2015

DUE DATE: September 15, 2015

COMMENTS:

01. TSMR - 10-01.6.2.C.2 & Figure 23 - Approved

02. TSMR - 10-01.2.4.D.2 - Approved

03. TSMR - 10-01.2.1 - Approved

04. TSMR - 10-01.2.3 & Figure 1 - Approved

05. TSMR - 10-01.2.3 & Figure 1 - Approved


If you have any questions about this transmittal, please call Steve Shields, (520) 837-4956
09/15/2015 SSHIELD1 H/C SITE REVIEW Approved See Zoning comments
09/15/2015 ELIZABETH LEIBOLD ENGINEERING REVIEW Approv-Cond DATE: September 15, 2015
TO: Bill Carroll, P.E., Engineering and Environmental Consultants, Inc.
SUBJECT: TSMR for Casa Seton Tentative Plat Engineering Review submittal
PROJECT: Casa Seton
LOCATION: 1777 N POTTER P, 123-01-017F, T14S R14E Sec5, Ward 6
IMPACT FEE AREA: Central
FEMA PANEL: 2277L, Zone X-Unshaded
WATERSHED: Flowing Wells Wash Watershed (a non-designated basin management area)
REVIEWER: Elizabeth Leibold P.E.
ACTIVITY NUMBER: DS15-21

SUMMARY: The Technical Standard Modification Request for the following modifications was reviewed by PDSD Engineering. Development Services Department Engineering Division recommends approval of (1) TSMR of Tech Man Secs.10-01.6.2.C.2 & Figure 23, (2) TSMR of Tech Man Sec.10-01.2.4.D.2, (3) TSMR of Tech Man Sec.10-01.2.1, (4) TSMR of Tech Man Sec.10-01.2.3 & Figure 1, and (5) TSMR of Tech Man Sec.10-01.2.3 & Figure 1, with the following conditions:
1) Header curbs conform to PC/COT Standard Detail 213.
2) South pedestrian refuge area shall be composed of compacted fill with one of the surface options in Technical Manual Section 7-01.4.3.C.1-5 only.
If you have questions, call me at 837-4934.
Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Dept
09/15/2015 KEN BROUILLETTE FIRE REVIEW Approved
09/17/2015 BVIESTE1 ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond Approved 9/17/2015

Add Case # to each sheet of DP in the lower right-hand corner.

Add a General Note to the DP that states Date of Approval, Case Number, Modifications Granted, and Conditions Imposed.

See Engineering Conditions.