Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DS14-24
Parcel: 99999999A

Address:
6105 E PIMA ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS14-24
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2014 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/10/2014 RONALD BROWN H/C SITE REVIEW Approved
09/10/2014 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: DS14-24
6105 E Pima Street
Alamo Crossing - DSMR

TRANSMITTAL DATE: September 10, 2014

DUE DATE: September 16, 2014

COMMENTS:

01. Zoning conditionally approves the TSMR's contingent upon PDSD Engineering, E.S. and TDOT approval. If any of the three noted sections deny the requested TSMR's zoning approval is considered denied.

While zoning sees the requested TSMR's as reasonable equests due to the nature and type of development zoning also respects the standards and will defer to the departments that are affected by the modifications.

02. If the TSMR's are approved, ensure that the information related to the application case number, TSMR's requested, and date of approval are listed as a general note on the tentative plat. The case number shall be listed in the lower right corner of all TP sheets.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
09/15/2014 PGEHLEN1 ENV SVCS REVIEW Approv-Cond The TSMR has been reviewed on behalf of Environmental Services and all requests are approved with the following considerations:

Standard Number 10-01.9.0 Figure 1. The sidewalk is allowed to be reduced to 4 ft. from 5 ft. only if the distance between the sidewalk and the back of curb is kept at a minimum of 2.5 ft. as shown on the plans.

Standard Number 10-01.3.2.C and Figure 6. The 18 ft. radius is allowed on the west side of Placita Tejano but not on the east side. The east side must remain a 25ft. radius as shown on the plans.

If there are any questions, I can be reached at kperry@perryengineering.net
09/16/2014 KEN BROUILLETTE FIRE REVIEW Denied Per Appendix D (table D103.4) of the 2012 International Fire Code, the required width of the road is 26'.
09/17/2014 JOSE ORTIZ TRAFFIC TRAFFIC Approved
09/17/2014 JASON GREEN ENGINEERING REVIEW Approved No comments, defer to TDOT.
09/18/2014 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change Pending discussion with Developer.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/02/2014 PGEHLEN1 APPROVAL SHELF Completed
10/02/2014 PGEHLEN1 OUT TO CUSTOMER Completed
10/02/2014 PGEHLEN1 REJECT SHELF Completed