Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS09-21
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/21/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
| 07/21/2009 | MATT FLICK | ENGINEERING | REVIEW | Approved | DSD Engineering has no objection or adverse comment to the approval of a DSMR for the following development standards: DS 2-08.3.1: To allow the deletion of a pedestrian circulation/accessible route connecting the In-N-Out to the rest of the shopping center. DS 3-05.2.1.C.2.a: To allow the accessible route from Kolb Road to cross the drive-thru stacking lane. |
| 07/22/2009 | DAVID RIVERA | ZONING | REVIEW | Approved | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-09-21 9157 E Broadway Blvd. In and Out Burger Restaurant Development Standard Modification Request Transmittal date: July 22, 2009 COMMENTS: Approved 1. DSMR for DS section 3-05.2.1 Approved, the location proposed for the accessible path to the street is the safest and most logical location. See the ADA review comments related to the proposed ramps. 2. DSMR for DS section 2-08.3.1 Approved, The existing shopping center was not developed with onsite continuous pedestrian circulation from the main shopping center building to the three pads along the south west corner of the site. The proposed In and Out Burger restaurant will provide access to the street sidewalk which in turn will provide an accessible path to the rest of the shopping center via the Broadway and Kolb sidewalks. While the street sidewalks do not have a direct connection to the main shopping center it is not feasible to add sidewalks to make the connection without losing required parking spaces. The site has the number of required spaces but not excess spaces. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 07/24/2009 | JOHN BEALL | COMMUNITY PLANNING | REVIEW | Approved | PLANNING & DEVELOPMENT SERVICES DEPARTMENT (PLANNING COMMENTS) Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS09-21 7101 / 7157 E. Broadway Blvd. 7/24/09 ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (XXXX) Other - Site Plan CROSS REFERENCE: AREA/NEIGHBORHOOD PLAN: GATEWAY/SCENIC ROUTE: Gateway COMMENTS DUE BY 7/27/09 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: (X) Proposal Not an Annexation or Rezoning No objection - No Comment. REVIEWER: JB 791-4505 DATE: 7/24/09 |
| 07/27/2009 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 07/30/2009 | ANDY VERA | ENV SVCS | REVIEW | Approv-Cond | ES has no objections to this specific modification request. However, the solid waste references as shown do not meet the minimum requirements per DS 6-01.0. If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 07/31/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approved | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES July 31, 2009 Keith Gilbert In-N-Out Burger 13502 Hamburger Lane Baldwin Park, CA 91706 Re: DSMR 09-21 - 7101 and 7157 East Broadway Blvd. (T09CM00441) Request: DS 3-05.2.1.C.2.a - Modify Development Standards to allow pedestrian circulation path to cross a drive thru lane, DS 2-08.3.1 - Modify Development Standards to not require continuous pedestrian circulation throughout the site since it is an existing condition of the site. The Development Standard Modification Requests (DSMRs) listed above has been APPROVED by the CRDC committee with the following conditions: 1) modify the sidewalk ramp per on line comments from Zoning HC Site, 2) Solid Waste enclosure and dumpster must be revised to meet DS 6-01. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE SITE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE SITE PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (626) 813-8277 |
| 07/31/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approv-Cond | 1. The location of the marked crossing is approved provided that the East ramp configuration is modifed for a side walk ramp down to a landing and then turn left to the detectable warning and the crossing to Kolb r.o.w. The current ramp design does not work as per detail 6/6, there is no room for a 4' landing at the top of the ramp. 2. Reference zoning comments for determination of relief from connection to rest of center. |