Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS11-11
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2011 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/16/2011 | RONALD BROWN | H/C SITE | REVIEW | Approved | |
| 08/17/2011 | DAVE MANN | FIRE | REVIEW | Approved | |
| 08/19/2011 | FRODRIG2 | ENV SVCS | REVIEW | Approved | Date of Comments Case Number Project Address August 18, 2011 DS11-11 Quebedeaux BUCK-GMC Development Plan Comments: The DSMR submitted for Case No. DS11-11, for the Quedebeaux BUCK-GMC, located at 3566 E Speedway Boulevard. Is acceptable to Environmental Services for solid waste and recycle materials and is hereby APPROVED. . Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 08/22/2011 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | Approved no Traffic Engineering TDOT issues. Review conducted by Zelin Canchola |
| 08/23/2011 | JOHN BEALL | COMMUNITY PLANNING | REVIEW | Passed | |
| 08/23/2011 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-11-11 3566 E. Speedway Boulevard Quebedeaux Buick-GMC Development Standard Modification Request Transmittal date: August 23, 2011 COMMENTS: Approved with conditions 1. After discussing the DSMR request(s) with the Zoning Administrator (due to unusual circumstances) the following is approved and approved with conditions. DS 2-08.3.1 - pedestrian circulation and accessible circulation, and accessible route surface: All circulation as proposed on the DSMR plan sheet is acceptable to Zoning with the following conditions and changes. 1. The pedestrian surface in front and corners of Building Two must be concrete. 2. Barriers such as wheel stops or bollards at a minimum of 5 feet on center must be provided for the sidewalk in front of Building 2 and the path from Building One to Building Two except where the vehicle crossing occurs. The alternative is to provide raised concrete sidewalks at these locations. 2. DS 6-01.4.1.A - Zoning supports this DSMR request contingent upon Environmental Services supports and approves the request as well TDOT approval due to right of way concerns. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 08/24/2011 | MATT FLICK | ENGINEERING | REVIEW | Approved | Revise General Note #6 on the Development Plan to reflect the Development Standard Modification Request. List the case number, date of approval, what was approved, and conditions of approval, if applicable. |
| 08/25/2011 | JOHN WILLIAMS | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES July 7, 2011 Richard Cordova DOWL HKM 406 N. Church Ave. Tucson, Arizona 85701 Re: DSMR DS11-11 (3566 E. Speedway Blvd.) (D11-0013) Request: DS 2-08.3.1 – Modify the Development Standard to waive pedestrian circulation path requirements. DS 6-01.4.1.A – Modify the Development Standard to waive access and placement of trash containers. The Development Standard Modification Request (DSMR) for DS 2-05.2.4.K listed above has been APPROVED with the following conditions: 1. The pedestrian surface in front and corners of building (2) two must be concrete. 2. Barriers such as wheel stops or bollards at a minimum of (5) five feet on center must be provided for the sidewalk in front of building (2) two and the path from building (1) one to building two except where the vehicle crossing occurs. The alternative is to provide raised concrete sidewalks at these locations. The Development Standard Modification Request (DSMR) for DS 6-01.4.1.A listed above has been APPROVED with the following conditions: 1. N/A PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE DEVELOPMENT PACKAGE WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE DEVELOPMENT PACKAGE, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4893. Sincerely, John Williams Planning Technician Planning & Development Services Department Attachments: 1 XC: File Records Fax (520) 624-0324 Email: Erin@starconsultingaz.com |