Permit Number: DS09-16
Parcel: 14019010A

Address: Unknown

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS09-16
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/09/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/09/2009 RONALD BROWN ZONING HC SITE REVIEW Approved
06/10/2009 MARTIN BROWN FIRE REVIEW Approved
06/11/2009 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section
PROJECT: DSMR-09-16
5418 S Park Avenue
Blue Sky Subdivision
Development Standard Modification Request

Transmittal date: June 11, 2009

COMMENTS: Approved with conditions

1. Zoning approves the DSMR request pending approval of the DMSR by the DSD Engineering and Landscape Review Sections.

2. An accessible pedestrian path must be provided from the street sidewalk to the human activity areas. This path must comply with any applicable ADA requirements.





If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
06/11/2009 DAVID RIVERA ZONING REVIEW Approv-Cond The DSD Landscape Section recommends approval of the application subject to the following conditions:

Provide revised landscape and grading plans that address how the proposed basin meets the intent and purpose of the applicable standard while accomodating human activity areas and associated access. The intent of the standard is to encourage grading solutions that reflect the same concern for proportion and aesthetics as with decorative landforms. The standard states that slope grading should achieve a balance between engineering functions, multi-use factors, and visual attractiveness and that slope, in general, is among the principal considerations of retention/detention basin visual quality.

The revised landscape plan must be updated to correspond with the grading plans, include additional groundcover and shrub plantings within the basin and additional groundcover plantings along Ray Clarke Loop to improve the visual interest of the basin and mitigate the visual impact of the rip-rap slopes. Alternatively, variation can be created in the basin slopes through the use of texture, color, and plantings. A more natural appearance can be achieved by establishing native seeds in soil covered rip-rap (if non-grouted) above the high water line or integrating colored stones, boulders, and concrete structures.
06/15/2009 JOSE ORTIZ TRAFFIC TRAFFIC Approved
06/17/2009 MATT FLICK ENGINEERING REVIEW Approv-Cond Basin sideslopes and building setbacks shall meet the recommendations contained in the geotechnical reports and any addenda thereto.
06/19/2009 ANDY VERA ENV SVCS REVIEW Approved ES has no objections to this request as it pertains to solid waste disposal requirements.
06/25/2009 JHERSHE1 COMMUNITY PLANNING REVIEW Approved Updated comments, 6/25/09

The plans are approved. Based on an email from Joseph Linville, he is requesting that basin side slopes be changed from 8:1 to 2:1 rip-rap. Although 2:1 rip-rap is not pedestrian accessible, the mainenance access ramps (as shown on the TP) are, and will provide sufficient access to the recreational facilities in the basins.

- Joanne Hershenhorn, 6/25/09


CDRC Review
Department of Urban Planning and Design, Development Review Section
DS09-16, 5418 S. Park Ave, 1st submittal
Comments Due: 6/16/09
Comments Submitted: 6/12/09

Items reviewed: Site Plan, DSMR request
Related: S07-085, Blue Sky, L. 1-42, RCP
(no associated rezoning case)

Comments: No objection to granting the DSMR.
Reviewed by: J. Hershenhorn, 6/11/09


S:\CASE_REVIEW\DSMR\08-09\DS09-16.doc
06/29/2009 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

June 29, 2009

Chad Amateau
Grenier Engineering, Inc.
5517 East 5th Street
Tucson, Arizona 85711

Re: DSMR 09-16 - 5418 South Park Avenue (S07-085)

Request: DS 10-01.4.3.1 - Modify Development Standards to allow a basin that is deeper than three (3) feet to have a 2:1 slopes.


The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions:

1) An accessible pedestrian path must be provided from the street sidewalk to the human activity areas. This path must comply with any applicable ADA requirements,
2) Revised landscape and grading plans per Landscape comments,
3) Basin sideslopes and building setbacks shall meet the recommendations contained in the geotechnical reports and any addenda thereto.



PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE TENTATIVE PLAT WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE TENTATIVE PLAT, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK.

If you have any additional questions, please contact me at 837-4919.

Sincerely,

Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records
Fax 326-7508