Permit Number: DS09-32
Parcel: 13101054A

Address:
4702 E 22ND ST

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS09-32
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/20/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/21/2009 JOSE ORTIZ TRAFFIC TRAFFIC Approved The 22nd Street driveway is adjacent to a bus lane therefore curb returns are not required.

The Swan Road driveway is a secondary access point therefore curb returns are not required.
10/22/2009 DAVE MANN FIRE REVIEW Approved
10/23/2009 MATT FLICK ENGINEERING REVIEW Approved No objection to approval of a DSMR to allow:

Striped pedestrian area adjacent to southern building (offsite).

Use of a driveway apron on the 22nd Street driveway.

Use of a driveway apron on the Swan Road driveway.
10/23/2009 RONALD BROWN ZONING HC REVIEW Approved
10/26/2009 DAVID RIVERA ZONING REVIEW Approved
10/27/2009 JOHN BEALL COMMUNITY PLANNING REVIEW Approved PLANNING & DEVELOPMENT SERVICES DEPARTMENT
(PLANNING COMMENTS)

Regarding

SUBJECT: Development Standard Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS09-32 4702 E 22nd Street 10/27/09

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
(XXXX) Other - Site Plan

CROSS REFERENCE:

AREA/NEIGHBORHOOD PLAN:

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY 10/27/09

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

(X) Proposal Not an Annexation or Rezoning
No objection - however the proposed five (5) foot striped area should be of a color and change in paving texture that creates a clear distinction between pedestrian refuge area and vehicular area.



REVIEWER: JB 791-4505 DATE: 10/27/09
10/28/2009 ANDY VERA ENV SVCS REVIEW Approved
10/30/2009 JOHN WILLIAMS ZONING-DECISION LETTER WRITE DECISION LETTER Approved COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES


October 30, 2009

David Garcia
Architectural Design Group
2510 E. Grant Road, #140
Tucson, Arizona 85711


Re: DSMR DS09-32 Capin Carwash 4702 E. 22nd Street (T09CM01970)

Request: DS 2-08.4.1 - Modify the Development Standards to allow a five (5) foot striped pedestrian refuge area (sidewalk) in lieu of the five (5) foot raised pedestrian refuge area (sidewalk)

DS 3-01.3.2.C - Modify the Development Standards to relieve the radius curb return requirements.


The Development Standard Modification Request(s) (DSMR's) for DS 2-08.4.1 and DS 3-01.3.2.C listed above have been approved with the following conditions:

1) The proposed five (5) foot striped area should be of a color and change in paving texture that creates a clear distinction between pedestrian refuge area and vehicular area.


PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 837-4919.