Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS09-18
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/26/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
| 06/26/2009 | MPADILL1 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS09-18 2740 W. Goret Rd. (X) Tentative Plat (grading plan, sheet 4 of 5) ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment () Other - Site Plan CROSS REFERENCE: C9-04-22 & DS07-11 AREA/NEIGHBORHOOD PLAN: Tucson Mountains Subregional Plan Map Detail 1 SCENIC ROUTE: Yes COMMENTS DUE BY July 02, 2009 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions (X) Proposal in Substantial Compliance with Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: REVIEWER: msp 791-4505 DATE: June 26, 2009 |
| 06/26/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 06/29/2009 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | Use of thickened edge, rather than header as per SD 213, is conditional upon the following: "This approval applies only to those areas outside of public right-of-way. Use of thickened edge is not permitted within the public right-of-way unless such approval is first granted by the TDOT Engineering Division" Also, there are additional changes to the plans that are not subject to the DSMR application. The applicant should discuss these changes with Jason Green of PADS to determine if these can be a Tier 1 grading plan revision or if they must be a Tier 2 revision. |
| 06/30/2009 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-09-18 2740 W Goret Rd. Las Nubes Subdivision Development Standard Modification Request (To use an asphalt thickened edge versus a concrete deader) Transmittal date: June 30, 2009 COMMENTS: Approved with conditions 1. Zoning supports the proposed thickened edges on all private streets. Approval or support for thickened edges on any public street is not supported unless TDOT approves the proposal. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 07/07/2009 | ANDY VERA | ENV SVCS | REVIEW | Approved | No objections in relation to solid waste disposal requirements. |
| 07/14/2009 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approv-Cond | TDOT-Traffic and TDOT-Engineering does not approve the use of thickened edge asphalt in lieu of concrete headers along public roadways, but the use of thickened edge on private roadways and private driveways is acceptable to TDOT-Traffic and TDOT-Engineering. |
| 07/15/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES July 15, 2009 Jeff Stanley Stanley Engineering & Drainage, Inc. P.O. Box 1888 Tucson, Arizona 85702 Re: DSMR 09-18 - 2740 West Goret Road (S06-050) Request: DS 3-01.3.2 - Modify Development Standards to allow thickened edge concrete along the pavement edge of rights-of-way instead of a concrete header. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions: 1) This approval applies only to those areas outside of public rights-of-way. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTAITVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax 792-0318 |