Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS13-04
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/13/2013 | CPIERCE1 | START | PLANS SUBMITTED | Completed | |
| 03/13/2013 | RONALD BROWN | H/C SITE | REVIEW | Denied | Please include on the drawings, how the Inclusive Home Design Ordenance is complied with concerning Section1003.2, Accessible Entrance. |
| 03/14/2013 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Terry Stevens Lead Planner DSD Zoning Review Section PROJECT: TSMR-DS13-04 1665 N. Brown Av. Technical Standards Modification (TSMR) Request Transmittal date: 03/15/2013 COMMENTS: Denied 1. Zoning cannot approve this TSMR. A TSMR is for modifications only not deletion of a code requirement. In order to eliminate the sidewalks a Board of Adjustment Variance will be required. Contact Mark Castro @ 837-4979 for further information on the BOA. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961. |
| 03/18/2013 | ZELIN CANCHOLA | TRAFFIC | TRAFFIC | Denied | From TDOT Traffic Engineering Zelin Canchola RE DS13-04 Brown Sidewalks are not required for either of the existing roadways, Wrightstown Rd and Brown Ave, per DS Sec.3-01.3.3.a.7 and the definition of Established Area within Sec.6.2.5 of the Land Use Code. "DS Sec.3-01.3.3 Pedestrian Circulation Paths. A. Sidewalks are required as part of new development of all properties. All new subdivisions and applications for building permits shall provide five (5) foot wide sidewalks along the entire length of street frontage, whether public or private, of the property in question. The sidewalk requirements also apply to expansions in floor area, site area, or vehicular use area of twenty-five (25) percent or more. Sidewalks are not required in the following circumstances. 7. On streets in established areas without existing curbs;" |
| 03/18/2013 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: March 18, 2013 SUBJECT: The Hacienda @ Wrightstown DSMR Request- Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 1665 N Brown Ave, T14S R15E Sec3 Ward 2 REVIEWERS: Jason Green, CFM ACTIVITY: DS13-04 Engineering Section cannot support the request to eliminate the public sidewalk within the new public roadway of Ohana Place as required per DS Sec.3-01.3.3.A. Development Standards may not be eliminated through the DSMR process only modified while still meeting the intent of the standard that is to be modified. This DSMR request does not provide for an alternative location or method (paved pathway) for the required sidewalk within the right-of-way of the new public roadway. A variance with justification is required to eliminate the required sidewalk. Sidewalks are not required for either of the existing roadways, Wrightstown Rd and Brown Ave, per DS Sec.3-01.3.3.a.7 and the definition of Established Area within Sec.6.2.5 of the Land Use Code. "DS Sec.3-01.3.3 Pedestrian Circulation Paths. A. Sidewalks are required as part of new development of all properties. All new subdivisions and applications for building permits shall provide five (5) foot wide sidewalks along the entire length of street frontage, whether public or private, of the property in question. The sidewalk requirements also apply to expansions in floor area, site area, or vehicular use area of twenty-five (25) percent or more. Sidewalks are not required in the following circumstances. 7. On streets in established areas without existing curbs;" For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 03/20/2013 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | Resubmittal is required. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/17/2013 | PGEHLEN1 | REJECT SHELF | Completed |
| 03/19/2013 | PGEHLEN1 | APPROVAL SHELF | Completed |
| 03/19/2013 | PGEHLEN1 | OUT TO CUSTOMER | Completed |