Permit Number: DS11-07
Parcel: 11446227B

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS11-07
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2011 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/15/2011 MARTIN BROWN FIRE REVIEW Approved
06/16/2011 LEERAY HANLY H/C SITE REVIEW Approved
06/20/2011 JOSE ORTIZ TRAFFIC TRAFFIC Approved
06/21/2011 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-11-07
2495 N Desert Links Drive
D11-0003
Development Standard Modification Request

Transmittal date: June 21, 2011

COMMENTS: DS 2-08.5.1.C is not supported at this time,
DS 2-08.4.1 is supported based on staff discussion, DS 3-01.4.1.1.b is supported with conditions, DS 6-01.4.2 is supported with conditions, DS 10-01.11.2.2 is supported with conditions.


1. After discussion with Staff the following is not supported at this time and must be addressed based on the DS 2-08 pedestrian standards as listed in the development standards manual.

a. DS 2-08.4.1 (sidewalk Separation) - The sidewalk separation or striped sections within the vehicular use areas (between parking spaces) that have been identified on the DSMR plan sheets can be supported with the exception of three locations. The locations are noted as the striped area adjacent or next to lot 44, the striped space between lot 11 and lot 13, the striped area between lot 20 and lot 22. In the case of the area between lot 20 and 22 the sidewalk can be extended to connect the two sidewalks. These three areas must be constructed with concrete in order to connect to the concrete sidewalks.

b. DS 2-08.5.1.C (Sidewalk Composition) - This DSMR request cannot be supported. The proposal to have DG as a pedestrian access that will also be used as an accessible route cannot be supported. The proposed information related to the manner of application for the DG material has been reviewed and approved by the Engineering Administrator Jim Vogelsberg. Based on his review and determination of the proposed product and application this material is not considered to be of equal or same hardness or durability to be considered as a viable or alternative material. This DSMR request is denied.

2. DS 3-01.4.1.1.b - (Width of the sidewalk within the Tanque Verde Right of Way) Zoning will support the DSMR request contingent upon approval by the COT Transportation Department.

3. DS 6-01.4.2 - (Enclosure and Bin Construction) Zoning will support the DSMR request contingent upon approval by the Environmental Services Department.

4. DS 10-01.11.2.2 - (Threshold Retention) Zoning will support the DSMR request contingent upon approval by the PDSD Engineering / Floodplain Section.




If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
06/22/2011 JHERSHE1 COMMUNITY PLANNING REVIEW Approv-Cond PLANNING AND DEVELOPMENT SERVICES COMMENTS
COT CDRC, Community Planning Comments

DS11-07, 2495 N. Desert Links Drive, 1st Submittal
Comments due: 6/22/11

Items reviewed: DSMR request
D11-0012, Tanque Verde at Wrightstown
Development Package

Comment:

The DSMR requests are approved, contingent upon approvals from Planning and Development Services, Zoning Review Section; and the Environmental Services Department. No resubmittal is required to the Community Planning Section.

Joanne Hershenhorn, 6/22/11
837-6976, joanne.hershenhorn@tucsonaz.gov


F:\Shardir\UPDfiles\Development Review\CASE_REVIEW\DSMR\11-12\DS11-07_2495DesertLksDr.doc
06/23/2011 FRODRIG2 ENV SVCS REVIEW Approv-Cond Date Case Number Project Address
June 22, 2011 DS11-07 Tanque Verde At Wrightstown Casitas
2495 N. Desert Links Drive
Comments:
The DSMR submitted for Case No. DS11-07, Tanque Verde At Wrightstown Casitas Site Located at 2495 N. Desert Links Drive. Is here by APPROVED by Environmental Service, subject to the following conditions:

1. The Tentative Plat must include recycle containers and must be shown and labeled on the site
plan.

2. All containers will require masonry enclosures with gates, and a detailed of the enclosures must
be shown and dimensioned on the plans in accordance’s with the must current
Development Standard No. 6-01.0. .
.


Environmental Services Department
Development Plan Review
Reviewer: Tony Teran
Office Phone (520) 837-3706
E-mail: Tony.Teran @tucsonaz.gov
06/24/2011 JOHN WILLIAMS ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES


06/27/2011


Nick Westphal
DOWL HKM
166 W. Alameda St.
Tucson, Arizona 85701


Re: DSMR DS11-07; 2495 N. Desert Links Dr.; (D11-0012)



Request: DS 2-08.4.1 - Modify the development standard to waive sidewalk separation location requirements.

DS 2-08.5.1.C - Modify the development standard to allow for an alternative surface composition on sidewalks.

DS 3-01.4.1.A.1.b - Modify the development standard to waive sidewalk width requirements on existing sidewalks.

DS 6-01.4.2 - Modify the development standard on required Enclosure and Bin Construction.

DS 10-01.II.2.2 - Modify the development standard to eliminate Threshold Retention.


The Development Standard Modification Request (DSMR) for DS 2-08.4.1 listed above has been Approved with the following exceptions:

1. The following three locations are excluded from the DSMR Approval.
a. Striped area adjacent or next to lot 44.
b. Striped area between lot 11 and lot 13.
c. Striped area between lot 20 and lot 22.

The Development Standard Modification Request (DSMR) for DS 2-08.5.1.C listed above has been Denied.


The Development Standard Modification Request (DSMR) for DS 3-01.4.1.A.1.b listed above has been Approved with the following conditions:

1. None

The Development Standard Modification Request (DSMR) for DS 6-01.4.2 listed above has been Approved with the following conditions:

1. The plans must include recycle containers and must be shown and labeled on the site plan.
2. All containers will require masonry enclosures with gates, and a detail of the enclosures must be shown and dimensioned on the plans in accordance with development standard 6-01.0.

The Development Standard Modification Request (DSMR) for DS 10-01.II.2.2 listed above has been Approved with the following conditions:

1. None




PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE PLAN IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 837-4893.

Sincerely,






John Williams
Planning Technician
Planning & Development Services Department

Attachments: 1

XC: File
Records

Fax (520) 624-0384
07/20/2011 PAUL MACHADO ENGINEERING REVIEW Approved To: Patricia Gehlen DATE: June 22, 2011
CDRC Manager

Subject: 2495 N. Desert links Drive
DS11-07

Dev. Std. Mod. Request:

1. DS 2-08.4.1 (sidewalk Separation) - The sidewalk separation or striped sections within the vehicular use areas (between parking spaces) that have been identified on the DSMR plan sheets can be supported with the exception of three locations. The locations are noted as the striped area adjacent or next to lot 44, the striped space between lot 11 and lot 13, the striped area between lot 20 and lot 22. In the case of the area between lot 20 and 22 the sidewalk can be extended to connect the two sidewalks. These three areas must be constructed with concrete in order to connect to the concrete sidewalks.
2. DS 2-08.5.1.C (Sidewalk Composition) - The DSMR request is not supported per the Engineering Administrator Jim Vogelsberg and in consultation with the zoning administrator Craig Gross.
3. DS 3-01.4.1.1.b - (Width of the sidewalk within the Tanque Verde Right of Way) - The eng. div. has no objection to the DSMR request.
4. DS 6-01.4.2 - (Enclosure and Bin Construction) - The eng. div. has no objection to the DSMR request provided Environmental Services has no objections.
5. DS 10-01.11.2.2 - (Threshold Retention) - The eng. div. has no objection to the DSMR request.


If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson - Planning and Development Services Department
201 N. Stone Avenue
P.O. Box 27210