Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DS12-02
Parcel: 12709011K

Review Status: Completed

Review Details: DEVELOPMENT STANDARDS REVIEW

Permit Number - DS12-02
Review Name: DEVELOPMENT STANDARDS REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/07/2012 JWILLIA4 START PLANS SUBMITTED Completed
02/07/2012 JOHN WILLIAMS ZONING HC REVIEW Approved Approved - Per Ron Brown
02/07/2012 ELEIBOL1 ENGINEERING REVIEW Approved Project: Broadway Place II Lighting Improvement - Engineering review
Location: 6145 E BROADWAY BL
Case Number: DS12-02

Summary: Engineering Division has reviewed the proposed PDMR to have lighting infrastructure no less than 14-ft 1-in above grade located on the highlighted area on the plan provided. Engineering accepts proposed height. The following Engineering comment is provided for PDMR DS12-02:

1) DS Sec.10-02.13.5.2.4: The project is located in SFHA Zone AH on FIRM 2301L, and requires floodproofing of associated wiring for the lighting system, elevated associated electrical utility box / equipment to at least one foot above the 100-year water-surface elevation, and if needed, anchoring, as determined by a drainage statement as part of a Flood Plain Use permit that will be required for the associated permitting of this improvement.

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Dept
(520) 837-4934
02/07/2012 JWILLIA4 COT NON-DSD FIRE Approved Approved - No Comments Per Martin Brown
02/07/2012 JOHN WILLIAMS ZONING REVIEW Approv-Cond To CDRC Committee,
Project DS12-02 (PDMR)
Address: 6129 E Broadway Blvd.
Development Standard Modification Request (PDMR)

Based on the proposed location of the lighting fixtures, it seems unlikely that large vehicles would be accessing the area where the 15' height clearance would be a problem. The Zoning Review Section conditionally approves the PDMR if the Environmental Services and Fire Departments approve the PDMR.

Note: If either of the two departments deny the PDMR, the zoning conditional approval is void until any issues affecting the ES or FIRE Departments requirements are addressed.

David Rivera


David Rivera
Principal Planner
Development Services Department
(520) 837-4957
david.rivera@tucsonaz.gov
02/07/2012 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved Approved - No Comments Per Martin Brown
02/09/2012 JWILLIA4 ENV SVCS REVIEW Approved Date Case Number Project Address
February 9, 2012 DS12-02 Paradise Bakery & Cafe
BROADWAY PLACE II
6129 E. Broadway Boulevard

Comments:
The DSMR submitted for Case No.DS12-02, for the Paradise Bakery & Cafe Modification. Is acceptable to Environmental Services for solid waste and recycle materials disposal and is hereby APPROVED.
.


Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
02/16/2012 JOSE ORTIZ COT NON-DSD TRAFFIC Approved Approved - No Comments Per Martin Brown
02/16/2012 JWILLIA4 ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES




02/16/2012


Lisa Bowers
Metro TED
2940 N. Swan Road # 212
Tucson, Arizona 85712


Re: PDMR DS12-02 6129 E. Broadway Blvd. “Broadway Place II”


Request: DS 3.3.6.5.B - To reduce the minimum height clearance along access lanes and PAALS on the west side from 15’ to 14’-1”.


The Development Standard Modification Request(s) (DSMR) for DS 2-17.3 .1 listed above has been approved with the following conditions.



1. DS Sec.10-02.13.5.2.4: The project is located in SFHA Zone AH on FIRM 2301L, and
requires flood proofing of associated wiring for the lighting system, elevated associated
electrical utility box / equipment to at least one foot above the 100-year water-surface
elevation, and if needed, anchoring, as determined by a drainage statement as part
of a Flood Plain Use permit that will be required for the associated permitting of
this improvement.



If you have any additional questions, please contact me at 837-4899.

Sincerely,





John Williams
Planning Technician
Planning & Development Services Department



XC: File
Records


Email: Lisa@metroted.com