Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS14-26
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/22/2014 | SPOWELL1 | START | PLANS SUBMITTED | Completed | |
| 09/23/2014 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: September 24, 2014 SUBJECT: TSMR Request- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 151 E Broadway Blvd REVIEWERS: Jason Green, CFM ACTIVITY: DS14-26 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Technical Standard Modification Request (TSMR). Engineering Division does not recommend approval of the TSMR at this time. TSMR PLAN: 1. Revise the TSMR plan package to include the SVT's at all required locations. The 15-foot stem side is supported however the SVT's need to be added to the intersection of the access lane and Arizona Avenue and a pedestrian SVT needs to be added to the near side of the intersection of Arizona Avenue and Broadway Blvd. 2. Revise the TSMR plan package to label and dimension the proposed curb returns along 5th Avenue and the intersection of Arizona Avenue and Broadway Blvd. The reduction of the radii is acceptable for PDSD review however final TDOT approval will be required and the plan must be revised to reflect what is proposed. 3. Revise the TSMR plan package and the TSMR Application to clearly state and show what is proposed for the pedestrian access. Pedestrian access is required along Arizona Avenue and the plan must reflect pedestrian access from the building to the required sidewalk within Arizona Avenue. Pedestrian access must also be provided adjacent and parallel to any access lane on the side where the building is located. PDSD will support the use of 5th Avenue as the pedestrian connectivity from the proposed building to the existing buildings onsite but access to the adjacent roadways is still required. 4. Revise the application to accurately reflect what is being modified and clearly show these modifications in plan view. A TSMR can only be used to modify a Technical Standard not to eliminate the standard. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 09/24/2014 | RONALD BROWN | H/C SITE | REVIEW | Reqs Change | 1. Provide an accessible route connection from the hotel to the adjacent buildings north of the hotel within the bounadries of the property. a. Or obtain a TSMR for the use of the crossing shown in the 5St right of way. 2. Accessible Drop Off Zone a. Provide dimensions b. Show directional slope arrows and slope percentages. c. Confer with Zoning for separation of pedestrian way and vehicle way. 3. Trash Enclosure Detail a. For Both Ramps: Provide dimensions, slopes, grade elevations, handrails on both sides, directional arrows and slope percentages and landings. b. For the stair: provide dimensions, handrails on both sides, landings, grade difference, riser and tread dimensions. END OF REVIEW |
| 09/26/2014 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: DS14-26 AC Hotel Broadway TSMR 10-01.5.2A, 10-01.3.2.C, 7-01.4.1.A TRANSMITTAL DATE: September 26, 2014 DUE DATE: September 26, 2014 COMMENTS: 01. TSMR 10-01.5.2.A - conditionally approved subject to approval by TDOT and PDSD Engineering. 02. TSMR 10-01.3.2.C - conditionally approved subject to approval by TDOT and PDSD Engineering. 03. TSMR 7-01.4.1.A - Zoning approves the request to allow the public street sidewalk to be approved as the pedestrian access to the building. 04. List the TSMR case number as a general note and list in the the lower right corner of the development plan sheets. The genral note shall include the TSMR standards sections requested, date of approval along with any conditions of approval. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 09/30/2014 | ZELIN CANCHOLA | TRAFFIC | TRAFFIC | Approved | |
| 10/01/2014 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Pending additional information |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/01/2014 | PGEHLEN1 | APPROVAL SHELF | Completed |
| 10/01/2014 | PGEHLEN1 | OUT TO CUSTOMER | Completed |
| 10/01/2014 | PGEHLEN1 | REJECT SHELF | Completed |