Permit Number: DS15-13
Parcel: 13401034E

Address:
489 S GOLLOB RD

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS15-13
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/12/2015 CPIERCE1 START PLANS SUBMITTED Completed
05/12/2015 ZELIN CANCHOLA TRAFFIC TRAFFIC Approved
05/13/2015 PGEHLEN1 ENV SVCS REVIEW Reqs Change Hello Patricia,

Please see comments:
---------------------------------------------------------------------------
1. General note 9 should read/include as follows:
Refuse and Recycle collection will be performed by residential curbside service method within private street. Curbside collection service will be provided within private street as long as street is maintained by property owner/s so provides safe access for service vehicle. Unmaintained conditions may require APC's to be rolled out onto Gollob Rd.

2. Clarify whether this will be a designated private street or just a long private driveway to lots 1 & 2. Applicable charges are subject to long driveway conditions as per Tucson Code Chapter 15.

3. Turnaround is adequate for service access and maneuverability.

--------------------------------------------------------------------------

Thanks,


Andy Vera
City of Tucson Environmental Services
Accounts Representative Supervisor
Office (520) 837-3798
Fax (520) 791-4156
e-mail: Andy.Vera@tucsonaz.gov
05/15/2015 RONALD BROWN H/C SITE REVIEW Approved
05/18/2015 ELIZABETH LEIBOLD ENGINEERING REVIEW Reqs Change Tech Man Sec.10-01.3.1.A.3 does allow for double shot sealcoat of emulsified asphalt and stone chips. However, Tech Man Sec.10-01.3.1.A states that all pavement sections will be designed in accordance with ambient soil conditions and projected use, using a method acceptable to the City
Engineer, and 10-01.4.4.E.1 states that paved All Weather Access is required for access to each lot. Also, 4-04.11.6 discusses 2-ft min header along paved roads in floodplain.
Therefore, in the areas of floodplain, the PDSD Engineering still will need minimum 2-in asphalt over 4-in aggregate base with 2-ft header curb. Remaining areas of the private street will need the double-shot chip seal and some form of curb to provide separator for sidewalk. Sidewalk slopes shall meet any accessibility requirements.
05/18/2015 KEN BROUILLETTE FIRE REVIEW Approved -
05/18/2015 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: DS15-13
489 S Gollob Road
TSMR - 10-01.2.3.A.1 and 10-01.3.2.A

TRANSMITTAL DATE: May 18, 2015

DUE DATE: May 19, 2015

COMMENTS: Denied due to zoning denial of 10-01.3.2.A

01. TSMR for 10-01.2.3.A.1 - Approved contingent upon approval by PDSD Engineering, Environmental Services and Fire.

02. 10-01.3.2.A - Denied, While it is acknowledged that the street is to be inverted to carry the water the proposed cross section does not provide for physical separation between the travel lanes and the pedestrian refuge area.

Curbs must be provided and the pedestrian refuge area must be graded to meet the minimum slope requirements. The proposed 3 to 1 slopes are not acceptable for an accessible pedestrian refuge area.

03. CC&R's that provide for the maintenance of the private road and pedestrian refuge areas are required and shall be recorded with the subdivision plat after approval by Mayor and Council.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
05/19/2015 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change Please address comments and resubmit.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/10/2015 FERNE RODRIGUEZ OUT TO CUSTOMER Completed